Vital Engineering Instruments Makarpura, Vadodara, Gujarat

  • VITAL Human Body Static Dissipator

    VITAL Human Body Static Dissipator

    Request for Price

    1 Piece (MOQ)

    Vital Human Body Static Dissipator wit LAMP IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

    Brand Name : VITAL,Vital

    Material : CAST IRO LM

    Application : Human Body Earthing

    Type : Human Body Static Dissipator - LAMP Model

    ...more
    Get Best Price
  • VITAL Human Body Static Discharge Device

    VITAL Human Body Static Discharge Device

    Request for Price

    1 Piece (MOQ)

    Vital Human Body Static Dissipater.To discharge the static charge developed in human body to the ground, human body static dissipator provides complete solution, by measuring the resistance of human body and providing conductive path for static charge dissipation to earth. It ensures that, the human body resistance is below 1000K Ohms and safe from risk of spark generated due to static discharge, prior to entering into hazardous area. 

    Brand : VITAL

    Application : Human Body Static Earthing

    Type : Human Body Static Discharge

    Country of Origin : India

    ...more
    Get Best Price
  • Tanker Grounding Device with Alarm- DSGD-II

    Tanker Grounding Device with Alarm- DSGD-II

    Request for Price

    01 Piece (MOQ)

    The loading and unloading of tank trucks, containers, mixers etc containing flammable or combustible products has long been recognized as one of the most serious fire and explosion risks for hazardous industry operations. A study conducted by the American Petroleum Institute in 1967, for example, identified static discharges as being responsible for more than 60 incidents in tank truck loading operations, Mixing Operations, Drum Filling etc.. Since then more stringent preventive standards have been developed and significant advancements have been made in the technology of static electric discharge prevention. Yet accidents traced to static electric discharges still occur, with sometimes tragic results. The natural presence of static electricity during product transfer operations, combined with its associated ignition hazards, ensure that regulators take static control precautions for tank trucks very seriously. The primary guidelines are detailed in three primary standards: NFPA 77, API RP 2003 and   Certified as Per: Certifications - CIMFR / PESO (Optional) IP 66, Gas Group IIA IIB IIC(Optional) Complying to Standards : IS/IEC 60079-0:2007, IS/IEC 60079-11:2006

    Brand Name : VITAL

    Material : Aluminium

    Shape : Circular

    Condition : New Used

    Power Source : Electric

    Application : Tanker Static Grounding

    Certification : IS/IEC 60079:0 & IS/IEC 60079:11

    Voltage : 220V

    Display Type : Analog, Digital

    Type : Grounding Systems

    ...more
    Get Best Price
  • Static Earthing Cable Reel

    Static Earthing Cable Reel

    Request for Price

    01 Piece (MOQ)

    Material : Steel

    Application : Industrial Use

    Color : Green, Blue, Orange

    ...more
    Get Best Price
  • SS304 Static Discharge Touch Pad with LED Indication

    SS304 Static Discharge Touch Pad with LED Indication

    Request for Price

    10 Piece (MOQ)

    Static Discharge Touch Pad With LED IndicationWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients. Cold Resistance: 20 +/- 30 C Country of Origin: Made in India Brand: Vital Usage/Application: Human Body Static Discharge Model Name/Number: VITTP01-SS Type: Static Discharge Touch Pad Material: SS304   PAD Size: 30 x 30 cm

    Material : Vinyl

    Country of Origin : India

    ...more
    Get Best Price
  • Static Discharge Pole

    Static Discharge Pole

    Request for Price

    100 Piece (MOQ)

    Static Discharge Pole for human body static Discharge

    Brand : VITAL

    Material : Stainless Steel

    Country of Origin : Made In India

    ...more
    Get Best Price
  • static charge meter

    static charge meter

    Request for Price

    01 unit (MOQ)

    Country of Origin : India

    Display Type : Digital

    Operating Temperature : 0 to 40 Degree C

    ...more
    Get Best Price
  • SS Earthing Clamp with Spiral Earthing Cable

    SS Earthing Clamp with Spiral Earthing Cable

    Request for Price

    5 Piece (MOQ)

    SS Earthing Clamp with Spiral Earthing Cable 05,10,15 Metres

    Brand : Vital

    Color : Silver

    Application : Earthing

    Type : SS304 Clamp Set With Spiral Cable

    Material : SS304

    ...more
    Get Best Price
  • smart ground detector

    smart ground detector

    Request for Price

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Brand Name : VITAL

    Material : Aluminium

    Power Source : 230 V AC

    Voltage : 220V

    Display Type : Digital

    Type : Grounding Systems

    ...more
    Get Best Price
  • Smart Earth Relay Unit

    Smart Earth Relay Unit

    Request for Price

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Brand Name : VITAL,VITAL

    Material : Cast iron LM6 Alluminium

    Application : Earth Monitoring of Plant Equipments

    Feature : Earth Monitoring of Plant Equipments

    ...more
    Get Best Price
  • Continuous Earth Monitoring System with resistance Display

    Continuous Earth Monitoring System with resistance Display

    Request for Price

    01 Piece (MOQ)

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Brand Name : Vital

    Application : Tanker Loading / Unloading,Sifters,Reactors Earth Monitoring,Static Grounding

    Country of Origin : Made In India

    ...more
    Get Best Price
  • Earth Clamp with LED Visual Indication

    Earth Clamp with LED Visual Indication

    Request for Price

    01 Piece (MOQ)

    ECVI is speciality clamp Intrinsically safe with visual indication on the clamp itself. (SS304 Earth Clamp Body) It shows Green and Red indication in case of healthy and unhealthy earth connection respectively. The clamps are made of Pure SS304 Clamps with quality spring pressure and with 20.00 mm Jaw opening diameter to earth hazardous operations. The tips are made of tungsten carbide to penetrate through dust, coating, paint etc. and make a positive connection with the object. Application : To Earth Mobile Equipments, Drums, Tankers, Reactors, FDB, Sifters, Hoppers etc..   Certified as Per: IS/IEC 60079-0:2007IS/IEC 60079-11:2006IS/IEC 60529:2001 Marking on Equipment -Ex ib IIb Gb T4 ( 0to < Ta < +50)

    Size : 6-9 Inch(Clamp)

    Brand Name : Vital

    Material : Stainless Steel

    Application : Earthing

    Country of Origin : India

    Current Rating : 300 - 500 Amps

    ...more
    Get Best Price
  • Continuous Earth Monitoring System with Resistance Display and Hooter

    Continuous Earth Monitoring System with Resistance Display and Hooter

    Request for Price

    01 Piece (MOQ)

    FLP/WP Advanced Continuous Earthing Monitoring System with HooterWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

    Material : FLP - LM6 Aluminium Alloy

    Country of Origin : India

    ...more
    Get Best Price
  • Earth Inter Lock System ILS-0621

    Earth Inter Lock System ILS-0621

    Request for Price

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Brand Name : VITAL

    Material : Cast iron LM6 Alluminium

    Application : Earthing Continuity

    Warranty : 1year

    Country of Origin : India

    ...more
    Get Best Price
  • Intelligent Road Tanker Static Grounding System

    Intelligent Road Tanker Static Grounding System

    Request for Price

    01 piece (MOQ)

    Modes Of Operation Road tanker identification – the processes of loading or unloading of a road tanker are only possible if the system: It has been attached to a road tanker and not to another structure or metal object, It has been connected to the vehicle’s component that allows electrostatic charges to be discharged from the tanker tank. Earth electrode verification – checking if the earth electrode (e.g. steel tape) ensures fast and safe dissipation of electric charges to the ground. Continuous monitoring of the connection between the road tanker and the ground – if the connection is lost (loose clasp, damaged pipes, etc.), the tanker loading/ unloading process will be blocked.

    Brand Name : VITAL

    Material : Aluminium, FLP - LM6 & SS304 Body

    Power Source : Electric

    Certification : IS/IEC 60079:0 & IS/IEC 60079:11

    Voltage : 220V

    Display Type : Analog

    Country of Origin : India

    ...more
    Get Best Price
  • Human Body Voltage Checker

    Human Body Voltage Checker

    Request for Price

    1 Piece (MOQ)

    Automation Grade : Automatic

    Feature : Accuracy, Alarm Indicator, Easy To Operated

    Type : ESD Instrument

    Country of Origin : India

    Brand Name : Vital

    ...more
    Get Best Price
  • Flame Proof Earth Monitoring System with Resistance Display

    Flame Proof Earth Monitoring System with Resistance Display

    Request for Price

    01 Piece (MOQ)

    Advanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.Certified as Per:IS/IEC 60079-0:2007IS/IEC 60079-11:2006IS/IEC 60529:2001Marking on Equipment: Ex d[ib] IIb T6 Gb (-10 to <Ta< +50) 

    Country of Origin : Made In India

    ...more
    Get Best Price
  • Earthing Crocodile Clamp

    Earthing Crocodile Clamp

    Request for Price

    10 Piece (MOQ)

    Country of Origin : Made in India

    Get Best Price
  • Earth-Rite Tanker Earthing System - PESO Approved

    Earth-Rite Tanker Earthing System - PESO Approved

    Request for Price

    01 Piece (MOQ)

    WORKING PRINCIPLE (Tri-mode Technology) MODE 1 & 2 II With the grounding clamp and cable attached to the designated earth point on the road tanker through its patented circuitry the System detects the presence of the road tanker by its capacitance and not by impedance, resistance or the presence of a diode on the road tanker. At the same time the patented circuitry ensures that it has a connection to the general mass of the earth. This is a critical step as a connection to earth is the only means by which the static electricity can be transferred from the teeth of the clamp on the road tanker to earth thereby mitigating the accumulation of static electricity during the transfer. MODE 3 II Once Modes 1 and 2 have been completed successfully the patented circuitry monitors the loop resistance from between the teeth of the clamp on the road tanker to the designated general mass of the earth through the System Ground connections. The circuitry will monitor the loop resistance and if it exceeds 10 Ohms it will stop the transfer. ATTENTION II Driver / operator training is essential for the correct use of the grounding system. The first action in the material transfer process is grounding of the road tanker. The System clamp should be connected directly to the designated earthing point of the road tanker. The grounding clamp should NOT be removed until all other procedures in the material transfer process are complete. Dry Contacts II The System output contacts can be interlocked with process equipment and/or strobes. Interlocking the grounding system with the process equipment can enhance the Standard Operating Procedures (SOP) before the movement of material can take place. Interlocking with strobes provides personnel with a wider field of view that the grounding SOP is underway. On rare occasions grounding clamps can be removed by operators or lose contact with equipment due to unstable connections being made initially or overstretching of the cable connected to the grounding clamp. The grounding system, can, via the output contacts, halt the process. However, it should be borne in mind that the movement of the product may not stop even though the equipment (pump / impeller) has halted. This could lead to the continued generation of static charge. In such circumstances it is the responsibility of the site operator to ensure their SOPs cater for such scenarios. This assumes the grounding system has been installed in accordance with the Instruction Manual.

    Brand Name : VITAL

    Material : Aluminium, FLAMEPROOF

    Condition : New Used

    Power : 10w

    Feature : Corrosion Proof, Excellent Quality, High Strength, Sturdy Design

    Type : Grounding Systems

    Warranty : 1Years

    Country of Origin : India

    ...more
    Get Best Price
  • Flameproof Earth Monitoring System

    Flameproof Earth Monitoring System

    Request for Price

    01 Piece (MOQ)

    Equipment Earth Monitoring SystemWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients. Advanced Tanker / Drum Static Earthing & Gronding SystemThe Tanker earthing system With adjustable monitoring resisatnce is designed to discharge all the static charge to ground once it makes the positive Connection to the tanker body. The System will monitor the resistance between the tanker body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or if there is discontinuity in the ground connection.Certified as Per:IS/IEC 60079-0:2007IS/IEC 60079-11:2006IS/IEC 60529:2001Marking on Equipment:   Ex d[ib] IIb T6 Gb (-10 to <Ta< +50) 

    Brand Name : VITAL

    Country of Origin : Made In India,Made In India

    ...more
    Get Best Price
  • Earth Monitoring & Interlocking System

    Earth Monitoring & Interlocking System

    Request for Price

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Material : FLP/GMP,FLP - LM6 & SS304 Body

    Power : 10W

    Country of Origin : Made In India

    Driven Type : Electric

    ...more
    Get Best Price
  • Earth Confirmation Relay

    Earth Confirmation Relay

    Request for Price

    The process of filling inflammable liquids for transportation or storage, safety standards and procedures must ensure that the static voltage which occurs during this process, should not lead to an explosion. To handle this static voltage, the vehicle or the container should be properly earthed. This is important so that the static voltage does not build up to a dangerous flash point . The Earthing method should be proper and perfect, otherwise dangerous losses can take placeWORKING PRINCIPLETHE System should be used to monitor the earthing of the vehicle, static equipments, once connected it shows the actual earthing status with GREEN & RED IndicationGREEN INDICATION – HEALTHY EARTH - Loading / Unloading Process should Start or it gets automatically started through relay contactsRED INDICATION – UNHEALTHY EARTH Loading / Unloading Process should stop or it gets automatically stopped through relay contactsExtra Features Like Resistance Display, Hooter, Adjustable Monitoring Resistance availble (Optional)

    Brand Name : VITAL

    Material : Aluminium

    Type : Grounding Systems

    Warranty : 1Years

    ...more
    Get Best Price
  • SS304 Earth Clamps

    SS304 Earth Clamps

    Request for Price

    Crocodile Earthing ClampsWe are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

    Size : 6 Inches. 9 Inches

    Brand : VITAL

    ...more
    Get Best Price
  • 20 Channel Continuous Earth Monitoring System CEMS-20/RM/0521

    20 Channel Continuous Earth Monitoring System CEMS-20/RM/0521

    Request for Price

    01 Piece (MOQ)

    The Multi Channel Earthing system is designed to discharge all the static charge to ground once it makes the positive connection to all the connected equipments The System will monitor the resistance between the equipment body and earth for <10 ohms and it will automatically shut down the process if resistance increases beyond 10 ohms or there is discontinuity in the ground connection (Interlocks Provided Optional) The System has also facility to adjustable Monitoring resistance The System has an additional feature that it displays Individual Channel Earth Resistance with respect to ground in Ohms on Screen along with Green & Red Earth Status Indication. Application : To Earth & Monitor upto 20 Multiple Equipments like Drums, Tankers, Reactors, FDB, Sifters, Hoppers etc..   Certified as Per: Certifications - CIMFR / PESO (Optional)- FLP Certified & IP 66 Complying to Standards : IS/IEC 60079-0:2007, IS/IEC 60079-11:2006Continuous Earth Monitoring System CEMS-20/RM/0521 II 20 Channel Continuous Earth Monitoring System II  Multi Channel Continuous Earth Monitoring System II  Multi Channel Earth Loop Monitoring System II 20 Channel II  CEMS 2021 II VITAL ENGINEERING INSTRUMENTS II Continuous Earth Monitoring System (CEMS - 0313)Continuous Earth Monitoring System CEMS-20/RM/0521

    Power Supply : 230 V AC

    Brand : VITAL

    Country of Origin : India

    ...more
    Get Best Price

Average Customer Rating


5 / 5

Business Rating


5 1
4 0
3 0
2 0
1 0
Write a Review

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Manufacturers
  • Secondary Business Type Exporters / Wholesale Suppliers
  • Year of Establishment 2012
  • No. of Employees Below 20
  • Annual Turnover Rs. 2.5 to 5 Crore Approx.
  • Ownership Type Individual (Sole proprietorship)

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Vital Engineering Instruments was established in the year 2016 in Vadodara, Gujarat, India. We are a manufacturer and supplier of continuous earth monitoring systems, Human body static dissipators, earthing crocodile clamps and a lot more.
Core Values
Leadership
Be a market leader for all our products.
Strive for Excellence
Continuously improve business processes, products and services with a focus on how to operate more effectively, and efficiently in a user-friendly manner.
Commitment
Honouring our word while demonstrating moral and ethical values in conducting business at all stages.
Learning & Development
Enhancing the knowledge and skills of our people in everything that we do to ensure a competitive competence level in the organisation.
Our Beliefs
Innovative
As an industry leader, we have always worked towards developing advanced technology and innovative methods.
Trustworthy
Our expert teams are selected specifically for each client, and each team consists of highly trained and trustworthy personnel.
Reliable
We are reliable to let our quality work and commitment to customer satisfaction be our slogan.
Best-in-class products & services
We strive to constantly innovate and improve our products & services to offer the best & become the most recognized brand in the industry.
Choose to deal with us and get quality assured products from our company. Call us to know more about our products today.
Read More »

Contact Information

Vital Engineering Instruments

top