Maximum rating up to 1200 kV to test UHV Instrument transformers. High precision measurement features in Power Capacitor Quality Assurance. High resolution tan delta down to 1ppm with high accuracy measurement. When interfaced with range extension CT and High precision Standard capacitor the instrument has wide application among electrical testing of HV Power Appliances.
Maximum rating up to 1200 kV to test UHV Instrument transformers. High precision measurement features in Power Capacitor Quality Assurance. High resolution tan delta down to 1ppm with high accuracy measurement. When interfaced with range extension CT and High precision Standard capacitor the instrument has wide application among electrical testing of HV Power Appliances.
Well trusted, highly rugged, very fast, on line Power Capacitor, Capacitance & tan d meter for final checking of LT power capacitors. High Accuracy meter serves almost all Power Capacitor Industries in India. Fully Automated system for man free operation is also available.
...more
Rated Voltage Rated Current LT Power Capacitor Testing
Well trusted, highly rugged, very fast, on line Power Capacitor, Capacitance & tan d meter for final checking of LT power capacitors. High Accuracy meter serves almost all Power Capacitor Industries in India. Fully Automated system for man free operation is also available.
Its sensor senses the radiated field which surrounds live conductors. Radiated field strength increases with voltage and decreases quickly with distance or earth shielding. The radiated field from a cable of closely bunched conductors supplied by three phase power tends to cancel (See "Limitations of use" paragraph). Detecting distance of a 250Vac single live wire is approximately 10cm. With a bunched neutral and earth cable, as in a flexible cable, the distance is reduced to 5cm.
Its sensor senses the radiated field which surrounds live conductors. Radiated field strength increases with voltage and decreases quickly with distance or earth shielding. The radiated field from a cable of closely bunched conductors supplied by three phase power tends to cancel (See "Limitations of use" paragraph). Detecting distance of a 250Vac single live wire is approximately 10cm. With a bunched neutral and earth cable, as in a flexible cable, the distance is reduced to 5cm.
Micro Ohm Meter.4 wire kelvin clip Micro Ohm meter has the resolution down to 1 micro Ohm, Best current of 1 A best protections in the class, rugged, Micro processor controlled, over current, over temperature protection.
Milli Ohm MeterKelvin clip, high accuracy of 0.5% is established in 100 mA, the best resolution of 0.1 mOhm meter. Over temperature protection, advert current protection,
Micro Ohm Meter.4 wire kelvin clip Micro Ohm meter has the resolution down to 1 micro Ohm, Best current of 1 A best protections in the class, rugged, Micro processor controlled, over current, over temperature protection.
Milli Ohm MeterKelvin clip, high accuracy of 0.5% is established in 100 mA, the best resolution of 0.1 mOhm meter. Over temperature protection, advert current protection,
To avoid Power Frequency test on earthed cables, the testing of damped AC voltage and Low Voltage VLF test is preferred. Model DAC-LFM-3 is the very pure non distractive test set for finding the fault in the cable. The capacitance of the cable is measured with high precision
To avoid Power Frequency test on earthed cables, the testing of damped AC voltage and Low Voltage VLF test is preferred. Model DAC-LFM-3 is the very pure non distractive test set for finding the fault in the cable. The capacitance of the cable is measured with high precision
We promote the clamp meters which are the leakage detectors too. The leakage detectors ranging from 20 mA and above are available from us. Clamp Meter of 400 A, 600 A 1000A Leakage detector in the electric equipment, Electric Circuit are offered from us.
We promote the clamp meters which are the leakage detectors too. The leakage detectors ranging from 20 mA and above are available from us. Clamp Meter of 400 A, 600 A 1000A Leakage detector in the electric equipment, Electric Circuit are offered from us.
Detecting the Insulation Quality of Transformer, IT, HT Motor and Generator, any HT set up, by applying DC voltage. Voltage rating from 250 V, 500Vand 1 kV is available in various ranges. Very handy equipment meeting the standard requirement for Detecting PI, DAR. Insulation resistance Measurement. Continuity testing and other features like voltage measurements are incorporated in some models. LV Insulation Resistance meters up to 1 kV are also available in Analog type. Digital HV Insulation Resistance meters are available up to 15 kV class.
Detecting the Insulation Quality of Transformer, IT, HT Motor and Generator, any HT set up, by applying DC voltage. Voltage rating from 250 V, 500Vand 1 kV is available in various ranges. Very handy equipment meeting the standard requirement for Detecting PI, DAR. Insulation resistance Measurement. Continuity testing and other features like voltage measurements are incorporated in some models. LV Insulation Resistance meters up to 1 kV are also available in Analog type. Digital HV Insulation Resistance meters are available up to 15 kV class.
Resolution of The set, DAC-IM-D6, measures capacitance and the dielectric loss tangent (tan d) of electrical insulating materials with a resolution of 1 ppm (1 × 10-6). It allows measurement of tan d of liquid, film, paper, electric tape, insulating plate and other items with use of liquid, sheet or other appropriate electrodes for the sample materials under test in accordance with the IEC (60247, 60554-2) and JIS (C2101) Standards. The set also allows measurement of capacitance simultaneously with tan d and thus, it provides dielectric constant measurements of materials.
Resolution of The set, DAC-IM-D6, measures capacitance and the dielectric loss tangent (tan d) of electrical insulating materials with a resolution of 1 ppm (1 × 10-6). It allows measurement of tan d of liquid, film, paper, electric tape, insulating plate and other items with use of liquid, sheet or other appropriate electrodes for the sample materials under test in accordance with the IEC (60247, 60554-2) and JIS (C2101) Standards. The set also allows measurement of capacitance simultaneously with tan d and thus, it provides dielectric constant measurements of materials.
• Measuring Range :0 – 150 kV IMPULSE PEAK (can be extended as per customer requirement)
Ratio500
Accuracy1% of the reading
Feature• Direct reading in kV.• Measurement of ‘Positive’ and ‘Negative’ Impulse Voltages.• 3½ Digit LED-Display.• Terminal for oscilloscope connection to observe Impulse wave shape.
Technical • Power Supply : 220V±10%, 50Hz • Measuring Range : 0 – 150 kV IMPULSE PEAK (can be extended as per customer requirement) • Ratio : 500 • Accuracy : 1% of the reading • Resolution : 0.1 kV • Freq. of operation : 50 Hz • Voltage at : 0 – 300 V for 0 – 150 kV display
Feature• Direct reading in kV.• Measurement of ‘Positive’ and ‘Negative’ Impulse Voltages.• 3½ Digit LED-Display.• Terminal for oscilloscope connection to observe Impulse wave shape.
Technical • Power Supply : 220V±10%, 50Hz • Measuring Range : 0 – 150 kV IMPULSE PEAK (can be extended as per customer requirement) • Ratio : 500 • Accuracy : 1% of the reading • Resolution : 0.1 kV • Freq. of operation : 50 Hz • Voltage at : 0 – 300 V for 0 – 150 kV display
The NEW PC range of Multifunction Phasing Sticks utilizes a long established technique to detect and measure High Voltages and perform phasing tests. These Dual Poles instruments incorporates modern, high quality glass fiber front end, composite polyurethane main body molding to give tough and very light weight construction and superior safety features. They have Analog Color Coded Dual Scales and Neon indication.
The NEW PC range of Multifunction Phasing Sticks utilizes a long established technique to detect and measure High Voltages and perform phasing tests. These Dual Poles instruments incorporates modern, high quality glass fiber front end, composite polyurethane main body molding to give tough and very light weight construction and superior safety features. They have Analog Color Coded Dual Scales and Neon indication.
Feature• Optically Isolated Measurement• Direct reading in kV.• Measurement of Peak, Peak/√2, RMS Voltages.• 3½ Digit LED-Display.• Terminal for oscilloscope connection to observe High voltage wave shape
Technical • Power Supply : 220V±10% 50Hz • Measuring Range : 0 – 100 kV RMS (can be extended as per customer requirement) • Accuracy : 0.5% of the reading • Resolution : 0.1 kV • Freq. Response : 40 Hz to 1 kHz• Voltage O/p for reading: 0 – 10V for 0 – 100 kV display
Feature• Optically Isolated Measurement• Direct reading in kV.• Measurement of Peak, Peak/√2, RMS Voltages.• 3½ Digit LED-Display.• Terminal for oscilloscope connection to observe High voltage wave shape
Technical • Power Supply : 220V±10% 50Hz • Measuring Range : 0 – 100 kV RMS (can be extended as per customer requirement) • Accuracy : 0.5% of the reading • Resolution : 0.1 kV • Freq. Response : 40 Hz to 1 kHz• Voltage O/p for reading: 0 – 10V for 0 – 100 kV display
Measuring Range :0 – 100 kV (can be extended as per customer requirement)
Accuracy0.5% of the reading
Feature• Direct reading in kV.• 3½ Digit LED-Display.• terminal for oscilloscope connection to observe High voltage wave shape.
Technical Data•Power Supply : 220V±10% 50Hz • Measuring Range : 0 – 100 kV (can be extended as per customer requirement) • Accuracy : 0.5% of the reading • Resolution : 0.1 kV • Voltage at : 0 – 10 V for 0 – 100 kV display
Feature• Direct reading in kV.• 3½ Digit LED-Display.• terminal for oscilloscope connection to observe High voltage wave shape.
Technical Data•Power Supply : 220V±10% 50Hz • Measuring Range : 0 – 100 kV (can be extended as per customer requirement) • Accuracy : 0.5% of the reading • Resolution : 0.1 kV • Voltage at : 0 – 10 V for 0 – 100 kV display
This instrument is useful for fault-finding or commissioning of electrical installations. Differentiation between the Line (hot), Neutral and Earth (ground) path by reading their values has never been so easy. Bad contacts, old wiring or bad earth path are quickly identified. Faulty electrical network can be resolved in a fraction of the time normally required using conventional equipment.
This instrument is useful for fault-finding or commissioning of electrical installations. Differentiation between the Line (hot), Neutral and Earth (ground) path by reading their values has never been so easy. Bad contacts, old wiring or bad earth path are quickly identified. Faulty electrical network can be resolved in a fraction of the time normally required using conventional equipment.
We offer Analog and Digital earth Resistance meters. Resolutions well below 0.01 Ohm are very popular Earth Resistance Meters meeting the International Standards.
We offer Analog and Digital earth Resistance meters. Resolutions well below 0.01 Ohm are very popular Earth Resistance Meters meeting the International Standards.
Wide application partial discharge test system for Testing Power Cable, Transformer, Rotating Machines. Narrow and Broad band selection, Qmax, PPS etc. Digital Sampling , Free selection of frequency band, Identification of PD source, Pulse Polarity are unque features.
Wide application partial discharge test system for Testing Power Cable, Transformer, Rotating Machines. Narrow and Broad band selection, Qmax, PPS etc. Digital Sampling , Free selection of frequency band, Identification of PD source, Pulse Polarity are unque features.
High Frequency Discharges coming out of HID lamps are possible to detect using our products the voltage up to 70 kV of high frequency in nature are detected by our probes and testing done by the generators. The corona detectors to check the inductance of the On line oat
High Frequency Discharges coming out of HID lamps are possible to detect using our products the voltage up to 70 kV of high frequency in nature are detected by our probes and testing done by the generators. The corona detectors to check the inductance of the On line oat
GST Mode testing is made direct, eliminating the stray capacitance. Only equipment in the universe, which directly measures capacitance & tan delta of grounded objects like motor, generator, transformer. Perfect equipment for testing generator of 27 kV class even up to 40 kV.
GST Mode testing is made direct, eliminating the stray capacitance. Only equipment in the universe, which directly measures capacitance & tan delta of grounded objects like motor, generator, transformer. Perfect equipment for testing generator of 27 kV class even up to 40 kV.