Fire Hydrant Pumps Dealers in Pune (23 products available)

  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Being one of the oldest but yet the most effective and common fire fighting solutions , as well designed and laid out Hydrant system forms the backbone of the entire  fire fighting system.We are highly acknowledged as the best Service Provider of Hydrant System Fire. It is highly demanded in various buildings or premises, widely used for fire fighting solutions and helps in controlling fire during an emergency. This system is designed to suppress the fire and provide a readily available source of water to any point. Under the supervision of our team of well-trained professionals, the offered system is installed by using the modern tools & techniques and quality-tested components. Apart from this, we are offering the Hydrant System Fire in different specifications at affordable prices.The fire hydrant systems are access points that allow fire authorities to connect hoses and quickly disperse large amounts of water to extinguish flames.The system mainly consists of by a number of components & accessories like Fire pumps ( Jockey Pump, Electric Driven Pump, & Stand-by Diesel driven pump) Fire pumps are usually housed in a pump room very close to the fire tanks. The key thing is that the pumps should be located at a level just below the bottom of the fire tank, so that all the water in the tanks can flow into the pumps by gravity.Like all important systems, there must be backup pumps in case the main pump fails. There is a main pump that is electric, a backup pump that is electric, and a second backup pump that is diesel-powered, in case the electricity fails, which is common. Each of these pumps is capable of pumping the required amount of water individually - they are identical in capacity.There is also a fourth type of pump called a jockey pump. This is a small pump attached to the system that continually switches on to maintain the correct pressure in the distribution systems, which is normally 7 Kg/cm2 or 100 psi. If there is a small leakage somewhere in the system, the jockey pump will switch on to compensate for it. Each jockey pump will also have a backup., The capacity of the pumps is decided by considering a number of factors, some of which are:the area covered by hydrants / standpipes and sprinklers The number of hydrants and sprinklers The assumed area of operation of the sprinklers The type and layout of the building Dry Rising Main (Dry Riser). A vertical pipe installed in a building for fire fighting purposes, fitted with inlet connections at fire engine access level and landing valves on various floors, which is normally dry but is capable of being charged with water usually by pumping from fire engine pumps. Dry rising mains are basically dry water pipes. The empty mains need to be charged with water through the breeching inlets by fire appliance. The dry rising mains should not exceed 60m to avoid excessive pumping pressure.Wet Rising Main (Wet Riser). A vertical pipe installed in a building for fire fighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves on various floors. Wet rising mains are constantly charged with water that provide the required flow rate and pressure for fire fighting and equipped with water storage capacity for a given duration of 60 minutes. The breeching inlets, which are usually provided at ground level, are meant for replenishing the water tank.The distribution system consists of steel or galvanised steel pipes that are painted red.  These can be welded together to make secure joints, or attached with special clamps.  When running underground, they are wrapped with a special coating that prevents corrosion and protects the pipe.   External (Stand Post Type Or Underground Type – Sluice Valve, Water Monitor)The amount of water in the fire storage tanks is determined by the hazard level of the project under consideration.  Most building codes have at least three levels, namely, Light Hazard (such as schools, residential buildings and offices), Ordinary Hazard (such as most factories and warehouses), and High Hazard (places which store or use flammable materials like foam factories, aircraft hangars, paint factories, fireworks factories). The relevant building code lists which type of structure falls in each category. The quantity of water to be stored is usually given in hours of pumping capacity. In system with a capacity of one hour, the tanks are made large enough to supply the fire with water for a period of one hour when the fire pumps are switched on.  For example, building codes may require light hazard systems to have one hour’s capacity and high hazard 3 or 4 hours capacity.  The water is usually stored in concrete underground tanks. It is essential to ensure that this store of water always remains full, so it must have no outlets apart from the ones that lead to the fire pumps. These tanks are separate from the tanks used to supply water to occupants, which are usually called domestic water tanks. Designers will also try and ensure that the water in the fire tanks does not get stagnant and develop algae, which could clog the pipes and pumps, rendering the system useless in a fire.Guidelines and approval for hydrant system are available from various national and international organizations like NBC, NFPA,TAC,IS,FM & Local Authorities.

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    We are involved in the manufacturing and supplying of highly efficient Fire Hydrant System. Only superior grade parts and components are used for the manufacturing of our Fire Hydrant System. Moreover, the production process is carried out under the supervision of experts and thus there are minimal chances of defects at buyer’s end. We offer Fire Hydrant System at market leading rates.

    more..
  • Best Deals from Fire Hydrant Pumps

  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    The hydrant system comprises of ac motor driven pump sets with all required accessories including valves, instrumentation and controls etc. complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent.

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Fire hydrant system manufacturer and supplier in the market. Our fire hydrant system is manufactured with the use of the best quality components and materials ensuring superior performance and durability at the user end. We provide complete installation service for fire hydrant system. Made as per the approved industry standards, our fire hydrant system is well-tested by the experts for flawless functioning. applications industrial / non industrial buildingsinstitutional buildings residential apartments hotel & hospitals mall & multi storied complexes chemical & flammable storage yards

    more..
  • Fire Hydrant Pump

    Fire Hydrant Pump

    70,000 Per

    • Voltage: 220 to 380V
    • Material: Mild Steel
    • Frequency: 50 Hz
    • Working Pressure: 2.5 MPa
    more..
  • Fire Hydrant Pump

    Fire Hydrant Pump

    30,000 Per Piece

    1 Piece (MOQ)

    • Usage/Application: Fire Fighting
    • Type: Outdoor Fire Hydrant
    • Color: Red
    • Country of Origin: Made in India
    • Material: MS
    • Motor HP: 5 HP
    • Phase: Single Phase
    • Working Temperature: -5 To 55 Degree C
    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    we have gained huge respect for manufacturing and supplying Fire Hydrant Equipments. These equipments are precisely manufactured at our state-of-art manufacturing unit by making use of optimum quality LBT-2 & aluminum alloy materials and hi-tech equipments.

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Fire Fighting Hydrant System are used systems in residential and industrial projects to fight and prevent the spread of fire. A Red colour pipe of either Mild Steel or Galvanised Steel is used to circulate around the building or factory premise is known as a Fire Hydrant Pipe. In event of a fire, when you see a fireman shooting water up to 100 feet or more then the fire man is using a Fire Hydrant System. Such is the power of the Fire Hydrant System that water can be shot right up to directly into the fire.

    more..
  • Fire Hydrant Systems

    Fire Hydrant Systems

    Get Price Quote

    We provide a comprehensive range of fire hydrant systems that are commissioned on a turnkey basis. These fire systems can easily detect fire in the initial stage and can be controlled automatically by dialing to the fire brigade authority. These projects are handled by our qualified team of personnel, who have vast experience in their respective field. Highly cost effective, our range of systems is known for their reliability and durable performance. Further, we also consider the specific requirements of the clients while installing these systems

    more..
  • Fire Hydrant Pump

    Fire Hydrant Pump

    Get Price Quote

    • Color: Red
    • Type: Indoor Fire Hydrant, Outdoor Fire Hydrant, Rotating Fire Hydrant, Underground Fire Hydrant, Double Outlet Fire Hydrant
    • Material: MS, Cast Iron, GI
    • Minimum Order Quantity: 1 Unit
    more..
  • fire hydrant pumps

    fire hydrant pumps

    Get Price Quote

    • Usage/Application: Fire Hydrant System
    • Type: Outdoor Fire Hydrant
    • Color: Red
    • Brand Name: Efficient Fire
    • Power: 10-250 HP
    • Connection: Welded
    • Material: Cast Iron
    more..
  • Fire Hydrant Systems

    Fire Hydrant Systems

    Get Price Quote

    Fire Hydrant Systems, Alarm Systems, Fire Alarm Systems

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Fire Extinguisher Refilling, Fire Hydrant System AMC, fire hydrant pumps

    more..
  • Fire Hydrant System

    Get Price Quote

    utility piping services, Cooling Water System Engineering Service

    more..
  • Fire Hydrant Pump

    Get Price Quote

    Fire Hydrant Pump

    more..
  • Fire Hydrant System

    Get Price Quote

    more..
  • Fire Hydrant System

    Get Price Quote

    more..
  • Fire Hydrant System

    Get Price Quote

    fire hydrant system installation service, Fire Safety Equipment

    more..
  • Fire Hydrant System

    Get Price Quote

    Fire Detection System, Fire Hydrants, smoke alarm system, Fake Smoke Detector

    more..
  • fire hydrant pumps

    Get Price Quote

    fire hydrant pumps, Air Chain Hoist, Waste Heat Recovery Boiler

    more..
  • Fire Hydrant System

    Get Price Quote

    Mild Steel Pipes, Fire Hoses, Fire Detection System, Sprinkler, Pumps

    more..
  • Fire Hydrant System

    Get Price Quote

    more..
  • Fire Hydrant System

    Get Price Quote

    Hydrant System Contractor, Water Type Fire Extinguisher

    more..
Filter by Locality
top