10dia 18inch depth TFAL 15
Rapid sterilizer table top user friendly
Incorporated at 134” sterilizer
While drying timer is on to prevent accidental raise temperature
10dia 18inch depth TFAL 15
Rapid sterilizer table top user friendly
Incorporated at 134” sterilizer
While drying timer is on to prevent accidental raise temperature
Specifications
10dia 18inch depth TFAL 15
Rapid sterilizer table top user friendly
Incorporated at 134” sterilizer
While drying timer is on to prevent accidental raise temperature
Premium Technologies
7 minutes sterilizing time
Actual time 10-12 mins pre heating time
Temperature auto cut off system
A rack provided with 3 perforated stainless steel trays
Applications
Effective sterilization for general OT Tools
Specifications
10dia 18inch depth TFAL 15
Rapid sterilizer table top user friendly
Incorporated at 134” sterilizer
While drying timer is on to prevent accidental raise temperature
Premium Technologies
7 minutes sterilizing time
Actual time 10-12 mins pre heating time
Temperature auto cut off system
A rack provided with 3 perforated stainless steel trays
Applications
Effective sterilization for general OT Tools
Specifications
Carries IS Mark 3829 Part II.
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded.
Unique MULTIPORT VALVE located at the top. Controls all operations manually.
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up.
Works on 134°C at 32 psi (2.1 kgf/cm2).
Hydrostatically tested 2 times the working pressure.
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology.
Vacuum Pump provided along with the unit.
Premium Technologies
Instruments come out dry after the cycle.
Low water level protection for heaters.
Pressure lock device for the door.
First Cycle: 35 mins. 20 mins. Preheating time, 15 mins. Actual time. Subsequent – 09 mins.
Applications
Effective sterilization for general OT Tools
Specifications
Carries IS Mark 3829 Part II.
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded.
Unique MULTIPORT VALVE located at the top. Controls all operations manually.
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up.
Works on 134°C at 32 psi (2.1 kgf/cm2).
Hydrostatically tested 2 times the working pressure.
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology.
Vacuum Pump provided along with the unit.
Premium Technologies
Instruments come out dry after the cycle.
Low water level protection for heaters.
Pressure lock device for the door.
First Cycle: 35 mins. 20 mins. Preheating time, 15 mins. Actual time. Subsequent – 09 mins.
Applications
Effective sterilization for general OT Tools
Specifications
Inside Wall: S.S. 304.
Door: S.S. 304.
Outside Wall: Required heating arrangement for maintaining temp. in chamber will be provided. It will be properly insulated and covered.
Safety Valve provided for release of gas outside the chamber, if pressure inside chamber increases beyond 20 psi.
Temperature indicator: Range - 0 to 100°C.
Pressure Indicator: Range - 28" vacuum to 30 psi.
Vacuum System: Vacuuming is achieved using vacuum pump.
Exhaust & Air Break: Exhaust for sterilizer chamber gases is provided. For vacuum break, air suction is provided through filter.
Premium Technologies
Three trays of S.S.304 will be provided for easy loading of material.
Locking System: Manual safety lock provided on door.
Applications
Used to sterile disposables & materials with low melting point.
Specifications
Inside Wall: S.S. 304.
Door: S.S. 304.
Outside Wall: Required heating arrangement for maintaining temp. in chamber will be provided. It will be properly insulated and covered.
Safety Valve provided for release of gas outside the chamber, if pressure inside chamber increases beyond 20 psi.
Temperature indicator: Range - 0 to 100°C.
Pressure Indicator: Range - 28" vacuum to 30 psi.
Vacuum System: Vacuuming is achieved using vacuum pump.
Exhaust & Air Break: Exhaust for sterilizer chamber gases is provided. For vacuum break, air suction is provided through filter.
Premium Technologies
Three trays of S.S.304 will be provided for easy loading of material.
Locking System: Manual safety lock provided on door.
Applications
Used to sterile disposables & materials with low melting point.
An OGSI Oxygen Generator is an on-site oxygen generating machine capable of producing oxygen on demand in accordance with your requirements. In effect, it separates the oxygen (21%) from the air it is provided and returns the nitrogen (78%) to the atmosphere through a waste gas muffler. The separation process employs a technology called Pressure Swing Adsorption (PSA). At the heart of this technology is a material called Molecular Sieve (Zeolite). This sieve is an inert, ceramic-like material that is designed to adsorb nitrogen more readily than oxygen. Each of the two beds that make up the generator contains this sieve. The process is described below.
An OGSI Oxygen Generator is an on-site oxygen generating machine capable of producing oxygen on demand in accordance with your requirements. In effect, it separates the oxygen (21%) from the air it is provided and returns the nitrogen (78%) to the atmosphere through a waste gas muffler. The separation process employs a technology called Pressure Swing Adsorption (PSA). At the heart of this technology is a material called Molecular Sieve (Zeolite). This sieve is an inert, ceramic-like material that is designed to adsorb nitrogen more readily than oxygen. Each of the two beds that make up the generator contains this sieve. The process is described below.
Hospitals all over the world are realizing that on-site oxygen generation provides a highly reliable and economic solution for their oxygen requirements. Eliminate the expense of purchasing, receiving, and monitoring your hospital's oxygen supply. Costly overstock, manual handling injuries and expensive emergency cylinder deliveries all add to the expense.
It is a new source of oxygen to the entire hospital.
It does not involve any third party, for supply.
The production depends on need, results in no wastage and expiry.
Very cost effective compare to all existing sources.
Oxygen produced by this system will confirm to United States Pharmacopeia (USP) XXII oxygen 93%(+-3) monograph.
Hazardous risks of very high pressure, explosive and highly inflammability can be avoided using MOGS.
Pressure Swing Adsorption (PSA)
An OGSI Oxygen Generator is an on-site oxygen generating machine capable of producing oxygen on demand in accordance with your requirements. In effect, it separates the oxygen (21%) from the air it is provided and returns the nitrogen (78%) to the atmosphere through a waste gas muffler. The separation process employs a technology called Pressure Swing Adsorption (PSA). At the heart of this technology is a material called Molecular Sieve (Zeolite). This sieve is an inert, ceramic-like material that is designed to adsorb nitrogen more readily than oxygen. Each of the two beds that make up the generator contains this sieve. The process is described below.
MOGS provides uninterrupted O2 to your Hospital
The MOGS Plant ensures the availability of O2 on 24x7.
No manual attention required to ensure the availability of O2.
Our “Smart PP Admin” always ensures that correct purity and pressure at your outlet port‘s.
“PP Admin+” provides one push change over to high purity sources.
Hospitals all over the world are realizing that on-site oxygen generation provides a highly reliable and economic solution for their oxygen requirements. Eliminate the expense of purchasing, receiving, and monitoring your hospital's oxygen supply. Costly overstock, manual handling injuries and expensive emergency cylinder deliveries all add to the expense.
It is a new source of oxygen to the entire hospital.
It does not involve any third party, for supply.
The production depends on need, results in no wastage and expiry.
Very cost effective compare to all existing sources.
Oxygen produced by this system will confirm to United States Pharmacopeia (USP) XXII oxygen 93%(+-3) monograph.
Hazardous risks of very high pressure, explosive and highly inflammability can be avoided using MOGS.
Pressure Swing Adsorption (PSA)
An OGSI Oxygen Generator is an on-site oxygen generating machine capable of producing oxygen on demand in accordance with your requirements. In effect, it separates the oxygen (21%) from the air it is provided and returns the nitrogen (78%) to the atmosphere through a waste gas muffler. The separation process employs a technology called Pressure Swing Adsorption (PSA). At the heart of this technology is a material called Molecular Sieve (Zeolite). This sieve is an inert, ceramic-like material that is designed to adsorb nitrogen more readily than oxygen. Each of the two beds that make up the generator contains this sieve. The process is described below.
MOGS provides uninterrupted O2 to your Hospital
The MOGS Plant ensures the availability of O2 on 24x7.
No manual attention required to ensure the availability of O2.
Our “Smart PP Admin” always ensures that correct purity and pressure at your outlet port‘s.
“PP Admin+” provides one push change over to high purity sources.
Hospitals all over the world are realizing that on-site oxygen generation provides a highly reliable and economic solution for their oxygen requirements. Eliminate the expense of purchasing, receiving, and monitoring your hospital's oxygen supply. Costly overstock, manual handling injuries and expensive emergency cylinder deliveries all add to the expense.
Hospitals all over the world are realizing that on-site oxygen generation provides a highly reliable and economic solution for their oxygen requirements. Eliminate the expense of purchasing, receiving, and monitoring your hospital's oxygen supply. Costly overstock, manual handling injuries and expensive emergency cylinder deliveries all add to the expense.
Luminance : 30,000 Lux in each petal (3 petals per Dome).
Spot diameter : 150mm - 200mm.
Illumination depth : >1000mm.
Operational distance : 800mm - 1100mm.
Temperature at 1 meter level : < 1oC.
Input power supply : 220VAC at 50Hz.
Rated input power : 36W/dome.
Number of LED's per dome : 36 LED's each of 1W.
LED life : >50,000hours.
Minimum installation height : 3000mm.
CRI : 96.
Luminance : 30,000 Lux in each petal (3 petals per Dome).
Spot diameter : 150mm - 200mm.
Illumination depth : >1000mm.
Operational distance : 800mm - 1100mm.
Temperature at 1 meter level : < 1oC.
Input power supply : 220VAC at 50Hz.
Rated input power : 36W/dome.
Number of LED's per dome : 36 LED's each of 1W.
LED life : >50,000hours.
Minimum installation height : 3000mm.
CRI : 96.
Carries IS Mark 3829 Part II.
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded.
Unique MULTIPORT VALVE located at the top. Controls all operations manually.
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up.
Works on 134°C at 32 psi (2.1 kgf/cm2).
Hydrostatically tested 2 times the working pressure.
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology.
Premium Technologies
Instruments come out dry after the cycle.
Low water level protection for heaters.
Pressure lock device for the door.
First Cycle: 35 mins. 20 mins. Preheating time, 15 mins. Actual time. Subsequent – 09 mins.
Applications
Effective sterilization for general OT Tools
Carries IS Mark 3829 Part II.
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded.
Unique MULTIPORT VALVE located at the top. Controls all operations manually.
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up.
Works on 134°C at 32 psi (2.1 kgf/cm2).
Hydrostatically tested 2 times the working pressure.
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology.
Premium Technologies
Instruments come out dry after the cycle.
Low water level protection for heaters.
Pressure lock device for the door.
First Cycle: 35 mins. 20 mins. Preheating time, 15 mins. Actual time. Subsequent – 09 mins.
Applications
Effective sterilization for general OT Tools
Classic ergonomic design.
Complete pre-set Automatic Cycle with manual override (Optional : Programmable sterilization cycle with display).
Material of Construction – 100% Stainless Steel – SS304 Grade including stand, Door, Boiler, Control Panels & Fittings.
(Optional : SS316 Grade).
4 level safety feature to confirm hazard free steam environment.
Digital temperature gauge with one digit decimal value.
“Fast Fill” - Instant filling of the chamber to avoid condensation.
Industrial designed Ejector system for efficient vacuum.
Water ring cycle vacuum pump for efficient and totally dry output.
IBA certified stream trap system, to get good efficiency of the boiler.
Newly Designed Float system for upper and lower water limit of boiler.
Technical Specification
Durable and reliable industrial PLC system working with 24VDC input.
6KW * 3 -> 18KW heater element.
2.1 Bar operational pressure at 134oC temperature.
10-12 minutes rapid sterilization cycle, with energy efficient valve bench.
Safety pressure release at 3.5 Bar.
Safety temperature cutoff at 140oC.
Low water audio visual alarm.
Cycle complete, audio visual alarm.
Cycle stage indication through LED visual monitoring.
Classic ergonomic design.
Complete pre-set Automatic Cycle with manual override (Optional : Programmable sterilization cycle with display).
Material of Construction – 100% Stainless Steel – SS304 Grade including stand, Door, Boiler, Control Panels & Fittings.
(Optional : SS316 Grade).
4 level safety feature to confirm hazard free steam environment.
Digital temperature gauge with one digit decimal value.
“Fast Fill” - Instant filling of the chamber to avoid condensation.
Industrial designed Ejector system for efficient vacuum.
Water ring cycle vacuum pump for efficient and totally dry output.
IBA certified stream trap system, to get good efficiency of the boiler.
Newly Designed Float system for upper and lower water limit of boiler.
Technical Specification
Durable and reliable industrial PLC system working with 24VDC input.
6KW * 3 -> 18KW heater element.
2.1 Bar operational pressure at 134oC temperature.
10-12 minutes rapid sterilization cycle, with energy efficient valve bench.
Safety pressure release at 3.5 Bar.
Safety temperature cutoff at 140oC.
Low water audio visual alarm.
Cycle complete, audio visual alarm.
Cycle stage indication through LED visual monitoring.
Excellent LED touch pad control system : LED touch pad control system is developed for adjusment control of power switch, brightness switch, illumination level, color temperature, color rendering index, to meet medical personnel requirement of variant operation.
Cold infrared-free light : In comparison to conventional halogen and gas discharge lamps, the "cold" LED light allowing for fatigue-free operating and prevents tissue from drying out in the OT field at the head area of the surgeon
Shadow free illumination : The relation between light body and light field diameter guarantees an optimum illumination of the OT field in terms of the area and depth.
High Luminance with optimum color rendering : Designed to provide a light output with a color rendering index and color temperature which is very close to natural daylight. This helps the surgeon to distinguish between pathological and healthy tissue.
Optimum design for clean air ceilings (Laminar Air Flow) :The perfect design reduce the airflow surface beneath the ventilated ceiling, Flow- optimized light head and reduced surface temperature minimize turbulence in laminar air flow.
Long-lasting light sources, environmentally friendly :With a life cycle of at least 50, 000 operational hours, an LED provide illumination many times longer the conventional lighting. In addtion, each LED can be replaced indivdually and on site.
Excellent LED touch pad control system : LED touch pad control system is developed for adjusment control of power switch, brightness switch, illumination level, color temperature, color rendering index, to meet medical personnel requirement of variant operation.
Cold infrared-free light : In comparison to conventional halogen and gas discharge lamps, the "cold" LED light allowing for fatigue-free operating and prevents tissue from drying out in the OT field at the head area of the surgeon
Shadow free illumination : The relation between light body and light field diameter guarantees an optimum illumination of the OT field in terms of the area and depth.
High Luminance with optimum color rendering : Designed to provide a light output with a color rendering index and color temperature which is very close to natural daylight. This helps the surgeon to distinguish between pathological and healthy tissue.
Optimum design for clean air ceilings (Laminar Air Flow) :The perfect design reduce the airflow surface beneath the ventilated ceiling, Flow- optimized light head and reduced surface temperature minimize turbulence in laminar air flow.
Long-lasting light sources, environmentally friendly :With a life cycle of at least 50, 000 operational hours, an LED provide illumination many times longer the conventional lighting. In addtion, each LED can be replaced indivdually and on site.
Carries IS Mark 3829 Part II
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded
Unique MULTIPORT VALVE located at the top. Controls all operations manually
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up
Works on 134°C at 32 psi. (2.1 kgfcm2)
Hydrostatically tested 2 times the working pressure
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology
Carries IS Mark 3829 Part II
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded
Unique MULTIPORT VALVE located at the top. Controls all operations manually
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up
Works on 134°C at 32 psi. (2.1 kgfcm2)
Hydrostatically tested 2 times the working pressure
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology
Specifications
The Sterilizer capable of operating with 100% pure EO cartridge.
The sterilization temperature range will be 35°C to 60°C.
Door will be single lock system.
The system will have secondary door lock system to prevent accidental opening of door during the sterilization process.
Unit with Stainless Steel cage with two trays.
Premium Technologies
Automatic Microprocessor Controlled ETO Sterilizer.
LCD display for Cycle Progress (i.e. Temperature, Vacuum Pressure, Cycle Phase, Set Values, Current Values with Contents of Time).
The puncturing of 100% EO cartridge automatic after success of a leak test status.
This system has built in water spray system for Humidification.
It will be a stand alone unit. Chamber, Door made of stainless steel 316.
Applications
Both automatic and manual operating machine’s are available
Available sizes :
12" X 12" X 24"
12" X 12" X 48"
12" X 12" X 54"
12" X 12" X 60"
16" X 16" X 36"
Specifications
The Sterilizer capable of operating with 100% pure EO cartridge.
The sterilization temperature range will be 35°C to 60°C.
Door will be single lock system.
The system will have secondary door lock system to prevent accidental opening of door during the sterilization process.
Unit with Stainless Steel cage with two trays.
Premium Technologies
Automatic Microprocessor Controlled ETO Sterilizer.
LCD display for Cycle Progress (i.e. Temperature, Vacuum Pressure, Cycle Phase, Set Values, Current Values with Contents of Time).
The puncturing of 100% EO cartridge automatic after success of a leak test status.
This system has built in water spray system for Humidification.
It will be a stand alone unit. Chamber, Door made of stainless steel 316.
Applications
Both automatic and manual operating machine’s are available
Available sizes :
12" X 12" X 24"
12" X 12" X 48"
12" X 12" X 54"
12" X 12" X 60"
16" X 16" X 36"
Specifications
Carries IS Mark 3829 Part II
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded
Unique MULTIPORT VALVE located at the top. Controls all operations manually
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up
Works on 134°C at 32 psi. (2.1 kgf/cm2)
Hydrostatically tested 2 times the working pressure
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology
Vacum Pump provided along with the unit
Power: 18 kW, 440 V, 3-phase
Premium Technologies
Locking System: Manual safety lock provided on door.
Low water level protection for heaters
Pressure lock device for the door
Instruments come out dry after the cycle
Applications
Steam: Effective sterilization for general OT Tools
ETO: Used to sterile disposables & materials with low melting point.
Specifications
Carries IS Mark 3829 Part II
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc welded
Unique MULTIPORT VALVE located at the top. Controls all operations manually
Two safety valves (dead wt. & spring loaded) and a pressure switch provided to prevent accidental pressure build up
Works on 134°C at 32 psi. (2.1 kgf/cm2)
Hydrostatically tested 2 times the working pressure
Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro and Urology
Vacum Pump provided along with the unit
Power: 18 kW, 440 V, 3-phase
Premium Technologies
Locking System: Manual safety lock provided on door.
Low water level protection for heaters
Pressure lock device for the door
Instruments come out dry after the cycle
Applications
Steam: Effective sterilization for general OT Tools
ETO: Used to sterile disposables & materials with low melting point.
Truly "MAKE IN INDIA"
Provides ease of operation through complete electro-pneumatic control systems.
Dual source selectable switch for bellow driving gas.
Dual Selectatec bar with interlocking.
Compact and “Easy fill” CO2 absorber.
Standard Mode: IPPV (Desired Volume by Pressure Regulation).
Five tube rotameter with Gear Engaged Ratio Controller (GERC).
Secondary safety: O2 piloted N2O cutoff valve.
Alarms: Electronic O2 Failure alarm with mute option, Airway pressure high and low alarm.
Tidal volume from 50ml to 300ml with pediatric bellow and 300ml to 1500ml with adult bellow.
Enhanced long duration power backup up to 120 minutes.
360o rolling wheels with front stamp locking.
Spacious trolley designed ergonomically.
Suitable for pediatrics and adults
Clear LED 7 segment display separately for Tidal volume, Airway pressure, Rate and I: E ratio.
Truly "MAKE IN INDIA"
Provides ease of operation through complete electro-pneumatic control systems.
Dual source selectable switch for bellow driving gas.
Dual Selectatec bar with interlocking.
Compact and “Easy fill” CO2 absorber.
Standard Mode: IPPV (Desired Volume by Pressure Regulation).
Five tube rotameter with Gear Engaged Ratio Controller (GERC).
Secondary safety: O2 piloted N2O cutoff valve.
Alarms: Electronic O2 Failure alarm with mute option, Airway pressure high and low alarm.
Tidal volume from 50ml to 300ml with pediatric bellow and 300ml to 1500ml with adult bellow.
Enhanced long duration power backup up to 120 minutes.
360o rolling wheels with front stamp locking.
Spacious trolley designed ergonomically.
Suitable for pediatrics and adults
Clear LED 7 segment display separately for Tidal volume, Airway pressure, Rate and I: E ratio.
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Cistron Systems established in 1993 has been serving it customers with Sales and Service of Technology Medical Products for more than 20 years. We are proud to have over 8500 satisfied customers in the Medical Industry . We thank all our customers for their patronage to Cistron and hope to have their continued support in the years to come. Cistron believes in technology and in the past 23 years, has introduced, modified and upgraded many products starting from Operation Room equipment to Critical Care to Diagnostics and so on. It is always our endeavour to ensure our customers have the best technology products, at the most affordable prices, backed with very efficient and prompt after Sales Services. At Cistron, we believe and feel satisfied only when our customers reap the benefits of the product they have purchased , for which we have a very well trained Customer support team. Cistron employees and specifically Service Engineers are well qualified and trained for the job. We undertake continuous training program for them to ensure they stay updated to serve our customers. In continuation of our dreams to introduce technology products , we are launching the most trusted PSA Technology Oxygen generating plants which will revolutionize the Medical Oxygen industry. The MEDICAL OXYGEN GENERATING SYSTEMS ( MOGS ) will provide oxygen on demand , without interruption and hassles. Your one time investment in this product will ensure long time savings.