Earth Leakage Relay Dealers in Sangli

(3 products available)
  • Digital Earth Leakage Relay

    Digital Earth Leakage Relay

    Get Price Quote

    • Input Auxiliary Supply: 230 VAC (110 VAC & 415 VAC optional)
    • Trip Time: From 0.15 Seconds to 3.00 seconds settable with DIP switches
    • Relay Contacts: Potential free NO-C-NC, 10Amps at 250 VAC contacts

    Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. SYCON 770X Earth leakage Relay continuously detects the leakage current with the help of CBCT (Core Balance Current Transformer.) The CBCT is mounted externally. The current carrying cables (it may be 3 phase supply or 1 phase supply) are passed through the CBCT. CBCT detects the level of current and trip the device at set current & time. General Features Solid state Wide operating current range Low power consumption Variable current and time setting Ideal for compliance to I E rule 61-A

    more..
  • Earth Leakage Relay

    Earth Leakage Relay

    2,100 Per Units

    10 Units (MOQ)

    • Relay Type: Overload Relay
    • Brand Name: SYCON
    • Overall Dimension: 60(L) x 70 (W) x 110(D) mm
    • Current: 30mA to 8A
    • Trip Time Display Sec: 0.15 Seconds to 3.00 seconds
    • Power Supply: 230 VAC (110 VAC & 415 VAC optional)
    • Trip Indication: LED
    more..
  • Best Deals from Earth Leakage Relay

  • Earth Leakage Relay with Display

    Earth Leakage Relay with Display

    Get Price Quote

    1 Piece (MOQ)

    We are offering earth leakage relay with display order code current range tripping time sycon 7721 30 ma to 300 ma 0.15 sec to 3 sec sycon 7722 300 ma to 3 a 0.15 sec to 3 sec sycon 7723 1 a to 8 a 0.15 sec to 3 sec general features solid state wide operating current range. low power consumption variable current and time setting ideal for compliance to I e rule 61-a. display 3 digit led type display control features site settable current & time reset facility test mode facility input auxiliary supply 230 vac (110&415 vac optional) current sensitivity variable from 30ma to 8a settable with dip switches in three different models trip time from 0.15 seconds to 3.00 seconds settable with dip switches. Relay contacts potential free no-c-nc, 10amps at 250 vac contacts. Trip indication l.e.d cbct 65mm, 100mm, 150mm, 200mm other diameter on request.

    more..
Filter by Locality
top