These kind of transformers are used for testing applications where variable output is required from 0 to any voltage. These kind of transformers are widely used in transformer motor generator manufacturing units to perform various electrical tests.
These kind of transformers are used for testing applications where variable output is required from 0 to any voltage. These kind of transformers are widely used in transformer motor generator manufacturing units to perform various electrical tests.
We are offering ups.
A ups is typically used to protect computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss.
We are offering ups.
A ups is typically used to protect computers, data centers, telecommunication equipment or other electrical equipment where an unexpected power disruption could cause injuries, fatalities, serious business disruption or data loss.
Technical Specifications
System Connections : Delta Star or Star Delta or Star Star
Ratios : 1:1 and 2:1
Regulation : Better than 3.5 %
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 3KV for 60 sec
Insulation Resistance : Better than 1000Mega Ohms
Coupling Capacitance : 0.01 PF for 100 Db
Technical Specifications
System Connections : Delta Star or Star Delta or Star Star
Ratios : 1:1 and 2:1
Regulation : Better than 3.5 %
Power Factor : 0.75 Lead to 0.75 Lag
Di-electric Strength : 3KV for 60 sec
Insulation Resistance : Better than 1000Mega Ohms
Coupling Capacitance : 0.01 PF for 100 Db
Servomax India Ltd takes pride in providing excellent solutions to all kinds of Power problems. We recognize your company as one of the leaders in the field of Electronic Industry. We understand your aims of bringing out the best products in present competitive market.
Servomax India Ltd takes pride in providing excellent solutions to all kinds of Power problems. We recognize your company as one of the leaders in the field of Electronic Industry. We understand your aims of bringing out the best products in present competitive market.
Features
Individual phase control and bypass protection
It is a custom built item which can be manufactured with required dimensions
Single stabilizer would serve all the domestic needs.
Quick servicing and maintenance free
Suitable for 3 phases and single phase applications
It is a power saving device and reduces excess power consumption
Available for all the load requirements
Features
Individual phase control and bypass protection
It is a custom built item which can be manufactured with required dimensions
Single stabilizer would serve all the domestic needs.
Quick servicing and maintenance free
Suitable for 3 phases and single phase applications
It is a power saving device and reduces excess power consumption
Available for all the load requirements
A Power Saver is a device which you plug in to your power socket. Apparently just by keeping the device connected it will immediately reduce your power consumption. Typical claims are savings between 25% and 40%.
A Power Saver is a device which you plug in to your power socket. Apparently just by keeping the device connected it will immediately reduce your power consumption. Typical claims are savings between 25% and 40%.
Technical Specifications
Double wound, High Isolation.
Double sized neutral.
Insulation class “H”.
Regulation is better than 3.5%.
Overload rating of 100% for 10 secs.
Core of CRGO and conductor of copper.
Natural Forced Air Cooled.
Technical Specifications
Double wound, High Isolation.
Double sized neutral.
Insulation class “H”.
Regulation is better than 3.5%.
Overload rating of 100% for 10 secs.
Core of CRGO and conductor of copper.
Natural Forced Air Cooled.
This transformer completely isolates all the circuits and then supplies power individually which makes it all the more desirable and comprehensive. An isolation transformer does not have a direct electrical path from the power input side to the power output side their design is based more on the requirements of the user. So, in a way you can say that they are customized transformers.
This transformer completely isolates all the circuits and then supplies power individually which makes it all the more desirable and comprehensive. An isolation transformer does not have a direct electrical path from the power input side to the power output side their design is based more on the requirements of the user. So, in a way you can say that they are customized transformers.
Servomax has a wide range of isolation transformers which reduce the effects of power line problems like noise, spikes, surges, transients and neutral, to a minimum.
Servomax has a wide range of isolation transformers which reduce the effects of power line problems like noise, spikes, surges, transients and neutral, to a minimum.
In spite of best efforts, no state electricity board can ensure constant voltage to the customer because of long and inadequate distribution lines and irregular load pattern on distribution transformers. Generally Voltage is low during day time and high during night hours. Moreover on holidays, peak hours, rainy days and when agricultural and Industrial load is switched off, the voltage rises sharply which is more dangerous.
In spite of best efforts, no state electricity board can ensure constant voltage to the customer because of long and inadequate distribution lines and irregular load pattern on distribution transformers. Generally Voltage is low during day time and high during night hours. Moreover on holidays, peak hours, rainy days and when agricultural and Industrial load is switched off, the voltage rises sharply which is more dangerous.
SERVOMAX make Transformers with built-in rolling contact type AVR suitable for indooroutdoor installation, copper wound HT Two-in-one system is a revolutionary landmark in the industry when it comes to voltage regulation and stabilization.
SERVOMAX make Transformers with built-in rolling contact type AVR suitable for indooroutdoor installation, copper wound HT Two-in-one system is a revolutionary landmark in the industry when it comes to voltage regulation and stabilization.
SERVOMAX Make Copper wound, HT AVR suitable for indoor outdoor installation, copper wound HT AVR system is a revolutionary landmark in the industry when it comes to voltage regulation and stabilization. Even after the installation of standard distribution transformer the problem of low high voltage on the LT loss of a plant.
SERVOMAX Make Copper wound, HT AVR suitable for indoor outdoor installation, copper wound HT AVR system is a revolutionary landmark in the industry when it comes to voltage regulation and stabilization. Even after the installation of standard distribution transformer the problem of low high voltage on the LT loss of a plant.
Furnace Transformer are built in delta star connection with neutral as floating & electrostatic shielding is used to protect the furnace from any kind of Earth Fault Tripping.
Furnace Transformer are built in delta star connection with neutral as floating & electrostatic shielding is used to protect the furnace from any kind of Earth Fault Tripping.
Technical Specifications
50 kVA to 5000 kVA, 11 kV & 33 kV Class suitable for Indoor applications with off circuit tap links, off circuit tap switch, on load tap changer (Indigenous & Imported).
Technical Specifications
50 kVA to 5000 kVA, 11 kV & 33 kV Class suitable for Indoor applications with off circuit tap links, off circuit tap switch, on load tap changer (Indigenous & Imported).
DISTRIBUTION TRANSFORMER POWER TRANSFORMER
6.6 KV, 11 KV, 25 KV & 33 KV
Upto 30 MVA
Lowest Capacity is 5 KVA
APPLICABLE STANDARDS
IS, IEC, ANSI, JIS, BS, DIN, ETC.
DISTRIBUTION TRANSFORMER POWER TRANSFORMER
6.6 KV, 11 KV, 25 KV & 33 KV
Upto 30 MVA
Lowest Capacity is 5 KVA
APPLICABLE STANDARDS
IS, IEC, ANSI, JIS, BS, DIN, ETC.
An automatic voltage regulator, by regulating the level of voltage in an alternating current (AC) system to a narrower range of output, protects parts of the system that might be damaged by surges or drops in power.
An automatic voltage regulator, by regulating the level of voltage in an alternating current (AC) system to a narrower range of output, protects parts of the system that might be damaged by surges or drops in power.
Advantages:
High Saturation Flux Density (1.56 T).
Low Profile - enables weight and volume reductions of up to 50%.
Low Temperature Rise - enabling smaller compact designs.
Low loss - resulting from extremely thin Iron Based Amorphous ribbon (25 um).
Advantages:
High Saturation Flux Density (1.56 T).
Low Profile - enables weight and volume reductions of up to 50%.
Low Temperature Rise - enabling smaller compact designs.
Low loss - resulting from extremely thin Iron Based Amorphous ribbon (25 um).
Secondary Business TypeManufacturer / Wholesale Suppliers
Year of Establishment1982
No. of Employees251 - 500
Annual TurnoverRs. 50 to 100 Crore Approx.
Opening Hours
SUN : Closed
MON : 9:30 AM - 6:30 PM
TUE : 9:30 AM - 6:30 PM
WED : 9:30 AM - 6:30 PM
THU : 9:30 AM - 6:30 PM
FRI : 9:30 AM - 6:30 PM
SAT : 9:30 AM - 6:30 PM
Servomax India Ltd. is Retailer of Inverter, Isolation Transformer, Ups, Distribution Transformer, Industrial Transformers, Dry Type Transformer, H.T. Transformer, H.T. Automatic Voltage Stabilizer, Furnace Transformers, Variable Transformers from Hyderabad, Telangana.