Wireless Intruder Alaram System Specification
Micro-controller based
8 zones
Inbuilt GSM based speech and SMS dialer
8 zones programmable as delay, immediate, panic or fire
Separate remote key pad with 16x4 LCD display
18 key back lit key pad
Can attach up to 3 additional LCD display remote key pads
3 status LED – armed, power and dialing
Two user codes – master and servant
Part arm
Automatic arming
Automatic disarming
One day holiday programmable for automatic disarming feature
Can be operated through mobile or telephone line using DTMF instrument
Panel can be armed and disarmed through telephone
Code can be changed through telephone
Any 8 electrical devices can be switched ON or OFF through telephone
These electrical devices can also be switched ON or OFF through a remote key pad
Armed light output
Built in battery backup provision
Zone omitting facility
Silent arming
Night mode arming
Intrusion log with time and date
Dedicated panic, fire and quick arm keys
Silent dialing
Power failure indication
Blown fuse indication on LCD display
Non-volatile memory
Open zone indication on LCD display
Automatic re-arming after an intrusion
System goes into alarm state after three incorrect code attempts
Previous state (armed or disarmed) retained when panel is re-powered
Chime in zone number 1
Chime is programmable for each independent remote key pad
Distinct interrupted sounder output for fire alarm
Battery strength display with audio indication in case of low battery
GSM signal strength display
Walk test
Individual zone status is indicated on display
Independent entry delay time 2 to 255 seconds
Independent exit delay time 2 to 255 seconds
Sounder time 2 to 20 minutes
Multiple sounder outputs
In-built tamper switch
Main control station panel in elegant white ABS body
Remote key pad housed in sleek white ABS body with key pad cover
Wired Intruder Alaram System Specification
Micro-controller based
25 zones
16 zones programmable as delay, immediate, panic, part and staff
8 zones dedicated for wireless keyfobs & wireless panic switches
1 dedicated tamper zone
Secure code hopping technology
Onboard 16 button keypad
4 line back lit LCD display
All sensors are configured through easy and secure learning process
Wireless RF Key Fob with instant arm, delay arm, part arm, disarm and panic alarm buttons
Supervised sensors with periodic health check with control panel
Sensor low battery indication displayed on control panel
Automatic arming and disarming at pre-programmed times
Programmable weekly holiday for automatic disarming feature
Two user codes - master and staff
Part and Full arm modes for convenient daily use
Automatic re-arming in case of alarm at which point open zones will be bypassed
System goes into alarm state after three incorrect code attempts
Previous arm status (armed or disarmed) is retained when panel is re-powered
Distinct interrupted siren for fire alarm
Inbuilt battery backup for internal clock
Battery strength displayed on LCD screen with audio warning for low battery
Power failure, blown fuse, low battery indication on LCD display
Open zones are indicated on LCD display
Independent entry and exit delay times programmable from 2 to 255 seconds
Programmable sounder time from 2 to 20 minutes
3 status LEDs — armed, power and error
Inbuilt lithium battery pack
Can omit one or more zones
Night mode arming to convert delay zones into immediate zones
Intrusion log with time and date
Panic and Quick Arm keys
Non-volatile memory restores multiple programmable settings in case of complete power reset
24 hour active zones are bypassed if open after sounder automatically switches off
In-built tamper switches
Simple to install and program
Eye catching slim sleek design
Premium white ABS housing with aesthetic brushed stainless steel front panel
Wireless Intruder Alaram System Specification
Micro-controller based
8 zones
Inbuilt GSM based speech and SMS dialer
8 zones programmable as delay, immediate, panic or fire
Separate remote key pad with 16x4 LCD display
18 key back lit key pad
Can attach up to 3 additional LCD display remote key pads
3 status LED – armed, power and dialing
Two user codes – master and servant
Part arm
Automatic arming
Automatic disarming
One day holiday programmable for automatic disarming feature
Can be operated through mobile or telephone line using DTMF instrument
Panel can be armed and disarmed through telephone
Code can be changed through telephone
Any 8 electrical devices can be switched ON or OFF through telephone
These electrical devices can also be switched ON or OFF through a remote key pad
Armed light output
Built in battery backup provision
Zone omitting facility
Silent arming
Night mode arming
Intrusion log with time and date
Dedicated panic, fire and quick arm keys
Silent dialing
Power failure indication
Blown fuse indication on LCD display
Non-volatile memory
Open zone indication on LCD display
Automatic re-arming after an intrusion
System goes into alarm state after three incorrect code attempts
Previous state (armed or disarmed) retained when panel is re-powered
Chime in zone number 1
Chime is programmable for each independent remote key pad
Distinct interrupted sounder output for fire alarm
Battery strength display with audio indication in case of low battery
GSM signal strength display
Walk test
Individual zone status is indicated on display
Independent entry delay time 2 to 255 seconds
Independent exit delay time 2 to 255 seconds
Sounder time 2 to 20 minutes
Multiple sounder outputs
In-built tamper switch
Main control station panel in elegant white ABS body
Remote key pad housed in sleek white ABS body with key pad cover
Wired Intruder Alaram System Specification
Micro-controller based
25 zones
16 zones programmable as delay, immediate, panic, part and staff
8 zones dedicated for wireless keyfobs & wireless panic switches
1 dedicated tamper zone
Secure code hopping technology
Onboard 16 button keypad
4 line back lit LCD display
All sensors are configured through easy and secure learning process
Wireless RF Key Fob with instant arm, delay arm, part arm, disarm and panic alarm buttons
Supervised sensors with periodic health check with control panel
Sensor low battery indication displayed on control panel
Automatic arming and disarming at pre-programmed times
Programmable weekly holiday for automatic disarming feature
Two user codes - master and staff
Part and Full arm modes for convenient daily use
Automatic re-arming in case of alarm at which point open zones will be bypassed
System goes into alarm state after three incorrect code attempts
Previous arm status (armed or disarmed) is retained when panel is re-powered
Distinct interrupted siren for fire alarm
Inbuilt battery backup for internal clock
Battery strength displayed on LCD screen with audio warning for low battery
Power failure, blown fuse, low battery indication on LCD display
Open zones are indicated on LCD display
Independent entry and exit delay times programmable from 2 to 255 seconds
Programmable sounder time from 2 to 20 minutes
3 status LEDs — armed, power and error
Inbuilt lithium battery pack
Can omit one or more zones
Night mode arming to convert delay zones into immediate zones
Intrusion log with time and date
Panic and Quick Arm keys
Non-volatile memory restores multiple programmable settings in case of complete power reset
24 hour active zones are bypassed if open after sounder automatically switches off
In-built tamper switches
Simple to install and program
Eye catching slim sleek design
Premium white ABS housing with aesthetic brushed stainless steel front panel
Wired Intruder Alaram System Specification
Micro-controller based
25 zones
16 zones programmable as delay, immediate, panic, part and staff
8 zones dedicated for wireless keyfobs & wireless panic switches
1 dedicated tamper zone
Secure code hopping technology
Onboard 16 button keypad
4 line back lit LCD display
All sensors are configured through easy and secure learning process
Wireless RF Key Fob with instant arm, delay arm, part arm, disarm and panic alarm buttons
Supervised sensors with periodic health check with control panel
Sensor low battery indication displayed on control panel
Automatic arming and disarming at pre-programmed times
Programmable weekly holiday for automatic disarming feature
Two user codes - master and staff
Part and Full arm modes for convenient daily use
Automatic re-arming in case of alarm at which point open zones will be bypassed
System goes into alarm state after three incorrect code attempts
Previous arm status (armed or disarmed) is retained when panel is re-powered
Distinct interrupted siren for fire alarm
Inbuilt battery backup for internal clock
Battery strength displayed on LCD screen with audio warning for low battery
Power failure, blown fuse, low battery indication on LCD display
Open zones are indicated on LCD display
Independent entry and exit delay times programmable from 2 to 255 seconds
Programmable sounder time from 2 to 20 minutes
3 status LEDs — armed, power and error
Inbuilt lithium battery pack
Can omit one or more zones
Night mode arming to convert delay zones into immediate zones
Intrusion log with time and date
Panic and Quick Arm keys
Non-volatile memory restores multiple programmable settings in case of complete power reset
24 hour active zones are bypassed if open after sounder automatically switches off
In-built tamper switches
Simple to install and program
Eye catching slim sleek design
Premium white ABS housing with aesthetic brushed stainless steel front panel
Wired Intruder Alaram System Specification
Micro-controller based
25 zones
16 zones programmable as delay, immediate, panic, part and staff
8 zones dedicated for wireless keyfobs & wireless panic switches
1 dedicated tamper zone
Secure code hopping technology
Onboard 16 button keypad
4 line back lit LCD display
All sensors are configured through easy and secure learning process
Wireless RF Key Fob with instant arm, delay arm, part arm, disarm and panic alarm buttons
Supervised sensors with periodic health check with control panel
Sensor low battery indication displayed on control panel
Automatic arming and disarming at pre-programmed times
Programmable weekly holiday for automatic disarming feature
Two user codes - master and staff
Part and Full arm modes for convenient daily use
Automatic re-arming in case of alarm at which point open zones will be bypassed
System goes into alarm state after three incorrect code attempts
Previous arm status (armed or disarmed) is retained when panel is re-powered
Distinct interrupted siren for fire alarm
Inbuilt battery backup for internal clock
Battery strength displayed on LCD screen with audio warning for low battery
Power failure, blown fuse, low battery indication on LCD display
Open zones are indicated on LCD display
Independent entry and exit delay times programmable from 2 to 255 seconds
Programmable sounder time from 2 to 20 minutes
3 status LEDs — armed, power and error
Inbuilt lithium battery pack
Can omit one or more zones
Night mode arming to convert delay zones into immediate zones
Intrusion log with time and date
Panic and Quick Arm keys
Non-volatile memory restores multiple programmable settings in case of complete power reset
24 hour active zones are bypassed if open after sounder automatically switches off
In-built tamper switches
Simple to install and program
Eye catching slim sleek design
Premium white ABS housing with aesthetic brushed stainless steel front panel
Technical Specification
Voice Logger Specification
Audio Line can be utilised wherever continuous audio recording is required. The logger logs the analog audio signals from any equipment connected to it as 'line-in'. Xtend provides USB-based Audio Logger in 1/2/4/8/12/16 upto 256 ports and more.
This logger toolkit can be programmed in such a way that it initiates the logging immediately after a keypress. There are 4 ways in which Xtend Logger commences the recording process. They are:
Timed Recording:
Logs the audio everyday, especially, during a particular time schedule.
Voice Activated Recording:
Logs the audio when specific voice/words are recognised.
Continuous Recording:
Logs audio wherever 24x7 logging is needed.
Externally-triggered Recording:
Logs the audio, if and only if an external trigger occurs, such as a switch is turned on.
Just like the other models of Xtend Voice Logger, audio model is a passive logger that does not tamper with the voice quality or the signalling system. Again, no change is required in the existing system configuration to install this model of the logging system.
Apart from hardware, Xtend Voice Logging Solution software needs to be loaded to generate the reports and details of logging. For the same, we require an ordinary PC with 2+ GHz processor capability and atleast 80GB hard disk storage space to store the voice logs. Windows XP Professional/2000/2003 Server operating system with a minimum of 512 MB RAM is required for proper functioning of the system. A CD/DVD writer avails to store backups whereas a Network Interface Card serves to access remotely the browser-based interface.
Technical Specification
Voice Logger Specification
Audio Line can be utilised wherever continuous audio recording is required. The logger logs the analog audio signals from any equipment connected to it as 'line-in'. Xtend provides USB-based Audio Logger in 1/2/4/8/12/16 upto 256 ports and more.
This logger toolkit can be programmed in such a way that it initiates the logging immediately after a keypress. There are 4 ways in which Xtend Logger commences the recording process. They are:
Timed Recording:
Logs the audio everyday, especially, during a particular time schedule.
Voice Activated Recording:
Logs the audio when specific voice/words are recognised.
Continuous Recording:
Logs audio wherever 24x7 logging is needed.
Externally-triggered Recording:
Logs the audio, if and only if an external trigger occurs, such as a switch is turned on.
Just like the other models of Xtend Voice Logger, audio model is a passive logger that does not tamper with the voice quality or the signalling system. Again, no change is required in the existing system configuration to install this model of the logging system.
Apart from hardware, Xtend Voice Logging Solution software needs to be loaded to generate the reports and details of logging. For the same, we require an ordinary PC with 2+ GHz processor capability and atleast 80GB hard disk storage space to store the voice logs. Windows XP Professional/2000/2003 Server operating system with a minimum of 512 MB RAM is required for proper functioning of the system. A CD/DVD writer avails to store backups whereas a Network Interface Card serves to access remotely the browser-based interface.
Technical Specification
COSEC ARC One/Two-door Panel
IP Technology on Existing LAN/WAN
Industry Standard CAT5 and CAT6 Wiring
Installation near the Door Reduces Wiring and Improves Reliability
PoE Powers PANEL, Readers and Locks, no Need of Local Power Point or Backup
Neat, Elegant, Reliable and Easy-To-Maintain Installation
Distributed Architecture; Robust Security
Compact, Modular and Easy to Scale
Industry Standard DIN Rail Mounting
COSEC PANEL integrates up to 255 Door Controllers with interlinked value added features.
Centralized Management and Control using COSEC PANEL Web Pages from anywhere
Technical Specification
COSEC ARC One/Two-door Panel
IP Technology on Existing LAN/WAN
Industry Standard CAT5 and CAT6 Wiring
Installation near the Door Reduces Wiring and Improves Reliability
PoE Powers PANEL, Readers and Locks, no Need of Local Power Point or Backup
Neat, Elegant, Reliable and Easy-To-Maintain Installation
Distributed Architecture; Robust Security
Compact, Modular and Easy to Scale
Industry Standard DIN Rail Mounting
COSEC PANEL integrates up to 255 Door Controllers with interlinked value added features.
Centralized Management and Control using COSEC PANEL Web Pages from anywhere
Repeater Panel Specification
Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
Modular Construction, Serviceable.
Surface Mount Technology.
Battery polarity & deep discharge protection.
As per IS -15908: 2011 Standard.
16 X 2 Dot Matrix LCD Display.
Standby battery backup with built in charging.
Fire / Fault status in unambiguous colored LED indication.
Switch Mode Power Supply.
Tactile Keypad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility
Zone wise one man walk Test Facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all type of Conventional Detectors.
Optional Zone Wise Sounder / Zone Wise Contact.
Repeater Panel Specification
Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
Modular Construction, Serviceable.
Surface Mount Technology.
Battery polarity & deep discharge protection.
As per IS -15908: 2011 Standard.
16 X 2 Dot Matrix LCD Display.
Standby battery backup with built in charging.
Fire / Fault status in unambiguous colored LED indication.
Switch Mode Power Supply.
Tactile Keypad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility
Zone wise one man walk Test Facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all type of Conventional Detectors.
Optional Zone Wise Sounder / Zone Wise Contact.
Feature
☆ Two loop addressable fire detection panel packed with features not usually associated with smaller systems, providing a high quality solution at exceptionally good value☆ Loop capacity 477 intelligent devices☆ 30 logical configurable zones☆ PAS and Acknowledge Function☆ Duplicate address report☆ Mismatch device type report☆ Dirty Detector Reporting☆ One Man Test Function☆ Graphical LCD Display☆ Zone indication and manual intervention panel☆ Net-workable with all GST intelligent fire panels☆ Programmable from PC☆ Built-in RS485 repeater output (Maximum 10 repeaters)☆ Optional GMC graphic station☆ Optional Panel Printer☆ Advanced user friendly programming software including ‘Fuzzy Logic’☆ Optional protection of re-programming☆ Approved by LPCB
Feature
☆ Two loop addressable fire detection panel packed with features not usually associated with smaller systems, providing a high quality solution at exceptionally good value☆ Loop capacity 477 intelligent devices☆ 30 logical configurable zones☆ PAS and Acknowledge Function☆ Duplicate address report☆ Mismatch device type report☆ Dirty Detector Reporting☆ One Man Test Function☆ Graphical LCD Display☆ Zone indication and manual intervention panel☆ Net-workable with all GST intelligent fire panels☆ Programmable from PC☆ Built-in RS485 repeater output (Maximum 10 repeaters)☆ Optional GMC graphic station☆ Optional Panel Printer☆ Advanced user friendly programming software including ‘Fuzzy Logic’☆ Optional protection of re-programming☆ Approved by LPCB
Hooter For Fire Alarm System Specification
Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
Modular Construction, Serviceable.
Surface Mount Technology.
Battery polarity & deep discharge protection.
As per IS -15908: 2011 Standard.
16 X 2 Dot Matrix LCD Display.
Standby battery backup with built in charging.
Fire / Fault status in unambiguous colored LED indication.
Switch Mode Power Supply.
Tactile Keypad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility
Zone wise one man walk Test Facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all type of Conventional Detectors.
Optional Zone Wise Sounder / Zone Wise Contact.
Hooter For Fire Alarm System Specification
Ravel Indian Manufacturer, International standard.
Switch Mode Power Supply.
Modular Construction, Serviceable.
Surface Mount Technology.
Battery polarity & deep discharge protection.
As per IS -15908: 2011 Standard.
16 X 2 Dot Matrix LCD Display.
Standby battery backup with built in charging.
Fire / Fault status in unambiguous colored LED indication.
Switch Mode Power Supply.
Tactile Keypad for easy panel operation.
System on indication.
Main, Standby status indication.
Low Battery visual warning with audible tone.
Relay output for actuators for Fire and Fault.
Lamp Test facility
Zone wise one man walk Test Facility.
Zone wise Isolation facility with loop voltage cut off.
Compatible to all type of Conventional Detectors.
Optional Zone Wise Sounder / Zone Wise Contact.
Product Description:
Aiming to satisfy our clients, optimally, we provide to our clients with a quality accepted array of FAAC Flap Barrier. Offered barriers are manufactured by our capable professionals, using the best possible quality material and the most modern technology in accord with the specifications of our clients. Also, these barriers are well checked on a range of quality parameters to guarantee their quality attributes.
Product Details:
1. Flap barrier is designed to control pedestrian entering or exiting restricted areas, with Stainless steel ,Outdoor weather Resistant for both indoor and outdoor installation.2. Flap barrier consists of cabinet, reader module, main control module motor driver module infrared photocell alarm device limit switch and voice prompt device etc., can be used for the applications like office building, hotel,apartment, museum, factory, station and ferry terminal etc.. Together with intelligent card reader/writer and management software, they are combined as intelligent speed gate management system, can fulfill the functions like entrance control, time attendance, pedestrian volume control and tolling etc.3. Smartcard reader compatible with a variety of card such as IC and ID card.4. International standard electrical interface, can be easily integrated with other R/W device Clear LED arrow direction indication.5. Counting function with record of the passing times and the records can be cleared up from menu.6. Infrared photocell for safety & for alarming unauthorized entry.
Features:
Excellent quality
Flawlessly finished
Enhanced durability
Advanced Sensor System
Audible and visible alarm
Fire alarm integration
Optional counter
Flap release when power off (optional with backup battery)
Flexible reader installation plate
Product Description:
Aiming to satisfy our clients, optimally, we provide to our clients with a quality accepted array of FAAC Flap Barrier. Offered barriers are manufactured by our capable professionals, using the best possible quality material and the most modern technology in accord with the specifications of our clients. Also, these barriers are well checked on a range of quality parameters to guarantee their quality attributes.
Product Details:
1. Flap barrier is designed to control pedestrian entering or exiting restricted areas, with Stainless steel ,Outdoor weather Resistant for both indoor and outdoor installation.2. Flap barrier consists of cabinet, reader module, main control module motor driver module infrared photocell alarm device limit switch and voice prompt device etc., can be used for the applications like office building, hotel,apartment, museum, factory, station and ferry terminal etc.. Together with intelligent card reader/writer and management software, they are combined as intelligent speed gate management system, can fulfill the functions like entrance control, time attendance, pedestrian volume control and tolling etc.3. Smartcard reader compatible with a variety of card such as IC and ID card.4. International standard electrical interface, can be easily integrated with other R/W device Clear LED arrow direction indication.5. Counting function with record of the passing times and the records can be cleared up from menu.6. Infrared photocell for safety & for alarming unauthorized entry.
Features:
Excellent quality
Flawlessly finished
Enhanced durability
Advanced Sensor System
Audible and visible alarm
Fire alarm integration
Optional counter
Flap release when power off (optional with backup battery)
Flexible reader installation plate
24 Vdc electromechanical barrier for intensive use with control panel with 433.92 MHz radio receiver and integrated battery charger.
Power range switching extended from 100 to 250 Vac, 50/60 Hz to reduce standby power to a minimum.
Control panel with LCD display. Possibility of self-testing the parameters and checking the condition of the safety devices (photo test). Compatibility with Advantouch device.
Option to install FTC.S photocells using concealed system so that they are perfectly integrated.
Integrated absolute encoder, which ensures greater precision in slowdowns and advanced control of the boom movement so that it never loses the reference position of the boom even if there is a power cut or the automatic device is released
Integrated STC System for precise torque calculation.
Serial connection with SIS accessory data sheet, for fast and easy connection for operation in paired boom mode.
Fast-acting release.
Integrated flashing lamp (requires EVA.LAMP accessory data sheet)
24 Vdc electromechanical barrier for intensive use with control panel with 433.92 MHz radio receiver and integrated battery charger.
Power range switching extended from 100 to 250 Vac, 50/60 Hz to reduce standby power to a minimum.
Control panel with LCD display. Possibility of self-testing the parameters and checking the condition of the safety devices (photo test). Compatibility with Advantouch device.
Option to install FTC.S photocells using concealed system so that they are perfectly integrated.
Integrated absolute encoder, which ensures greater precision in slowdowns and advanced control of the boom movement so that it never loses the reference position of the boom even if there is a power cut or the automatic device is released
Integrated STC System for precise torque calculation.
Serial connection with SIS accessory data sheet, for fast and easy connection for operation in paired boom mode.
Fast-acting release.
Integrated flashing lamp (requires EVA.LAMP accessory data sheet)
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Established in year 1994, as OBM then get upgraded to OBM AUTOMATION PVT. LTD. in the year 2007 acknowledged as the prominent wholesaler, supplier and service provider of Security and Telecom Products from last more than 2 decades. We constantly strive to achieve the highest possible standards in the quality of the products and services we provide with efficient team of trained professionals. WHY OBM Over 25 years of experience. PAN INDIA Service Prompt and Reliable Service Excellent Technical Knowledge