  • TX 20 Industrial Single Channel Signal Isolator

    TX 20 Industrial Single Channel Signal Isolator

    Get Price Quote

    • MOQ10 Piece
    • TypeSignal Isolators
    • Dimension75 Mm (H) × 22 Mm (W) × 110 Mm (D)
    • Operating Temperature-20°C To 55°C
    • ModelTX-20
    • FeaturesSingle Input With Dual Isolated Outputs,Signal Conversion With Complete Electrical Isolation,Dedicated Input Type,High Accuracy: Better Than ±0.25% F.S.,Operates On 24V DC Supply,Compact And Maintenance-friendly Design,DIN Rail Mounting,Reliable And Cost
    • Accuracy±0.25% Of Full Scale
    • Isolation1.5 KV Between Input, Output & Power Supply
    • Power Supply24 V DC
    • Power Consumption< 4 VA
    • Response Time< 50 Ms
    • Temperature Coefficient±0.01% Per °C
    • EnclosureABS Plastic
    • WeightApprox. 250 G
    • Operating Humidity5% To 95% RH (non-condensing)
    • Signal Isolator — Model TX-20 Features Single input with dual isolated outputs Signal conversion with complete electrical isolation Dedicated input type High accuracy: better than ±0.25% F.S. Operates on 24V DC supply Compact and maintenance-friendly design DIN rail mounting Reliable and cost-effective solution for industrial signal conditioning   Description Electronet Series TX-20 signal isolators are designed for applications requiring a single input and dual isolated outputs. They accept dedicated current or voltage inputs and deliver isolated analog outputs in either current or voltage form. Its compact ABS enclosure ensures efficient use of panel space, while providing superior performance and electrical isolation.   Technical Specifications General No. of Inputs: 1 No. of Outputs: 2 Input Type (Dedicated) Current: 4–20 mA Voltage: 0–5 V / 1–5 V Output Type (Dedicated) Isolated Current: 4–20 mA Isolated Voltage: 0–5 V DC Accuracy ±0.25% of Full Scale Isolation 1.5 kV between input, output & power supply Power Supply 24 V DC Power Consumption < 4 VA Response Time < 50 ms Temperature Coefficient ±0.01% per °C   Mechanical Enclosure: ABS Plastic Dimensions: 75 mm (H) × 22 mm (W) × 110 mm (D) Mounting: DIN Rail Weight: Approx. 250 g   Operating Conditions   Temperature: –20°C to 55°C Humidity: 5% to 95% RH (non-condensing)
    ...more
    www
  • Signal Isolator

    Signal Isolator

    2,750 / Piece

    • Usage/ApplicationIndustrial
    • Brand NameGaurav Engineers
    • Operating Temperature0-55 Degree C
    • Power ConsumptionLess than 5VA
    • ProtectionConformal Coating on PCB
    • Enclosure MaterialABS
    • Power Supply20 to 265 V DC/AC, 45-65 Hz
    • Accuracy+/- 0.1% of FS
    ...more
  • Signal Isolators

    Signal Isolators

    Get Price Quote

    • Input0 – 20 / 4 – 20 mA
    • Supply230 V AC, ±10 %
    • ProtectionShort circuit inbuilt
    • MountingDIN Rail
    • Size65 x 70 x 110 (H)
    • ESD's signal isolators are suitable for connecting field signal from sensors to PLC's with isolated ground loop. These isolators prevent noise and RFI EMI interference being transmitted to the instruments.
    ...more
  • Signal Multiplier

    Signal Multiplier

    Get Price Quote

    • Brand NameProtocontrol Instruments
    • Protocontrol offers signal multipliers to isolate field signals like 4-20 ma and multiply them to up to four for processing them at four different locations. Hence one 4-20 ma input can be used for location indication, remote monitoring as well as data acquisition. These multipliers find use in process control industries for signal isolation. Variety of models is available for specific applications. in the field, many signals are generated such as motor current, armature voltage, position feedback in the form of change in resistance or signals obtained from various types of traducers in standard voltage or current form. these signals are not isolated from input and not suitable for transmission over long distance. Converters are specially developed to overcome these problems in transmission such as line drop, interference, ground looping, non compatibility to standard processing unit. salient features includes complete galvanic isolation between input output and control supply , independent zero and span adjustments ,stable current output eliminates need for special cable, shielding, signal multipliers are housed in din rail mounting engineering plastic enclosure, special robust cast al. Enclosures suitable for field mounting are also available. these multipliers are extensively used in cement, fertilizer, chemical, and processing plants.
    ...more
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    • Number Of FlowerSignal Isolators
    • Connectivity TypeWireless
    • Packaging TypePacked in corrugated boxes
    • Total Carbohydrate6 Months
    • Transmitter power24 V DC for current inputs
    • Isolators & Signal Conditioners Single Input Dual Output(DIN 1X2) Signal Isolation Transmitter LOW COST INTERNALLY POWERED ISO-UPO: DC Voltage Signal (VI, VV) Isolated Amplifier IC DIN 1X1 VF Transmitter
    ...more
  • Signal Isolators and Converters

    Signal Isolators and Converters

    Get Price Quote

    • Din Rail mounted signal converter / isolator is available in different input.• 0-5mVDC / 0-20mVDC / 0-50mVDC / 0-100mVDC / 0 10mADC / 0-20mADC / 4-20mADC / 0-5 VDC / 1-5 VDC / 0-10VDC / 0-5Amp / 0-1 Amp or    customer specified, up to 3 outputs are available with all port isolation i. e. supply to input / supply to output / input to output and output to    output channel isolation.• Unit is available in 24VDC, 110VAC and 230VAC supply.  
    ...more
  • Signal Isolators / Coniditioners

    Signal Isolators / Coniditioners

    Get Price Quote

    • Input0/4-20 mA, 0/2-10 VDC, 0-75 mV, DC RTD ( Pt - 100 ) Thermocouple
    • Transmitter Supply24 VDC
    • Output0/4-20 mA or 0-10 VDC
    • Power Supply ( Isolator )230/110 VAC, 24 VDC
    • Power Supply ( Trans. )12-32 VDC / 30 mA
    • AccuracyBetter than ± 0.2 % of FS
    • Mounting35 mm DIN Rail mounted
    • Features : • Front Calibration Facility• Three Port isolation in Isolators• High Optical isolation in Isolators• Long term stability• Single / Multi input & output option• Compact sizes for many no. of input / output• 24 VDC operated 2 wire transmitter for various inputs  
    ...more
  • Signal Isolators

    Signal Isolators

    Get Price Quote

    • Input0 – 20 / 4 – 20 mA
    • Output0 – 20 / 4 – 20 mA
    • ESD's signal isolators are suitable for connecting field signal from sensors to PLC's with isolated ground loop. These isolators prevent noise and RFI EMI interference being transmitted to the instruments.
    ...more
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    • Usage/ApplicationIndustrial
    • Brand NameUL Automation
    • Input Voltage24VDC
  • Isolated AC Transmitter

    Isolated AC Transmitter

    Get Price Quote

    • Number Of FlowerTransmitter
    • Current TypeAC
    • Power SourceElectric
    • Pack typeCarton box
    • UsageIndustrial
    • Presenting high quality Isolators manufactured using the top grade material and advanced technology. Our products are known for their durability and longer equipment life, and we make sure our products are always up to the mark of our clients requirement. We are one of the best known and trusted manufacturers, exporters and suppliers of Isolators all over the country. These Isolators are available with us at reasonable market prices.
    ...more
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    • INPUT 0/4 to 20 mA DC or 0/1 to 5 V DC O to 10 VDC,Pt 100 T/C
    • OUTPUT 0/4 to 20 mA DC O to lO VDC
    • INPUT Less than 100 V for 4 to 20mA
    • IMPEDANCE >100kforOto10VDCi/p
    • OUTPUT LOAD 500 V Max. for 4 to 20 mA
    • INPUT-OUTPUT 2 kv DC FOR 60 sec.
    • ISOLATION ACCURACY LINEARITY OUTPUT 0.25% of F. S. 0.25% of F. S. 28 mA max.
    • CURRENT LIMIT ZERO-SPAN ADJUSTMENTS By multiturn trimpot
    • OUTPUT 24 VDC, 50 mA optional
    • OPERATING TEMP 10 to 50 °C
    • OPERATING HUMIDITY 90% Rh N. C. max.
    • TEMPERATURE DRIFT 200 ppm
    • DIMENSIONS MOUNTING Wall Mounted type DIN rail Mounting.
    • WEIGHT MODEL 1.5Kgapprox. 405 - Dual output with DIN rail housing 406 - Dual output wall mounted type with 24 v DC output 407 - Five output with DIN rail housing.
    • GENERAL DESCRIPTION Signal isolators are used to provide isolation between both field DC signals and final control element. The instrument provides 1.5 KV DC galvanic & opto isolation between the input signal & output signals. These instruments accepts 0/4 to 20mA singal proportional to input.The high accuracy, linearity & very low temp. drift is the added feature. The instrument is housed in a std DIN rail housing with zero, span adjustments are user accessible. The instrument in packaged in plastic DIN rail also suitable for wall mounting. 24v DC output is optional to power field transmitters. Dual I/P & Dual 0/P version available. Also 8 I/P and 8 O/P version in DIN rail mounting available. Any I/P & O/P configuration as per system requirement can be given.     FEATURES   Eliminates ground 100 P problems. Duel l/P-Dual O/P, Four I/P- Four O/P versions available. Also 81/P-8O/P version available. All I/P-I/P, I/P-O/P & O/P-O/P isolation (Threeport isolation)    
    ...more
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    Signal Isolator, Alarm, Scanners, Transducer
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    Signal Isolator, Ethernet Converter, USB Bidirectional Converte
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    Adept is one of the leading manufacturing & supplying company of high quality signal isolator in india.
  • Signal Isolator

    Signal Isolator

    Get Price Quote

    Signal Isolators are used to isolate DC signals and provides a repeater signal with isolation between input, output and the instrument’s power supply. Use of Signal Isolatorsrepeaters prevent ground loop problems in complex control loops involving multiple grounds, loop-powere bulk supplies in 2-wie systems, unisolated cards in PLCs etc.