Neutral Grounding Resistors Dealers in Mumbai

(3 products available)
  • Neutral Grounding Reactors

    Neutral Grounding Reactors

    Get Price Quote

    Neutral Grounding Reactors (NGRs) are used to control single line to ground faults only. NGR are particularly used at transmission voltage levels, when autotransformers with a delta tertiary are employed. Neutral Grounding Reactors (NGRs), normally installed between the transformer or generator neutral and ground, are effective in controlling single line to ground faults since, in general, the system short circuit impedance is largely reactive. NGRs reduce short circuit stresses on station transformers the most prevalent type of fault in an electrical system. We have supplied 145KV neutral grounding reactors for 6 X 660MW at Lalitpur Thermal Power Projects through BIDCO & L&T for 220 KV, 765 KV switchyard installation. We have recently installed 145 KV Dry Type neutral grounding reactors at a power grid substation
    ...more
  • Neutral Grounding Reactors

    Neutral Grounding Reactors

    Get Price Quote

    Neutral Grounding Reactors (NGRs) are used to control single line to ground faults only. NGR are particularly used at transmission voltage levels, when autotransformers with a delta tertiary are employed. Neutral Grounding Reactors (NGRs), normally installed between the transformer or generator neutral and ground, are effective in controlling single line to ground faults since, in general, the system short circuit impedance is largely reactive. NGRs reduce short circuit stresses on station transformers the most prevalent type of fault in an electrical system.
    ...more
  • Neutral Grounding Resistors

    Neutral Grounding Resistors

    25,000 - 500,000 / Piece

    • Brand NamePIONEER ELECTRICAL WORKS,PIONEER ELECTRICAL WORKS
    • MaterialStainless Steel
    • FinishingPolished
    • ShapeRactangle
    • Termination StyleCopper Flat
    • Max. Power DissipationDepends on rating/requirement
    • UsageTransformer/DG
    • CertificationIEEE32
    • Country of Originup to 33kV
    • Operating Temperature250-750
    • Packaging TypeWooden Box
    • SpecialitiesSimple To Use, Good Quality, Fine Finishing
    • IP GradeIP 40
    • Number Of FlowerVariable Resistors
    • Frequency50/60hZ
    • PhaseSingle Phase
    • Total Carbohydrate1 Year
    • Country of OriginIndia
    • Degree of ProtectionIP42
    • Max. Current Rating3000A
    • The Neutral  Grounding Resistors are generally employed in the LV and MV distribution networks to protect power transformers and generators from damaging currents in the event of earth fault. This protection system represents the best choice in terms of fast response to localize the fault and consequently to reduce and prevent the overheating and mechanical stress on the conductors.   Alternative protection systems like insulated neutral or direct earthing neutral  have several and significant disadvantages such as dangerous transient over-voltages and high difficulties to localize the ground fault in the insulated systems or damaging fault currents with possible arc blast  in the earthing neutral  systems.   By inserting the Neutral Grounding Resistors with appropriate characteristics between the neutral point of the transformer and the ground it is possible to limit the ground fault current for a short time to allow a quick localization of the fault but, at the same time, it does not damage the equipment.  