Thermal Conductivity Tester Dealers in Delhi

(4 products available)
  • Thermal Conductivity Tester

    Thermal Conductivity Tester

    Get Price Quote

    • Frequency: 50Hz
    • Application: Lab
    • Size: 300 x 300 mm
    • Power Supply: 220 V
    • Measuring Range: 40-150 Degree Celcius
    • Conductivity Range: 0.05
    • Heating Power: 35 W
    more..
  • Thermal Conductivity Tester

    Thermal Conductivity Tester

    Get Price Quote

    • Capacity: 5 MJ/m³K.
    • Temperature Range: -253 °C to 1000 °C.
    • Dimensions: 0.042 mm × 8 mm diameter or square for slab testing,5 mm × 2.5 mm diameter or square for one-dimensi

    thermal diffusivity and specific heat. The capabilities of TPS 3500 go well beyond that of any other Hot Disk instrument to date, Automatic Temperature series measurements (Isothermal Steps) are easy to perform using either an optional external Furnace or a temperature-controlled Circulating Bath. These external devices can be directly controlled through the Hot Disk Thermal Analyser software to ensure ease of use.The basic TPS 3500 system includes everything to allow you to begin making measurements, including installation and on-site training. The system includes: Hot Disk TPS 3500 instrument; Isotropic, One-dimensional and Structural Probe measurement modules; a Sensor; Insulating Support-Material for Single-Sided testing; Stainless Steel Verification Samples and Room-Temperature Sample Holder.

    more..
  • Best Deals from Thermal Conductivity Tester

  • Thermal Conductivity Tester

    Thermal Conductivity Tester

    Get Price Quote

    Value at mean temperature as per IS: 3346 – 1980. Testing of K value of Mineral wool insulation, Polypro ethane foam, expended Polystyrene, test is required to be done at a constant temperature of 0° to (-)10°C. Two slab guarded Hot Plate Method. Hot face Max. temperature (+99°C) Hot face Min. temperature (+60°C) Cold face max. temperature (+60°C) Cold face min. temperature (-10°C) Specimen size to be tested 300 m.m. X 300 m.m. Thickness 50 m.m. The above parameters will limit the testing range from 30°C to 99°C mean temperature. Water circulation system. Insulated Box with viewing window. The system also incorporated with accidental protection devices. thyrestorized firing heat control Designed as per IS: 3346 – 1980 Hot plate method. 2. Microprocessor based testing system consist of followings. 8 Channel scanner with all input flashing as per the pre programmed interval. Options: A computer with Powerlog software with necessary printer output will be there on the instruments. Thermal conductivity value to be calculated and as per the formula provided in our instruction manual. Hot plate system has got digital control for guard heater Temperature, needs only power supply and a few liters of water to operate. Stabilized voltage control system (Power Module) servo assisted To keep the voltage ±1 Volts. Center Heater size:- 153 m.m. X 153 m.m. Specimen size to be tested – 300 m.m. X 300 m.m. Thickness: 50 m.m. Horizontal system. The ambient temperature of 27°C ±1C to be maintained by user.

    more..
  • Thermal Conductivity Tester

    Get Price Quote

    Thermal Conductivity Tester, Thermal Conductivity Analyzer

    more..
Filter by Locality