Number Of FlowerHuman Body Static Dissipator - LAMP Model
ModelVITALHBSD
Max Test voltage1.5 V DC
Power Supply230 V AC FLP
Vital Human Body Static Dissipator wit LAMP IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.
Vital Human Body Static Dissipator wit LAMP IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.
Brand Name : VITAL,Vital
Material : CAST IRO LM
Application : Human Body Earthing
Number Of Flower : Human Body Static Dissipator - LAMP Model
Number Of FlowerHuman Body Voltage Checker, Human Body Static Discharge
Country of OriginIndia
Model NumberVITALHBSD
Vital Human Body Static Dissipater.To discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Vital Human Body Static Dissipater.To discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Brand Name : VITAL
Material : Aluminium
Application : Human Body Static Earthing
Certification : CE Certified
Number Of Flower : Human Body Voltage Checker, Human Body Static Discharge
The loading and unloading of tank trucks, containers, mixers etc containing flammable or combustible products has long been recognized as one of the most serious fire and explosion risks for hazardous industry operations.
A study conducted by the American Petroleum Institute in 1967, for example, identified static discharges as being responsible for more than 60 incidents in tank truck loading operations, Mixing Operations, Drum Filling etc..
Since then more stringent preventive standards have been developed and significant advancements have been made in the technology of static electric discharge prevention. Yet accidents traced to static electric discharges still occur, with sometimes tragic results.
The natural presence of static electricity during product transfer operations, combined with its associated ignition hazards, ensure that regulators take static control precautions for tank trucks very seriously. The primary guidelines are detailed in three primary standards: NFPA 77, API RP 2003 and
Certified as Per:
Certifications - CIMFR / PESO (Optional) IP 66, Gas Group IIA IIB IIC(Optional)
The loading and unloading of tank trucks, containers, mixers etc containing flammable or combustible products has long been recognized as one of the most serious fire and explosion risks for hazardous industry operations.
A study conducted by the American Petroleum Institute in 1967, for example, identified static discharges as being responsible for more than 60 incidents in tank truck loading operations, Mixing Operations, Drum Filling etc..
Since then more stringent preventive standards have been developed and significant advancements have been made in the technology of static electric discharge prevention. Yet accidents traced to static electric discharges still occur, with sometimes tragic results.
The natural presence of static electricity during product transfer operations, combined with its associated ignition hazards, ensure that regulators take static control precautions for tank trucks very seriously. The primary guidelines are detailed in three primary standards: NFPA 77, API RP 2003 and
Certified as Per:
Certifications - CIMFR / PESO (Optional) IP 66, Gas Group IIA IIB IIC(Optional)
Static Discharge Touch Pad With LED IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.\\nCold Resistance: 20 +/- 30 C\\nCountry of Origin: Made in India\\nBrand: Vital\\nUsage/Application: Human Body Static Discharge\\nModel Name/Number: VITTP01-SS\\nType: Static Discharge Touch Pad\\nMaterial: SS304\\n \\nPAD Size: 30 x 30 cm
...more
SS304 Static Discharge Touch Pad with LED Indication
Static Discharge Touch Pad With LED IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.\\nCold Resistance: 20 +/- 30 C\\nCountry of Origin: Made in India\\nBrand: Vital\\nUsage/Application: Human Body Static Discharge\\nModel Name/Number: VITTP01-SS\\nType: Static Discharge Touch Pad\\nMaterial: SS304\\n \\nPAD Size: 30 x 30 cm
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
Brand Name : VITAL,VITAL
Material : Cast iron LM6 Alluminium
Application : Earth Monitoring of Plant Equipments
ECVI is speciality clamp Intrinsically safe with visual indication on the clamp itself. (SS304 Earth Clamp Body)
It shows Green and Red indication in case of healthy and unhealthy earth connection respectively. The clamps are made of Pure SS304 Clamps with quality spring pressure and with 20.00 mm Jaw opening diameter to earth hazardous operations. The tips are made of tungsten carbide to penetrate through dust, coating, paint etc. and make a positive connection with the object.
Application : To Earth Mobile Equipments, Drums, Tankers, Reactors, FDB, Sifters, Hoppers etc..
Certified as Per:
IS/IEC 60079-0:2007IS/IEC 60079-11:2006IS/IEC 60529:2001
Marking on Equipment -Ex ib IIb Gb T4 ( 0to < Ta < +50)
ECVI is speciality clamp Intrinsically safe with visual indication on the clamp itself. (SS304 Earth Clamp Body)
It shows Green and Red indication in case of healthy and unhealthy earth connection respectively. The clamps are made of Pure SS304 Clamps with quality spring pressure and with 20.00 mm Jaw opening diameter to earth hazardous operations. The tips are made of tungsten carbide to penetrate through dust, coating, paint etc. and make a positive connection with the object.
Application : To Earth Mobile Equipments, Drums, Tankers, Reactors, FDB, Sifters, Hoppers etc..
Certified as Per:
IS/IEC 60079-0:2007IS/IEC 60079-11:2006IS/IEC 60529:2001
Marking on Equipment -Ex ib IIb Gb T4 ( 0to < Ta < +50)
FLP/WP Advanced Continuous Earthing Monitoring System with HooterWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.
...more
Continuous Earth Monitoring System with Resistance Display and Hooter
FLP/WP Advanced Continuous Earthing Monitoring System with HooterWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.
ApplicationHuman Body Static Discharge & Grounding
Number Of FlowerStatic Charge Eliminator
Country of OriginIndia
Country of Origin220v
Human Body Static Dissipator
To discharge the static charge developed in human body to the ground, human body static dissipator provides
complete solution, by measuring the resistance of human body and providing conductive path for static charge
dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of
spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending
on the measured value of resistance. It also provides path for static charge of the human body to discharge to
earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human
body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the
device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output
contact is available which can be used for annunciation or interlock with the access door or gate to restrict
entry of people only after static charge dissipation.
Technical specification
Power supply - FLP 230 V AC
Type of Ex protection Ex”d”
Temperature Class T4/T6
Interlock contact YES – 02 NO/NC
Display Resistance Display
LAMP Green – Healthy Discharge
Red – OPEN or Not Discharged
Present resistance value 750K-1 M ohm
Mounting Wall mounting
Handles Test & Ref. Ground handle/Plate – SS304
Power On/Off switch 06 Amp
General Flame Proof Enclosure Specifications
Flame proof (Explosion proof) Ex-d
Area Classification Zone 1 & 2
Gas Groups IIA IB IIC(Optional)
Material Touch handles SS304, SS316(Optional)
Temperature Class T6 (85 deg.C)
Human Body Static Dissipator
To discharge the static charge developed in human body to the ground, human body static dissipator provides
complete solution, by measuring the resistance of human body and providing conductive path for static charge
dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of
spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending
on the measured value of resistance. It also provides path for static charge of the human body to discharge to
earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human
body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the
device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output
contact is available which can be used for annunciation or interlock with the access door or gate to restrict
entry of people only after static charge dissipation.
Technical specification
Power supply - FLP 230 V AC
Type of Ex protection Ex”d”
Temperature Class T4/T6
Interlock contact YES – 02 NO/NC
Display Resistance Display
LAMP Green – Healthy Discharge
Red – OPEN or Not Discharged
Present resistance value 750K-1 M ohm
Mounting Wall mounting
Handles Test & Ref. Ground handle/Plate – SS304
Power On/Off switch 06 Amp
General Flame Proof Enclosure Specifications
Flame proof (Explosion proof) Ex-d
Area Classification Zone 1 & 2
Gas Groups IIA IB IIC(Optional)
Material Touch handles SS304, SS316(Optional)
Temperature Class T6 (85 deg.C)
Brand Name : VITAL
Material : Aluminium
Condition : New
Application : Human Body Static Discharge & Grounding
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC CIMFR / PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC CIMFR / PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
FeatureAccuracy, Durable, Easy To Operated, Long Life, Quality Tested
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC(Optional), CIMFR or PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC(Optional), CIMFR or PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
Brand Name : VITAL ENGINEERING INSTRUMENTS
Material : Aluminium
Driven Type : Power Supply
Condition : New
Automation Grade : Automatic
Application : Human Body Checking
Feature : Accuracy, Durable, Easy To Operated, Long Life, Quality Tested
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC(Optional), CIMFR or PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
INTRINSICALLY SAFE - Vital Human Body Static Dissipator with LAMP & Resistance Display IndicationWe are engaged in offering this product to our clients. Our range Includes Human Body Static Dissipator for Discharging Static Electricity from Human Body.By Grabbing the Touch Handles of the system the person can discharrge his/her body completely , Green Indication will light up upon Sucessful Static Discharge of the human BodyAvailable in Gas Group IIA IIB IIC(Optional), CIMFR or PESOTo discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area.
Operation Principle
Human body static dissipator measures the resistance of human body and displays ‘Pass or Open’ depending on the measured value of resistance. It also provides path for static charge of the human body to discharge to earth. When human body has static charge, the resistance is typically above 1 Mega Ohm. When the human body is discharged the resistance falls below 1 Mega Ohm. When the resistance is above 1 Mega Ohm, the device displays ‘Open’. When the resistance is below 1 Mega ohm, the device displays ‘Pass’. A relay output contact is available which can be used for annunciation or interlock with the access door or gate to restrict entry of people only after static charge dissipation.
Driven Type : 230 V AC
Condition : New
Material : Aluminium
Brand Name : VITAL ENGINEERING INSTRUMENTS PVT LTD
Advanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.
...more
Flame Proof Earth Monitoring System with Resistance Display
Advanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.
Equipment Earth Monitoring SystemWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.\\nAdvanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.
Equipment Earth Monitoring SystemWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.\\nAdvanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)
We are a leading Manufacturer, Exporter, and Supplier offering the 10 Channel Earth Interlocking System - CIMFR Certified. Made from CAST IRON LM6 ALUMINIUM BODY, this system operates on 230V AC power, designed for electrical use. Our product, under the brand name VITAL ENGINEERING INSTRUMENTS, is in new condition with a durable coated finishing. Ideal for ensuring safety and reliability in electrical applications, this interlocking system is a must-have for industrial settings.
...more
10 Channel Earth Interlocking System - Cimfr Certified
We are a leading Manufacturer, Exporter, and Supplier offering the 10 Channel Earth Interlocking System - CIMFR Certified. Made from CAST IRON LM6 ALUMINIUM BODY, this system operates on 230V AC power, designed for electrical use. Our product, under the brand name VITAL ENGINEERING INSTRUMENTS, is in new condition with a durable coated finishing. Ideal for ensuring safety and reliability in electrical applications, this interlocking system is a must-have for industrial settings.
Backed by stellar customer support and a commitment to innovation, Vital Engineering Instruments sets the gold standard in keeping hazardous areas safe and compliant.
Vihar Patel
| Vadodara, Gujarat
| 19th Jul, 2024
Genuine Range of Static Earthing & Bonding Products for Hazardous areas For Earth Pit & Tanker Loading/Unloading
Atul Goyal
Anti Static Footwear Tester
| 12th Oct, 2023
One must visit the place to experience a comprehensive range of goods
Secondary Business TypeExporters / Wholesale Suppliers
Year of Establishment2016
No. of Employees6 - 20
Annual TurnoverRs. 2.5 to 5 Crore Approx.
Ownership TypeIndividual (Sole proprietorship)
GSTIN Number24AAKCV9849F1ZS
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Vital Engineering Instruments was established in the year 2016 in Vadodara, Gujarat, India. We are a manufacturer and supplier of continuous earth monitoring systems, Human body static dissipators, earthing crocodile clamps and a lot more. Core Values Leadership Be a market leader for all our products. Strive for Excellence Continuously improve business processes, products and services with a focus on how to operate more effectively, and efficiently in a user-friendly manner. Commitment Honouring our word while demonstrating moral and ethical values in conducting business at all stages. Learning & Development Enhancing the knowledge and skills of our people in everything that we do to ensure a competitive competence level in the organisation. Our Beliefs Innovative As an industry leader, we have always worked towards developing advanced technology and innovative methods. Trustworthy Our expert teams are selected specifically for each client, and each team consists of highly trained and trustworthy personnel. Reliable We are reliable to let our quality work and commitment to customer satisfaction be our slogan. Best-in-class products & services We strive to constantly innovate and improve our products & services to offer the best & become the most recognized brand in the industry. Choose to deal with us and get quality assured products from our company. Call us to know more about our products today.