A) PVC/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 1 300/500v
Polyvinyl Chloride Insulated Polyvinyl Chloride Sheathed Overall Screened Instrument Cable
Description:
Single pair and multi-pair cables with copper conductor, PVC insulated, overall screened and PVC sheathed. Voltage rated at 300/500V.
Construction
Conductor:Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
Insulation:PVC (Polyvinyl Chloride) / PE
Pairing:Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.Note: Two pair cables with overall screen shall have four cores laid in quad formation.
Pair identification:Colour code as per Appendix B or as per customer specification
Cabling:Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation.
Overall Screening:Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
Sheath:PVC (Polyvinyl Chloride).
B) PVC/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 1 300/500v
Polyvinyl Chloride Insulated Polyvinyl Chloride Sheathed Individual & Overall Screened Instrument Cable
Description
Multi-pair cables with copper conductor, PVC insulated, individual & overall screened and PVC sheathed. Voltage rated at 300/500V.
Construction
Conductor:Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
Insulation:PVC (Polyvinyl Chloride) / PE
Pairing:Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.Note: Two pair cables with overall screen shall have four cores laid in quad formation.
Pair identification:Colour code as per Appendix B or as per customer specification
Individual Screening:Each pair screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
Cabling:Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
Overall Screening:Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
Sheath:PVC (Polyvinyl Chloride).
C) PVC/PVC/SWA/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 2 300/500v
Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Overall Screened Instrument Cable
Description:
Single pair and multi-pair cables with copper conductor, PVC insulated, overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V
Construction
Conductor:Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
Insulation:PVC (Polyvinyl Chloride) / PE
Pairing:Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.Note: Two pair cables with overall screen shall have four cores laid in quad formation.
Pair identificationColour code as per Appendix B or as per customer specification
CablingTwisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
Overall ScreeningAccumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
BeddingPVC (Polyvinyl Chloride).
ArmouringGalvanized steel round wire over the bedding.
SheathPVC (Polyvinyl Chloride).
D) PVC/PVC/SWA/PVC Individual & Overall Screened Instrument Cable BS 5308 Part 2 : Type 2 300/500v
Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Individual & Overall Screened Instrument Cable
Description
Multi-pair cables with copper conductor, PVC insulated, individual & overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V
Construction
ConductorPlain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
InsulationPVC (Polyvinyl Chloride) / PE
PairingTwo insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.
Pair identificationColour code as per Appendix B or as per customer specification
Individual ScreeningEach pair screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
CablingTwisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
Overall ScreeningAccumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
BeddingPVC (Polyvinyl Chloride).
ArmouringGalvanized steel round wire over the bedding.
SheathPVC (Polyvinyl Chloride)