Gas Analyzers Dealers in Vadodara

(31 products available)
  • Premium
    Toxic Gas Analyser +3

    Toxic Gas Analyser

    50,000 - 200,000 / Piece

    • Number Of FlowerGas Analyser
    • Power Supply230 V AC, 50Hz, Single Phase, 5 Amps, Stabilized
    • Display16 X 2 LCD With Back Light
    • Working Temperature0-50°C
    • Size & Weight225 X 200 X 120 Mm Deep & 1.5 Kg
    • Flow Indicator0 - 2 LPM Provided
    • Response Time3 To 15 Sec < T90 At 20
    • Introduction: GAS ANALYSERS TGA-1 accurately measures the concentration of a Oxygen gas in parts per million (ppm)/parts per billion (ppb)/%. These gas analyzers use electrochemical/NDIR/ PID/Pallister sensors which have an enviable reputation for reliability, stability, and rugged design having an output linearly proportional to the concentration level of the gas.Application:Gas Analysers TGA-1 find application in - Process Control, Quality Control, Area Surveillance Safety in work areas of Factories and Research institutionsFeatures:  One alarm audible & visual. User can Set Alarm with a setpoint view. Alarm relay SPDT with NO, C, and NC for online models. 4-20 mA & RS485 MODBUS for On-line models. Power 180~230 VAC OR Rechargeable battery option available (to be specified in the order). Portable models are offered with the INBUILT PUMP & FLOW INDICATOR option to draw sample gas. Easy accessible Key Function: Escape, Enter, Up, Down. OPTIONS for PORTABLE instruments only Internal pump with suction of 4”Hg Column and flow of 2 LPM Rechargeable 12 V battery with charger & Low Battery Alarm. Accessories: Carrying Case, battery charger, 1-meter tube. OPTIONS for ON LINE instruments only Panel Mount Enclosure. Accessories: Carrying Case, Panel Mounting clamps, 1-meter tube. OPTIONS for Sensor mounting Either internal with an internal pump OR surface mounting as diffusion on the instrument. Externally on the end of a cable in diffusion mode only Technical Specifications:Display              : Display 16 x 2 LCD with Back LightWorking temp    : 0-50°CAccuracy           : + 1% FS at constant temperatureSize & Weight    : 225 x 200 x 120 mm deep & 1.5 KgTechnology        : Electrochemical/NDIR/PID/PallisterData                 : USB Output (Optional)Downloading     : 4-20 mA Recorder OutputRecorder O/P     : RS485 MODBUS RTUDrift                 : ± 1% FS as per 6 monthsEnclosure          : Table Top ABSData Storage     : In-built 100 readings (in auto sample mode)Power Supply     : 230 V AC, 50Hz, Single phase, 5 Amps, Stabilized. Optional: rechargeable                                      battery Alarm               : Visual & audible, settable thro’ range. Low battery alarm also with Relay (SPDT)                              OutputFlow Indicator   : 0 – 2 LPM provided.Response Time  : 3 to 15 Sec < T90 at 20~80%RH
    ...more
    www
  • Head Space TOGA Analyzer

    Head Space TOGA Analyzer

    Get Price Quote

    The Touch Screen GC System Model Dhruva  S2TS (NTPC & ERDA Approved) is configured For Dissolved Gas Analysis of transformer oil. It Can Be Built To  Meet The Specification / Standards As Per ASTM D 3612  Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user. This equipment can be used to detect the incipient fault in the transformer  and  arrest deterioration/damage to the transformer insulation by analyzing gases dissolved in the transformer oil and adopt preventive measures. Gas Chromatography method is used for detection for the dissolved gases and identification of incipient faults. The most significant gases generated by decomposition of oil deterioration, of paper insulation on the conductor are hydrogen, methane, ethane, ethylene,  acetylene, CO , Carbon di-oxide, Oxygen & Nitrogen. The quantities of these gases dissolved in transformer oil vary depending upon the type and severity of fault condition such as arcing, partial discharge, overheating, low-high temperature hot spot etc. The process involved is separation, identification and quantitative determination of gases.The Dhruva S2TS analyzes the fault gases in a single injection with gases analysed depending upon user ordering.   Innovative & Advanced Features : Color Touch Screen control with optional control over TCP-IP using FTP protocol Meets  ASTM D 3612  Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user. 10 or 40  Vial Head Space Auto Sampler (Choice of Manual Head Space Sampling as per Section C / 7.5) . Auto tuning PID temperature control for up to 8 channels with 2 programmable zones & 6 isothermal zones. EPC for up to 8 channels with 2 programmable zones & 6 single set point control with 0.25% FSD accuracy. Up to 12 auxiliary device control with 4 step programming for control of GSV, Solenoids, Pumps, trigger, signals etc. Input status for Pressure, Remote start, Remote Stop, Door open along with 4 additional spare inputs. Programmable FID (Gain, Off Set, and Sensitivity – low, high) with time based sensitivity settings. Programmable TCD (Sensitivity – Low, Medium, High) with superb current stability & repeatability. Extensive Auto diagnostics & user friendly system control with User settable password protection. Multi mode screens with 6 pages of current status giving complete GC status with option for continuous looping of the system.
    ...more
  • Oxygen Gas Analyzer

    Oxygen Gas Analyzer

    19,911 / Piece

    • BrandKusam-Meco
    • Power Supply3x1.5VAAA alkaline batteries
    • Measuring Range0 25% (Vol)
    • Dimension172 x 51 x 26 mm
    • Model NoKM 5490
    • Measurement DisplayDisplays 4 digit LCD
    • Resolution0.1% (Vol)
    • Measurement Error0.5%
    • Storing Humidity20%
    ...more
  • Oxygen Gas Analyzers

    Oxygen Gas Analyzers

    Get Price Quote

    • PrincipleGalvanic Cell
    • DisplayDigital
    • Ranges0–199.9PPM
  • Head Space Oxygen Analyzer +1

    Head Space Oxygen Analyzer

    43,500 - 45,500 / piece

    • MOQ1 piece
    • Display TypeDigital
    • Usage/ApplicationIndustrial Use
    • BrandPRIMA
    • Country of OriginIndia
    • Size &amp; Weight195 x 98 x 155 mm depth, 1.5 Kgs approx.
    • The PRIMA Head Space Oxygen Meter-HSOM has a specially designed sampling configuration with an inbuilt pump and timer switch and an ultrasensitive oxygen sensor that makes it feasible to accurately measure oxygen contamination in the headspace flexible food packs or tin cans. The Model incorporates an adapted hypodermic needle to pierce the loose food packs and draw the gas using the inbuilt pump. In the case of headspace analysis of tin cans, Model HSOM when used with the tin can piercer device provides the headspace analysis of % oxygen in the tin can of heights up to 380 mm. The high vacuum pump is designed to educts the headspace atmosphere of low internal pressure. Models can work on 220 VAC mains supply or on Rechargeable Battery. This portable instrument is available with a digital readout 0-25% 02 range and 0.1 % oxygen in steps with front adjustments for zero, calibration & sampling of the headspace gas. Applications : The food packaging industry uses modified atmospheres to improve shelf life and quality of nuts, wafers, snack foods, oils, skimmed milk, milk powder and many other packaged food products within various food packages such as soft packs pouches, tin cans or bottles. Model HSOM provides an analysis method for headspace oxygen that helps quality control by determining the residual oxygen in the headspace. Model HSOM helps to adjust the speed of nitrogen gas while packaging correctly. The simplicity of operation of Model HSOM makes it ideal for quick routine measurements and repetitious laboratory studies. Technical Specifications: Display                :  3 and ½ Digit LCD 12 mm high Range                 : 0 - 0.25% Resolution           : 0.1% Accuracy             : +2% at constant temperature Power                 : Rechargeable batteries/ 230VAC Mains Supply Sensor type        : Electrochemical Sensor life          : Two years of expected life Working temp.    : 5-45°C Recorder Output  : 0-1 V (Battery operated models) Size                    : 195 x 98 x 155 mm depth Weight                : 1.5 kg approximately Calibration          : By ambient air or certified calibration gas In-built Pump Version: Gas Eduction      : By internal pump Pump Suction     : Minimum 8" Hg Column Flow                  : 0.5 Liter/Minute Pump Timer       : Adjustable between 3 to 30 Seconds (optional) Features: Internal Pump to draw a sample. Easy to operate. Adjustable timer for sample pump. Portable, lightweight Ultrasensitive Oxygen Sensor Tin can pierce press & stand available with hardened needles. Accessories: Carrying case For Inst., Charger & Accessories, Panel mounting clamps For Inst., Charger & Accessories Hypodermic syringe Three nos. Needles and one lock valve. Self-Adhesive pads 500 Nos. cut pieces of foam for flexible packs Battery charger For Rechargeable Battery operated models, only 
    ...more
  • Oxygen Analyzer/Online Gas Analyzer

    Oxygen Analyzer/Online Gas Analyzer

    Get Price Quote

    Based on our own proprietary Diode Laser Absorption Spectroscopy (DLAS)technology, LGA-2000 Laser Gas Analyzer is capable of continuous on-the-spot gas concentration measurement and monitoring. It Demonstrates the characteristics of in situ detection in lieu of sampling, high measurement precision, short Response time, easy installation and maintenance, and etc. Application fields: Metallurgy, Petrochemical industry, biochemical pharmaceutics, environmental protection and Waste management, aeronautics and astronautics and other situations where gas analysis are needed  
    ...more
  • Chlorine Gas Analyzer

    Chlorine Gas Analyzer

    89,000 - 90,000 / Piece

    • Brand NameOptima
    • Usage/ApplicationLaboratory
    • Automation GradeAutomatic
    • Packaging TypeBox
  • Dissolved Oxygen Analyzer

    Dissolved Oxygen Analyzer

    125,000 - 300,000 / Piece

    • Number Of FlowerOxygen sensor
    • ApplicationFlue Gas Analysis
    • Availability0-5kg
    • FeatureAccuracy
    • ConditionNew
    • Driven TypeBattery, Electric
    • Detected gasO2
    • Automation GradeAutomatic
    • Voltge3-6VDC
    • Country of OriginIndia
    • Oxygen Analyzers 
  • Oxygen Analyser

    Oxygen Analyser

    Get Price Quote

    • Sr. NoDescriptions
    • Details1.
    • MakeNucon Engineers
    • 2.Range
    • 0-30%3.
    • DisplayDigital
    • 4.Resolution
    • 0.1%5.
    • SensorGalvanic type made by citicell-USA
    • 6.Power
    • 230 V AC7.
    • Alarm230 V AC, NO/NC
    • 8.Recorder Output
    • To monitor oxygen level in Nitrogen Gas Generator we required to install an Oxygen Gas Analyzer. This Analyser will be digital type mounted in Control Panel. In case of high O2%, it will give signal on panel and in turn impure gas shall be vented to atmosphere through vent valve provided in our system. Applications : Gas Purity Check Combustion Efficiency Studies Giove Boxes Cryogenics Microbiology Metallurgy Chemical Engineering Plastic Manufacturing Food and Beverage Packing Bio Technology Electronics Flue Gas Analysis
    ...more
  • Oxygen Gas Analyzer

    Oxygen Gas Analyzer

    Get Price Quote

    andy Oxygen Gas Analyzer : The Handy Oxygen Gas Analyzer are designed for accurate and reliable measurement of Oxygen in Air, Nitrogen, Argon, Hydrogen etc. Our Oxygen Gas Analyzer are based on state of art Galvanic Oxygen Sensors, and provide fast response. Our Oxygen Gas Analyzer require no periodic maintenance like replacing electrodes or electrolyte and can be calibrated using ambient air or standard calibration samples. A digital display provides direct percentage output readout. The power Source is a 9V battery. Use of C MOS integrated Circuits ensures low power consumption for long battery life. Model 101 is an Oxygen Monitor for general applications. Model 102 additionally has low Oxygen set alarm facility which is usually preset to 19.0 % intended for personal safety usage and warns if Oxygen level falls below acceptable to human system.   Specifications : Range : 0.0% - 25.0% with least count 0.1%.  Accuracy : + 2% full scale.  Response Time : 90 % in less than 15 Sec.  Display : LCD.  Sensor Type : Galvanic Power Source : One 9V battery.  Alarm System : Audio / Visual.  Weight : 400 Gms. approx. Special Feautres : Pocket Size .  Light Weight .  Easy to read Display.  Low Battery Indicator.  Audible / Visual Alarm. Accutate Disposable Galvanic Sensor.   Application :Gas Purity Check. Combuction Efficiency. Glove Boxes.Cryogenics . Microbiology  Metullargy.Chemical Engineering. Plastic Manufacturing.  Food and Beverages Packing.  Bio-Technology. Personal Sagety. Mines. Medical Respiratory Studies. Anaesthetic Monitoring. Baby Incubators..
    ...more
  • PressData Medical Gas Alarm Analyser +4

    PressData Medical Gas Alarm Analyser

    45,000 - 59,000 / piece

    • MOQ1 Piece
    • Brand NamePressData
    • Driven TypeBattery
    • ConditionNew
    • Automation GradeAutomatic
    • ApplicationMedical Use
    • CertificationISO 13485
    • Number Of FlowerMedical Gas System
    • Total Carbohydrate2Yrs
    • Country of OriginIndia
    • PressData - Medical Gas Alarm + Analyzer system for Medical Gas Pipeline, Hospital Gas Supply, OT, ICU, etc..PressData Features :5 Positive pressure ( Oxygen-2, Air, Co2, N2O) and Vacuum = total 6 ChannelsCompact, Light Weight, Sleek unitWall mountable as well as Table-top unitStandard input gas connectionsBuilt-in battery, charger and switch over circuitBig Touch screen LCD display control panelAll six pressures real time continuous displayAll six pressures High + Low Alarm setting – user adjustable – Audio and Video alarmsReal Date-Time display with Room Temperature and Humidity measurementWi-Fi Enabled Control panel for Mobile connectivity for wireless monitoring + Control + Data storage + Data Analysis + Report GenerationFree App PressData from Google Play StoreCan be integrated with InOT Surgeons OT Control Panel
    ...more
  • Power Quality Analyzer

    Power Quality Analyzer

    Get Price Quote

    • ProductORACLE
    • the new oracle incorporates newly enhanced features including a faster arm processor to support continually evolving capabilities, a complete 8 mb  of nonvolatile internal memory and auxiliary power input capabilities. power quality data  can be downloaded from the instrument to pc or laptop.  the oracle records power quality and power flow information simultaneously. the recorded information can be viewed via the built-in graphics display & downloaded to a computer using the usb interface. trinity offers a comprehensive line of flexible voltage probes and clamp-on current probes for use with oracle.
    ...more
  • Automatic Moisture Analyzer

    Automatic Moisture Analyzer

    232,000 / Unit

    • MOQ1 Unit
    • Display TypeDigital
    • Accuracy0.01 %/0.001 g
    • Total Carbohydrate1 Year
    • Automatic GradeAutomatic
    • Brand NameOhaus
    • Data Memory Function Type100 data Readings for 100 Method
    • Heating TechnologyHalogen
    • Weight5.23 kg
    • Internal Data StorageYes
    • I Deal InNew Only
    • Output TypeRS232, USB host, USB device
    • Readability0.01 %/0.001 g
    • Power120 or 240 VAC 50/60 Hz
    • Maximum Capacity120g
    • Pan Size90 mm
    • Size/Dimension210 x 180 x 350 mm
    • Temperature Range40-230 DegreeC
    • Resolution0.05 % (3 g sample) 0.015 % (10 g sample)
    ...more
  • Blood Gas Analyzer:

    Blood Gas Analyzer:

    Get Price Quote

    BG 2100 is an innovative ISE Electrolyte and Blood GasAna|yzercomplementlng our existing ISE NG.The analyzer measures K+, Na+, Cl+, Ca++, pH, PCO2 and PO2 in whole blood, serum and plasma. The analyzer has a compact design, is easy to operate, economical and is virtually maintenance free. The aspirate probe has a self-cleansing mechanism affording enhanced operator safety, low carry-over and cross-contamination . 240 *128 dots LCD Display ' Soft, Keypad -200 pL Sample Volume -Whole Blood, Serum, Plasma - 65 Samples / hour Throughput Built-in Thermal Printer
    ...more
  • Oxygen Analyser

    Oxygen Analyser

    24,000 / Piece

    • MOQ1 piece
    • CertificationCE Certified
    • Availability0-5kg
    • FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Low Battery Consumption, Mercury-free
    • ConditionNew
    • Driven TypeBattery, Electric
    • Detected gasO2
    • Voltge9-12VDC
    • Country of OriginIndia
    • Brand NameInmed
    • Accuracy+/-1%
    • Portable ,compact and light weight Easy user operation Sensor disconnect failure alarm Auto diagnostics with fault messages Measurement angel O - 1OO % Battery as well as mains operated Microprocesor controlled for enhanced performance Large easily read back-lit LCD display Audible and visual alarms with different sounds Simple system with auto one touch calibration Fast sensor response & long life Measurement range: I 18-1OO % oxygen Powers upply:I 9V rechargeable battery Averaging time : user selectable 0,- 9 Sec Normal sensor life : moret han1 0,00,000 Vol% h Expected operating life: less than5 years@ ambient air
    ...more
  • Oxygen Analyzer

    Oxygen Analyzer

    Get Price Quote

    • Automation GradeAutomatic
    • Voltage230V
    • Normal operating temperature0-55°C
    • Warm up time30 minutes
  • CHNS+O COMBO ANALYSER

    CHNS+O COMBO ANALYSER

    5,300,000 / piece

    • MOQ1 Piece
    • BrandAnalytical Technologies Limited
    • Country of OriginIndia
    • SensitivityOxygen ,Nitrogen, Hydrogen, Carbon and Sulfur :0.01ppm
    • RepeatabilityOxygen, Nitrogen and Carbon : 1ppm or 1%; Hydrogen : 0.2ppm or 2% Sulfur : 1.5%
    • Sample mass1g (Sample mass can be changed according to the content)
    • Analysis timeabout 3 min
    • Carrier gasHigh purity helium for O/N, high purity nitrogen for H Oxygen: purity >99.5%, pressure 0.30 MPa, pressure of furnace end 0.05MPa, 3L/min
    • Pneumatic gasNitrogen or compressed air Pressure imported 0.30 MPa
    • StructureModular Structure, including analyzer, computer, electronic balance*, printer*, water circulate chillers
    • Chemical reagentMagnesium perchlorate, Ascarite
    • Electronic balanceWeighing range: 0g-120g. Precision of read: 0.0001g.
    • Instrument Principal :  CHNS+O Analyzer is a new product, and it is used for oxygen,nitrogen, hydrogen, Carbon, Sulfur determination in ferrous and non-ferrous metals, rare earth materials, alloy, semiconductors, electronic materials, ores, ceramics, coal, graphite, and some organic / inorganic materials. Pulse heating inert gas fusion. O (Oxygen): NDIR(Non Dispersive Infrared absorption); N/H (Nitrogen/Hydrogen): TCD(Thermal Conductivity Detection) Carrier gas (Oxygen) pass through sample extraction unit. Sample combustion at a high temperature, the carbon and sulfur in the sample were converted to CO2 and SO2.and then the mixed gas was measured by infrared detector. The infrared detector using Non-Dispersive-Infrared absorption technology, and it can quickly and accurately measuring carbon & sulfur contents, and it is easy to operate, easy to maintain, easy to repair. Instrument Specification :  1. Structure : Modular Structure, including electronic balance, computer, printer, high-frequency infrared carbon & sulfur analyzer, tubular resistance furnace, vacuum cleaners, water circulate chillers. 2. Detection System : (i) Solid state Infrared detector is used for Oxygen. Thermo-conductivity detector is used for Nitrogen & Hydrogen. (ii) IR Cell: Standard configuration of measure scope is composed of low carbon, high carbon and low sulfur. For specially required scope for sulfur, high sulfur can be added. (iii) Detector: Solid-state pyroelectric detector. (iv) Motor: Synchronous motor made in Swiss, continuously working. (v) IR Emitter: Anti-oxide, stable IR emitter. (vi) Temperature control: Keep constant temperature in the whole infrared unit to make sure the temperature of detected gas to be stable and the results to be accurate. (vii) Protective gas: Controlled gas flow to purify and protect IR emitters and detectors, avoiding the influence of ambient to improve the stability and accuracy. (viii) Thermo-conductivity (TCD) detecting unit: Anti-oxide NTC thermistor (ix) Signal processing: Small current control technique is developed to make sure the thermistors can be used without carrier gas (x) Reference gas circuit: Low flow control technique is used.    3. Gas flow control: High sensitive and accurate electric flow control technique based on the low pressure difference is applied, and Anti-Overshoot System is applied. 4. Catalyst unit : a) Catalyst heater: Convert CO to CO2 and SO2 to SO3. b) Filter: SO3 is removed by a filter, to ensure the tail gas reach the requirement of atmospheric environment protection. 5. Dust filter : Made of powdered metal technique, can be reused by washing in ultrasonic cleaner periodically. Cleaning filter and combustion chamber twice during one analysis by special design of the furnace, which reduce the difficulty of daily maintenance. 6. Weighing: Sample mass can be transfer from balance into computer automatically, If necessary, the mass can also be manual input. 7. Analysis time : A typical analysis using induction furnace requires 30-40 seconds. 8. Crucible Ceramic crucible using in induction furnace is 25mm in diameter. 9. Furnace: High frequency induction furnace, 18MHz, Max 2.7KVA, (Temperature: Max.3000o C) 10. Calibration: 1) Fast calibration 2) Normal calibration 11. Power: 220VAC 10%, 50/60Hz, current max. 50A.  
    ...more
  • Moisture Analyzer

    Moisture Analyzer

    Get Price Quote

    We offer reliable moisture analyzers with a combination of features to suit individual needs and budget. In addition, our analyzing insturment offers superior sensitivity,speed of response, and calibration stability. Moisture analyzers of bts series are used for quick and precise determination of material humidity upon the basis of weight loss during drying of its small sample (thermo-gravimetrical method
    ...more
  • Oxygen Concentrator Analyzer OxyData-C b

    Oxygen Concentrator Analyzer OxyData-C b

    39,000 / Unit

    • MOQ1 Unit
    • Country of OriginMade in India
    • Automation GradeAutomatic
    • Model Name/NumberOxyData
    • PowerPortable Hand-Held
    • I Deal InNew Only
    • Brand NameOxyData
    ...more
  • Flue Gas Analyzer

    Flue Gas Analyzer

    Get Price Quote

    • Featurepressure measurement, heating system check
  • Advance Optima Gas Analyzer

    Advance Optima Gas Analyzer

    Get Price Quote

    • FeatureOptimum performance, Superior functionality, Minimum maintenance
  • Portable Flue Gas Analyzer

    Portable Flue Gas Analyzer

    Get Price Quote

    • FeatureRechargeable Battery Pack , Protective Carrying Case, , Efficiency
  • Gas Analyzer

    Gas Analyzer

    Get Price Quote

    Gas Analyze
  • Fuel Gas Analyzer

    Fuel Gas Analyzer

    Get Price Quote

    Fuel Gas Analyzer, Capacitor Panels, Co Gas Detector, Control Panel
  • Gas Analyzer

    Gas Analyzer

    Get Price Quote

    Gas Analyzer, Safety Shoes, COD Digester, Monitoring System, Digital Mete
  • Gas Analyser

    Gas Analyser

    Get Price Quote

    Gas Analyser, Electromagnetic Flow Meters, Coriolis Mass Flow Meter
  • Ammonia Analyzers

    Ammonia Analyzers

    Get Price Quote

    Ammonia Analyzers, CHCOD-810 portable COD analyzer, Phosphate Analyze
  • Gas Analyzers

    Gas Analyzers

    Get Price Quote

    Gas Analyzers, Ammonia Cracking Gas Units, Industrial Gas Generator
  • Tail Gas Analyzer

    Tail Gas Analyzer

    Get Price Quote

    Tail Gas Analyzer, Spectrophotometer, Sulphur Analyzer, Digital Gas Mixe
  • Combustion Nitrogen Gas Analyzer

    Combustion Nitrogen Gas Analyzer

    Get Price Quote

    Combustion Nitrogen Gas Analyzer, Actuator for Air Dampe
Filter by Locality
top