Water Purification Plants Dealers in Kothrud, Pune (42 products available)

  • Reverse Osmosis System

    Reverse Osmosis System

    Get Price Quote

    We are instrumental in bringing to clients high performing Reverse Osmosis System. The Reverse Osmosis System helps in water purification and thus maintains the drinking water quality. We are into supplying different range of Reverse Osmosis System all over the world. Customers can obtain the Reverse Osmosis System at market leading rates.

    more..
  • Industrial Water Pump

    Industrial Water Pump

    Get Price Quote

    The cooling system of the engine (V92S2 & V46) is of a closed, high temperature type, with forced circulation and ejection cooling radiators. The system provides for dissipation of heat from the engine parts containing hot gases and maintains their temperature within permissible limits. The coolant used is water.Used on : T90, T72 tanks.

    more..
  • Best Deals from Water Purification Plants

  • Transformer Oil Filtration Plant

    Transformer Oil Filtration Plant

    Get Price Quote

    Our oil filtration plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other gases. This is a `low temperature and high vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 1200 to 25,000 lph which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60°c it passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.   High-Vacuum Transformer Oil Filtration and Dehydration Plants Our Oil Filtration Plants are used to remove impurities from transformer and switchgear oil such as moisture, dirt, air and other dissolved gases. This is a `Low Temperature and High Vacuum` principle based equipment as per the International Standards 6034 (1989) and its latest revision. We manufacture plants of variable capacities of 600 to 25000 LPH which can be customized to special capacities if required by the clients. This plant takes the impure oil into the system through the inlet ball valve and then pumps it through by a positive displacement pump. A filter prior to this removes solid particles up to 1mm size and magnetic particles. After heating the oil up to 60°C t passes through the cartridge filters, where particles up to 5 microns are filtered. A specially designed vacuum chamber removes moisture, air and all the gases with the help of vacuum. The oil falls by way of gravity over the media inside forming a thin film of oil, exposing a larger surface area. The dissolved moisture and gases are evacuated and the oil is ready.   Transformer Oil Filtration and Dehydration Plants / Purifiers are available for Transformer and Capacitor Manufacturers – Skid mounted plants for preparation of new oils prior to apparatus filling and impregnation. Transformer Repairers - Complete plants for preparation of new oils and regeneration of used oils for reuse. We can provide the purification system you need as well as vacuum storage tanks and transformer filling and emptying / pumping station. Transformer Owners - Portable plants are available in a variety of trailer-types and sizes to allow on-site servicing of transformer oil right in the substation. Trailers are available with a wide variety of options including laboratory space, oil-testing equipment. Plants are designed for drying out of the transformer insulation and oil filling and impregnation under vacuum. Hot oil circulation and hot oil spray methods can also be used. The filtration plant will be designed for high vacuum & low temperature of oil for achieving required results.The plant will be Mobile, to be mounted on your Vehicle or Skid Mounted, with or without enclosure, suitable for outdoor or indoor use.All components will have adequate strength & rigidity to withstand normal conditions of handling & transport.   The plant will consist of the following : Inlet Pump   A 600 to 25000 LPH capacity positive displacement gear type pump will be provided. The pump will be suitable for vacuum & continuous trouble free operation. A pressure release valve will be provided across the gear pump, to control the accidental pressure rise in the plant.   Capacity – 600 to 25000 LPH Operating Pressure - 2 Bar Suction - 4-5 mtrs By pass arrangement will be provided in between Inlet & Outlet   Heaters   Nicrome or Kanthal wire heater elements inserted in refractory formers will be provided in protection tubes to avoid localized overheating, hot spot formation & breaking of oil. Heaters will be capable of heating oil from 200 C. to 600 C., as recommended in IS 6034 – 1989. Total heater power will be 9 to 248 kW divided into two/three groups. Each group of heaters will be controlled by TIC. An additional thermostat will be provided as a safety to control the temperature during accidental temperature rise.The surface density of the heater pipes will not be more than 2.5 watts/cm2.A drain valve for the heater tank will be provided.   Indirect type, Wound elements placed in ceramic formers located in Protection Tubes. Heater Power : 9 to 248 KW. A Pressure Safety Valve & a Drain Valve will be provided. A Control Thermostat and a Safety Thermostat will be provided.   Filtration System   Filtration system will consist of the following,   A Preliminary filter   This filter will be provided to prevent any damage to inlet pump by straining magnetic & all other particles above 1mm size. The cleaning of the filter is possible without dismantling the filter from the pipeline.   Cleanable without dismantling   Flow capacity – 600 to 25000 LPH Rating - 50 mm Arrests magnetic particles B Pre-Filter   Filters will be easily changeable. It will be suitable for removal of particles larger than 20 microns. It will be suitable for removal of sludge content in the used oil. This will enhance the life of fine filter. C Cartridge Filter (fine filter)   Throw away type, non-hygroscopic cartridge filter elements of one-micron rating will be provided. The cartridges are easy for replacement & have large dust holding capacity.   Cartridge Filter (fine) placed in a steel housing.   Flow capacity – 600 to 25000 LPH Rating - 1 Micron   Ionic Reaction Column   An Ionic Reaction Column of 10 to 40 Kg activated alumina will be provided for reduce the acidity in the oil. A bypass arrangement will be provide for after first filling with IRC.   Degassing Chamber (Single Stage as well as Two Stage)   It will be of M.S. welded construction. The chamber will be designed to withstand the suitable vacuum. In the degassing chamber, dissolved gases & moisture from the oil will be removed. A specially designed media will be provided in the degassing chamber to offer maximum surface area, to form a thin film of oil, to achieve maximum possible removal of dissolved gases & moisture at the rated flow rate. One high level & one low level float switch will be provided to control the oil level in the degassing chamber.   Two stages will be separated by a siphon seal.Highly efficient Two Stage degasser packed with Raschig Rings & equipped with the following :   Totally Welded Sight Glass & Lamp Shade Raschig Ring Trays Low Level and High Level Float Switches Level Sensor will provided in Degassing Chamber   Outlet Pump   A centrifugal pump will be provided at the outlet. The capacity of the pump will be 12000 LPH and it will be suitable for sucking oil from degassing chamber, held under vacuum.   Capacity - 12000 LPH. Discharge Head - 8 Mtrs   Vacuum Pumping System   A combination of roots & rotary vacuum pumps will be provided for evacuation of degassing chamber. An additional connection with an isolation valve will be provided in the system, to facilitate evacuation of transformer tank, simultaneously.The vacuum pumping system will be equipped with all-necessary accessories like Vapour trap, condenser, valves & gauges etc.The specifications of the vacuum pumps will be as follows:   Rotary Oil Sealed Pump Pumping speed (Minimum) Ultimate vacuum Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed   Mechanical Booster (Roots) Pump   Pumping speed (Minimum) Ultimate vacuum Make Indo Vacuum/Dicon/Tuthill/Leybold/Woo Sung/ Shinko Seiki/Reputed   The Vacuum System will be equipped with the following :   Vacuum Gauge (Bourdon Type), Range: 0 to -760 mm of Hg Vacuum Gauge (Digital Type), Range: 1 Torr Airing Valve Non return Valve   Cooling System   For cooling, a condenser will be provided in the vacuum line. A condenser will be provided, to maintain ambient temperature of the water which will be circulated through this condenser for collecting water in to the trap. One water tank will be provided in to the top of the mobile van having capacity to hold 100 liter water.   Non Return Valve   One non return valve will be provided at the inlet and one at the outlet, which will prevent mixing of filtered & unfiltered oil, in case of power failure.   Valve & Piping   Two airing valves will be provided for airing the vacuum system. All inline valves will be Ball Valve in case of Fully Automatic System then Valves will Solenoid Valves with carbon steel body & S.S. ball, suitable for vacuum application.   Oil & Vacuum Valves will be of Solenoid type or Ball Valve. Piping will be of Normal Steel. Mechanical Non Return Valves before Degassing Column & at Plant outlet Oil Sampling Valve Isolation Valve at Plant Inlet & Outlet   One pressure gauge at the inlet of the cartridge filter will be provided. One bourdon type vacuum gauge & one digital gauge (for measurement of fine vacuum) will be provided in the vacuum system.Independent electric drives will be provided for all pumps. Motors will confirm generally to is 325 (testing) & will be of CGL / Hindustan Motors / Siemens or any other reputed make. Starters will be of direct on line type.   Control Panel   The enclosure will be fabricated out of CRCA sheets & will be suitably coated to protect from weather. All electrical control gears, mains isolating arrangement, starters, contactors, pilot lamps, push buttons, HRC fuses, relays, indicating lamps and interlocking arrangements will be housed in the enclosure. All wiring will be neatly routed & all wire terminations will be suitably identified with ferrules.A tube light will be provided for plant illumination. The plant will be suitable for operation on 415 V, 3 Phase, 50 Hz. A.C. supply.Incoming Power Supply Cable for Control Panel is to be arranged by the Customer and is not included in scope of our supply.   Electrical Interlocks   The inlet pump will be interlocked with the heaters, in such a way that unless the oil is actually flowing in the system, the heaters cannot be energized. The electrical interlock between heater supply and motor supply will also be provided so that as soon as the inlet motor trip due to some fault in the drive/due to supply failure, the heater supply will also be automatically cut off. In case of power failures, electro magnetically operated inlet and outlet solenoid valves will be closed and prevent oil from entering the degassing chamber. The moment oil inlet pump or discharge pump is switched on the corresponding valves will open automatically. The suction pump and the level controller in the degassing chamber will be interlocked in such a way that when the oil/foam level in the degassing chamber increases beyond the desired level, the suction pump will be automatically cut off so that there is no further flow of oil in the degassing chamber. The temperature indicator of digital type, together with thermostat provided will automatically switch on/off the heater elements in groups so that temperature of the oil during treatment will not be permitted to rise above the pre-set value. A pre-set safety thermostat provided on the heater vessel will switch off all the heaters in case of any accidental temperature rise of the oil above safe temperature levels so that any likelihood of fire hazard is fully eliminated. The inlet gear pump will be provided with built in relief valve to take care of accidental pressure increase at the outlet side of the gear pump. An external relief valve will be provided on the heater vessel to take care of any accidental pressure rise above the safe level in the heater vessel.   Oil Hoses   Two numbers Nitrile Rubber Hoses each 10 to 15 Meters long with quick connect coupling end connection on both sides shall be provided. One is for inlet & one for outlet. Oil Hoses will be capable of handling the transformer oil at 135oC (max.) and hoses will be will be suitable for full vacuum operating conditions.   Lifting Hook   Lifting Hooks for Plant will be provided to facilitate ease of Plant Loading and unloading.   On Line Moisture Meter (As per clients requirement)   A panel mounted Digital Moisture (PPM) Meter will be provided in the outlet line to measure the moisture content in the oil.   Oil Flow Meter with Totalizer (As per clients requirement)   A panel mounted digital oil flow meter of Vatturkar / Inconel / reputed make will be provided in the outlet line to measure the oil flows.   Sleeping Arrangement (As per clients requirement)   A frame mounting arrangement for sleeping purpose of the operator will be provided in the mobile van on top of the heater tank. The bed will make from foam sheet and Rexene cover. Cooling fan will be provided in the rest room. Two persons easily sleep in to the rest bed.   Platform for Bike (As per clients requirement)   The platform will be provided for hanging bike in to the mobile van. The arrangement will be making as per your requirement and it will easy to handle in all situations.   Painting   A suitable anti rust primer will be applied on the interior and exterior surface of all steel parts, which shall followed by application of two coats of suitable durable paints to serve as base and binder for the finished coat. Under body of carriage will be painted with special black anti rust paint   Inspection Testing & Commissioning   Inspection & Testing of Transformer Oil Filtration Plant will be carried out by Consignee before dispatch.Commissioning will be done at site; our Engineer will be available on schedule date mutually decided by both parties.Our one person will be provided at your site to train and educate the operators for the period of one month. Site expenditure of the person will be at your scope.   Drawings & Manuals   One set of Schematic drawings & Guaranteed Technical Particulars of the Transformer Oil Filtration Plant will be provide with the offer and detail drawing with general arrangement of Filtration Plant, Electrical Wiring Diagram and User Manual will be provided at the time of supply.   Performance Guarantee   We give guarantee for performance of the Plant for a period of 12 months from the date of commissioning of the Plant or 18 months from the date of dispatch, whichever is earlier. During guarantee period we undertake upon written request of the purchaser to repair or replace at our discretion & as soon as possible any parts of goods delivered which can be proved to be damaged or unfit due to bad material, faulty design or poor workmanship. This guarantee does not cover damages resulting out of normal wear & tear, improper maintenance, failure to observe the operating instructions, incorrect operation, excessive loading, the use of unsuitable material, & other reasons beyond our control. This guarantee does not cover Consumables, Rubber Parts (including Oil/Vacuum Hoses) & Electrical Components-Motors.    

    more..
  • Reverse Osmosis Plant

    Reverse Osmosis Plant

    Get Price Quote

    REVERSE OSMOSIS:Reverse Osmosis is a well known process of Removal of TDS ( total Dissolved salts or Solids) from water.The Osmosis is very natural process  which everybody of us Knows.The Reverse Osmosis is achieved by applying ‘higher’ Pressure ( higher than Osmotic pressure Plus Losses and Backpressure of RO membranes) on feed water to so as to reverse the direction of natural osmosis (flow of water molecules from Low Concentration-Low Osmotic pressure side to Higher concentration- Higher Osmotic pressure side)The Osmotic pressure is directly proportional to the concentration of it ROT, 1000 ppm Concentration is 10 psig of osmotic pressure,We can visualize it as SUCTION pressure of relatively higher concentration Solution when two of them separated by Semipermeable Membrane. We make RO plants from 200LPH to 30,000 LPH and more.The general recovery of the brackish water RO plant is from 50% till 85%. Today RO is a keyword for most water purification applications from Domestic Drinking Water area to High Purity Boiler Water generation.

    more..
  • Hot Water Generators

    Hot Water Generators

    Get Price Quote

    • Brand Name: Eskimo Refrigeration Industries
    • Fuels: Diesel
    • Color: Customized
    • Voltage: 440V
    • Material: M.S.
    • Efficiency: Wood - 70 % / Diesel - 90 % / LPG - 80 %
    • Capacity: 15,000 Kcal/hr to 1,00,000 Kcal/hr
    • Size: Customized
    • Heater Material: M.S.Coils
    • Model Number/Name: ESKHWG
    more..
  • Packaged RO Plant

    Packaged RO Plant

    Get Price Quote

    • Type: Ro Plant
    • Weight: 1000-2000kg, 2000-3000kg
    • Voltage: 110V, 220V
    • Automatic Grade: Fully Automatic, Semi Automatic
    • Power: 1-3kw, 12-15kw
    • Driven Type: Electric
    more..
  • Raw Water Plant

    Raw Water Plant

    Get Price Quote

    Depending on water source (surface waterground water), water contains various impurities in the form of suspension as well as dissolved matter. Normally inorganic particles, colloids and biological debris such as microorganisms and algae are in suspensions and dissolved impurities consists of highly soluble salts, such as chlorides, and sparingly soluble salts, such as carbonates, sulfates, and silica etc.

    more..
  • Oil Filtration Plant

    Oil Filtration Plant

    Get Price Quote

    our filtration plants purify and upgrade transformer oil to comply with standard specifications. These plants can be designed as per customer’s specifications and are also available in varying capacities covering a whole range of applications in low, high and extra high voltage equipments. They perform the following functions:   removal of suspended impurities such as dust, rust, scales, colloidal carbon oxidation sludge etc. Up to < 1 micron.   degassing and dehydration of transformer oil with vacuum circulation of heated oil and filling of treated oil in transformer tank prevention of acid formation by evaporation and adsorption method

    more..
  • Industrial Mineral Water Plant

    Industrial Mineral Water Plant

    Get Price Quote

    We are offering mineral water plants.

    more..
  • aqua fresh water purifier

    aqua fresh water purifier

    5,499 Per Box

    1 वर्ष वॉरंटी व इन्स्टॉलेशन फ्री (ro+uv+tds+minral+sediment) 7 stage ro water purifier 12 liter storage capacity fully automatic 100 gpd membrane 100 gpd pump

    more..
  • Industrial Reverse Osmosis Plant

    Industrial Reverse Osmosis Plant

    160,000 Per unit

    • Material: MS And FRP
    • Automatic Grade: Automatic
    • Voltage: 220 V
    • Capacity: 1000-2000 Liter/hour
    • Frequency: 50 Hz
    • Phase: Three Phase
    • RO Capacity: 2000-3000 (Liter/hour)
    • Brand Name: Aquatech
    • Usage/Application: Water Purification
    • Power Source: Electric
    more..
  • Water Filtration Plant

    Water Filtration Plant

    455,000 Per

    • Automatic Grade: Automatic
    • Voltage: 440 V
    • Type Of Machines: Sand filter.carbon filter
    • Plant Application: Drinking
    • Frequency: 50 Hz
    • Material: SS Etc.
    more..
  • Water Treatment Plant

    Water Treatment Plant

    Get Price Quote

    We are the main supplier of this product.

    more..
  • Water Purifiers

    Water Purifiers

    44,900 Per Piece

    Blue Star, India’s leading air conditioning and commercial refrigeration company brings you Stella – the first Hot and Cold RO+UV water purifier in the country.

    more..
  • Water Treatment Plants

    Get Price Quote

    Waste Water Treatment Equipment

    more..
  • Reverse Osmosis System

    Get Price Quote

    Reverse Osmosis System, Water Filter

    more..
  • Water Treatment Plants

    Get Price Quote

    Activated Carbon Filter Plants, Solid Waste Treatment Plants

    more..
  • Reverse Osmosis Plant

    Get Price Quote

    more..
  • Waste Water Treatment Plant

    Get Price Quote

    Food Processing Equipment, Fly Ash Disposal System, Waste solid treatment

    more..
  • electric water purifier

    Get Price Quote

    Commercial Water Filter, five stage water purifier, Domestic Water Purifier

    more..
  • Water Treatment Plants

    Get Price Quote

    Water Softeners, UV Sterilizers, Micron Filters, Membrane Filter System

    more..
  • Ion Exchange Plants

    Get Price Quote

    Ion Exchange Plants, Pressure Sand Filter Plants, Solid Waste Treatment Plants

    more..
  • Filtration Plant

    Get Price Quote

    Filtration Plant, Solenoid Valves, RO Solenoid Valves

    more..
  • Water Treatment Plants

    Get Price Quote

    chemical toilets, Reverse Osmosis System, Mineral Water Plants

    more..
  • Marine Generators

    Get Price Quote

    Marine Generators, Stationary Fire Pump Engines, Commercial Mobile Generators

    more..
  • Water Purifiers

    Get Price Quote

    Water Purifiers, Glasswares

    more..
  • Water Treatment Plants

    Get Price Quote

    Boilers

    more..
  • Water Treatment Plant

    Get Price Quote

    Waste Water Treatment

    more..
  • Water Purifier

    Get Price Quote

    Dairy Equipment

    more..
  • Water Treatment Plant

    Get Price Quote

    more..
Filter by Locality
top