Isolation Transformers Dealers in Ghatkopar, Mumbai

(12 products available)
  • Double Wound Transformer

    Double Wound Transformer

    Get Price Quote

    • Phase: Single & Three Phase
    • Cooling Type: Dry Type/Air Cooled
    • No. of Winding: Double Winding
    • Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
    • Input Voltage: 400- 450 V
    • Insulating Fluid: Mineral Oil

    We are offering transformer. Double wound, step-down transformer made from high quality annameled dpc copper wire of circular & square cross selection & having crgo lamination as core. Transformer core is cylindrically designed to overcome losses and achieve maximum efficiency high packing fraction enables compact transformer design & reduces heating in high load condition ballast choke is single wound inductor made of crno lamination &anameled copper wire set to perfection to controll current & voltage drop at perticular current load. Setting only possible at factory.

    more..
  • K Rated Isolation Transformer

    K Rated Isolation Transformer

    Get Price Quote

    Neel industrial systems pvt. Ltd. Is a supplier of k rated isolation transformer in mumbai. K-factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 50hz.

    more..
  • Best Deals from Isolation Transformer

  • CONTROL TRANSFORMERS

    CONTROL TRANSFORMERS

    1,900 - 2,000 Per Pack

    • Type: Control Transformers
    • Color: Green, Grey, Light Green, Sky Blue
    • Application: Equipments Controlling
    • Condition: New, Used
    • Automatic Grade: Automatic, Fully Automatic
    • Cooling System: Air Cooled, Oil Cooled
    • Warrenty: 1yr, 2yrs
    more..
  • Electric Two Phase Transformer

    Electric Two Phase Transformer

    Get Price Quote

    • Power: Electric
    • Phase: Two phase
    • Cooling Type: Oil Cooled
    • Material: Stainless Steel
    • Usage: Industrial
    • Single Coil Current: 1-150 amp
    • Ganged Coil Current: 150 amp
    • Minimum Order Quantity: 1 Piece
    more..
  • Isolation Transformer

    Isolation Transformer

    Get Price Quote

    K-factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 50Hz. K-Factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 50Hz. It is used to evaluate transformers for nonlinear loads. Transformers with a rated K-factor of 4, 7, 13, 20 and 30 are available. The ANSIIEEEE C57.110 has derived a system of weighing how much harmonic load currents a transformer can handle without exceeding its maximum temperature rise level. A K factor of 1 indicates no harmonics, while a K factor of 50 is the harshest harmonic environment possible. Typically a K Factor of 13 is sufficient for most applications. K factor must be determined to calculate the right size transformer that is needed. Applications Data Centres, Call Centres, IPO Induction HeatersInverters UPS, VFD’S & Drives HID Lightings HospitalsMedical Centres, Research Labs Corporate, Banking and Financial Institutions

    more..
  • Ultra Isolation Transformer

    Get Price Quote

    We are offering a wide range of ultra isolation transformer, which protect the Computers, CNC Machines and Telecommunications equipment from damage due to electrical noise, spikes etc. Also used where different ground potential exists or the ground of the equipment cannot be earthed.

    more..
  • Ultra Isolation Transformer

    Get Price Quote

    As an Ultra Isolation Transformer, Unity’s Tranquil is the most powerful solution to help eliminate all types of noise, particularly Common Mode Noise, Spikes, Surges and Transient Noise, which act as silent killers inside factories and commercial parks alike.

    more..
  • control circuit transformer

    control circuit transformer

    Get Price Quote

    • Min. Order Quantity: ,

    We bring forth Control Circuit Transformer with basically electric components fitted on the Circuit boards which are then fitted in the Junction boxes and are used in the monitoring of the current passed on to the Oil pipelines, Tank farms and Oil wells to avoid disruption of the flow of the Oil and Gas. A Control Circuit Transformer is a device designed to provide a reduced control voltage for energizing the coils of electromagnetic devices such as motor starters, contactors, relays, & electronic circuits. These devices make up the majority of the loads supplied by the Control Circuit Transformer. Control Circuit Transformer is also referred to as Industrial Control Transformers, Machine Tool Transformers, and Control Power Transformers, Inrush Volt-Ampere & Sealed Volt-Ampere considerations. The proper size, or the VA rating, of the Control Circuit Transformer is important. It will be a determining factor in the life of the transformer, which ultimately will reflect on the proper operation of control devices that it supplies.  Methods of Selecting The methods of selecting transformer VA ratings addressed in this technical paper are applicable to 50-3000 VA. Control Circuit Transformer. The transformers used in this application fall into the dry type insulation category. Typical primary voltages are 600, 480, 240, and 110. Transformers can also be manufactured with special primary & secondary voltage combinations. There are two VA values to be considered when selecting a transformer. Energizing electromagnetic components creates a large momentary surge current, commonly referred to as inrush VA. This is the first VA value to be considered. The inrush VA will last approximately 5-20 milliseconds and can have a value as high as ten times the transformer's nameplate rating. Thus, the inrush VA will be high in value and short duration. A properly selected control circuit transformer is designed to handle the momentary inrush VA and at the same time maintain a secondary voltage within a set range. The second value to be considered is the sealed VA, the amount of volt-amperes required to maintain the energized state of an electromagnetic device. This VA requirement will be 5 to 10 times less than the inrush VA.Specifications Range : 1mA to 20 A Taps : As per client spec. ( We are also provided PCB with connector) Shielding Lamination : CRGO or CRNO Input : 110/230/440V AC

    more..
  • Isolation Transformers

    Get Price Quote

    GI Octagonal Poles, air break isolator, GI Poles, HT Isolator, Oil Test Set

    more..
  • CONTROL TRANSFORMERS

    Get Price Quote

    Battery Chargers, electronic rectifiers

    more..
  • CONTROL TRANSFORMERS

    Get Price Quote

    dc filter chokes, Transformers

    more..
  • Instrument Transformers

    Get Price Quote

    Instrument Transformers, Panel Accessories, Earthing Protection Equipments

    more..