SensitivityHigh power of emission & broadband of receiving sensitivity
Unit Selectionmm & inch Swichable
Material Type11 types of material
Material SelectionBy Switch
Sensor Head8mm Diameter x 28mm (34” Sensor Cord Length)
Calibration BlockProvided
AccessoriesCarrying case, Oil Sachet
Aux. Supply4 x 1.5V AA Size Battery
Cabinet Size161 X 69 X 32mm ABS Plastic
Suitable for measuring thickness of Pipes, Rods, Plates, etc. of material like steel, cast iron, aluminium, red copper, brass, zinc, quartz glass, polyethylene, PVC, gray cast iron, nodular cast iron, etc.
Suitable for measuring thickness of Pipes, Rods, Plates, etc. of material like steel, cast iron, aluminium, red copper, brass, zinc, quartz glass, polyethylene, PVC, gray cast iron, nodular cast iron, etc.
Suitable for determining the indentation hardness of materials from soft rubber to rigid plastics. Shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like materials such as neoprene, silicone, vinyl, soft plastics, felt, leather & similar materials. Shore D is designed for plastics, formica, epoxies & plexiglass, etc.
Suitable for determining the indentation hardness of materials from soft rubber to rigid plastics. Shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like materials such as neoprene, silicone, vinyl, soft plastics, felt, leather & similar materials. Shore D is designed for plastics, formica, epoxies & plexiglass, etc.
Suitable for measuring moisture content of craft paper, paper reel, waste paper bale, cartons, paper board, corrugated rolls & Sheets, paper pallets, paper containers, paper tubes, paper cones, paper cores, Copperplate Paper, Writing Paper.
Suitable for measuring moisture content of craft paper, paper reel, waste paper bale, cartons, paper board, corrugated rolls & Sheets, paper pallets, paper containers, paper tubes, paper cones, paper cores, Copperplate Paper, Writing Paper.
FEATURES:4-20mA (1KΩ load, 24V Loop Supply)0-100.00mV, 0-1.000V, 0-12.000VK, J, E, T Thermocouple (° C and ° F)Frequency 1-62500 Hz0.025% Basic AccuracyEasy Keypad OperationEasy Step and Auto Ramp Functions0-20mA, 0-24mA selectable0-100% Input (mA, mV, V)Beeper warning when output is open (mA) or short (mV, V)
FEATURES:4-20mA (1KΩ load, 24V Loop Supply)0-100.00mV, 0-1.000V, 0-12.000VK, J, E, T Thermocouple (° C and ° F)Frequency 1-62500 Hz0.025% Basic AccuracyEasy Keypad OperationEasy Step and Auto Ramp Functions0-20mA, 0-24mA selectable0-100% Input (mA, mV, V)Beeper warning when output is open (mA) or short (mV, V)
Range
1 micro ohms to 19.99 K ohms in 8 full scale ranges of 0-1999 micro ohms, 0-19.99 milli ohms, 0-199.9 milli ohms, 0-1999 milli ohms, 0-19.99 ohms, 0-199.9 ohms, 0-1999 ohms and 0-19.99 K ohms
Resolution
1 micro ohms in 1999 micro ohms range, 0.01milli ohms 19.99 milli ohms range, 0.1milli ohms in 199.9 milli ohms range, 1 milli ohms in 1999 milli ohms range, 0.01 ohms in 19.99 ohms range, 0.1 ohms in 199.9 ohms range, 1 ohm in 1999 ohms in 19.99 K ohms range
Accuracy
± 0.2 % ± 2 least counts in all ranges
except in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges. ±0.5% +_ 3 least count in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges
Test Current
1 Amp DC in 1999 micro ohms, 19.99 milli ohms, 199.9 milli ohms and 1999 milli ohms ranges. 0.1 amp DC in 19.99 ohms range, 10 milli amp DC in 199.9 ohms range, 1 milli amp DC in ohms range, 0.1 milli amp DC in 19.99 K ohms range
Range
1 micro ohms to 19.99 K ohms in 8 full scale ranges of 0-1999 micro ohms, 0-19.99 milli ohms, 0-199.9 milli ohms, 0-1999 milli ohms, 0-19.99 ohms, 0-199.9 ohms, 0-1999 ohms and 0-19.99 K ohms
Resolution
1 micro ohms in 1999 micro ohms range, 0.01milli ohms 19.99 milli ohms range, 0.1milli ohms in 199.9 milli ohms range, 1 milli ohms in 1999 milli ohms range, 0.01 ohms in 19.99 ohms range, 0.1 ohms in 199.9 ohms range, 1 ohm in 1999 ohms in 19.99 K ohms range
Accuracy
± 0.2 % ± 2 least counts in all ranges
except in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges. ±0.5% +_ 3 least count in 200 milli ohms, 20 milli ohms and 2000 micro ohms ranges
Test Current
1 Amp DC in 1999 micro ohms, 19.99 milli ohms, 199.9 milli ohms and 1999 milli ohms ranges. 0.1 amp DC in 19.99 ohms range, 10 milli amp DC in 199.9 ohms range, 1 milli amp DC in ohms range, 0.1 milli amp DC in 19.99 K ohms range
Secondary Business TypeManufacturer / Exporters / Wholesale Suppliers
Year of Establishment2004
No. of Employees6 - 20
Annual TurnoverBelow Rs. 0.5 Crore Approx.
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Source1 Established in 2004 is Retailer of Analytical Instrum, Electrical Measuring Meters, Proces Control Instruments, Temperature Instruments, Digital Multimeter, Digital Clamp Meter, Digital Insulation Tester, Paper Moisture Meter, Thermo Anemometer, Digital Lux Meter in Vapi, Gujarat.