  • Eagle Analog I/O Modules

    Eagle Analog I/O Modules

    Get Price Quote

    • Power+ 24V DC ± 5%, 3.5W maximum
    • Operating Temp.0º to 50º C
    • Storage Temp.-20º to 80º C
    • Humidity10% to 90% (Non Condensing)
    • MountingDIN rail or back panel mounting
    • Dimensions Eagle-0404, Eagle-800 Eagle-0201-0302155 mm x 102 mm x 48 mm 94 mm x 42 mm x 47 mm
    • Immunity to ESD8kV Air, 6kV contact as per IEC 61000-4-2
    • Transient Immunity2kV as per IEC61000-4-4
    • Radiated Immunity10V / meter as per IEC61000-4-3
    • EmissionAs per EN55011 CISPR A
    • IsolationAnalog section isolated from digital. No isolation between channels.
    • IBM PortConnects to PC for application download or operator interface for Pass-through.
    • PLC PortConnects to PLC
    • Response TimeDepends on driver (Typical 200 mSec / Channel)
    •  Features DIN Rail or Panel mounted compact I/O modules Indication for Diagnostics, Power and Communication Adds I/O capability to your PLC, SCADA and Modbus networked devices Programmable inputs allow same modules to accept RTD, mA, mV 12 bit 8 universal analog inputs or with 4 Universal Analog inputs and 04 analog outputs Direct connection to PLC programming terminal with support for most PLCs Can be multidropped as Modbus Slave on RS485 Network Common Programming software for the entire Eagle family.........FREE!! CE marked Specifications For Voltage inputs  Uses 0-100 mV input range resolved in 12 bit. For higher input ranges, use externally calibrated shunt or contact factoryTotal error: ± 0.1% of scale ± 1 bit. For Current inputs Uses 0-20 mA input range with 5 ohms precision shunt resolved in 12 bit. Total error: ± 0.1% of scale ± 1 bit. For RTD inputUses 3 wire compensation technique. Current sense is 0.5mA Max. Power dissipated in RTD is 0.025 mV @ 100 ohms. Range supported: -200 to 850ºC For Thermocouple inputUses 0-100 mV input range resolved in to 12 bit for positive input and resolvedin 11 bit for negative inputs. Cold junction error is + 1º maximum and 0.5º typical. Total error: ± 0.5% of scale ± 1 bit + CJC error  Basic Eagle Operations Eagle units accept universal field inputs (such as RTD, T/C, mA, and mV) and convert them to actual field values like temperature, pressure etc. before sending them to the PLC. Similarly it can also read values in PLC registers and scale the 4-20mA output accordingly.Input and Output channels of Eagle are user configurable and any combination of input types is possible. Eagle Setup Software helps the user to configure the Eagle units and use them as per his requirements.Linearisation: 16 point linearisation is provided for mV and mA inputs, which helps the user to convert non-linear segments into required engineering value.Eagle units have two Communication Ports. Port1 (RS232/485) is connected to PLC and Port2 acts as Programming or Slave Port. Any Prizm model can be connected on Port 2 as a HMI.   Items required for Eagle configuration: Eagle unit + 24V DC regulated power supply IBM Cable (Part codes: IBM 0909-1 or IBM 0925-1) Eagle Setup Software Eagle to Device cable  System requirements for Eagle Setup Software are: Window version -  Microsoft Windows 3.1 or higher Processor -  386 or higher Hard Disk Space -  3 MB or more Mouse -  Required RAM -  2 MB or Higher Display Resolution -  640 x 480 (VGA) or better Display colors -  16 colors or more
    ...more
  • Analog IO Module

    Analog IO Module

    Get Price Quote

    analog io modules are devices that are Input Output to a SCADA. Inputs are Temperature, Pressure, Flow rate, Humidity, Level etc called as Analog Inputs. Inputs from Flow switches, level switches, Pressure switches, Proximity switches, Limit switches, auxiliary contact of contactor etc are called Digital Inputs.