DIGITAL AUTOMATIC TAPBULK DENSITY TEST APPARATUS:Incorporated with Advanced Microcontroller.Equipped with Built-in Validation Facility.Auto Tap repeat facility till the test is completed.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.Also available as pr ASTM Standards.
DIGITAL AUTOMATIC TAPBULK DENSITY TEST APPARATUS:Incorporated with Advanced Microcontroller.Equipped with Built-in Validation Facility.Auto Tap repeat facility till the test is completed.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.Also available as pr ASTM Standards.
Measures thickness, width, diameter, and hardness accurately,Measuring Units: mm, Kg, kp and N,Local tactile keypad and QWERTY keyboard for data entry.Equipped with microcontroller based circuitry, specially designed to measure Hardness, Diameter and Thickness of the tablets.
Measures thickness, width, diameter, and hardness accurately,Measuring Units: mm, Kg, kp and N,Local tactile keypad and QWERTY keyboard for data entry.Equipped with microcontroller based circuitry, specially designed to measure Hardness, Diameter and Thickness of the tablets.
Advanced microprocessor-based circuitry.Designed with a 10° tilt feature, used when the shape or size causes irregular tumbling.The two acrylic drums having a slot positioned to automatically discharge the tablets.Provides connectivity to balance via RS 232 interface to weigh the tablets.Interlocking mechanism to ensure correct drum position, Advanced micro-controller circuitry and user friendly software.The drums have a slot positioned to automatically discharge the tablets into the ma gnetic trays, at the end of the test without dismantling the drum assembly.
Advanced microprocessor-based circuitry.Designed with a 10° tilt feature, used when the shape or size causes irregular tumbling.The two acrylic drums having a slot positioned to automatically discharge the tablets.Provides connectivity to balance via RS 232 interface to weigh the tablets.Interlocking mechanism to ensure correct drum position, Advanced micro-controller circuitry and user friendly software.The drums have a slot positioned to automatically discharge the tablets into the ma gnetic trays, at the end of the test without dismantling the drum assembly.
14 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.14 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Motorized sensor tray to measure individual vessel temperature, can be programmed to move as per set time.Equipped with very reliable maintenance free stepper motor drive for stirrers.
14 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.14 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Motorized sensor tray to measure individual vessel temperature, can be programmed to move as per set time.Equipped with very reliable maintenance free stepper motor drive for stirrers.
Temperature32.0 °C to 40.0 °C (Default setting 37.0 °C).
Automatic rotation through 180 Degrees.
Selectable cycling time for 1 minute or as desired.Programmable testing time for 1 min. to 10 hours.Digital display of elapsed testing time.Built-in circulation pump, to maintain the Temperature at 37.0 °C.Temperature settable between 32.0 °C to 40.0 °C (Default setting 37.0 °C).Simultaneous test of 3 samples possible.
Automatic rotation through 180 Degrees.
Selectable cycling time for 1 minute or as desired.Programmable testing time for 1 min. to 10 hours.Digital display of elapsed testing time.Built-in circulation pump, to maintain the Temperature at 37.0 °C.Temperature settable between 32.0 °C to 40.0 °C (Default setting 37.0 °C).Simultaneous test of 3 samples possible.
Suitable for AqueousNon-Aqueous and Red-Ox titrations.Titrant can be changed within no time.Eliminates the need of interchangeable burette for different titrants.PS-2 Keyboard (QWERTY Keyboard) Interface for easy alphanumeric data entry.Login Screen to login onto software.The system tracks the print & re-prints with the audit trail.Results are authenticated by Operator with Date and Time Stamped.
Suitable for AqueousNon-Aqueous and Red-Ox titrations.Titrant can be changed within no time.Eliminates the need of interchangeable burette for different titrants.PS-2 Keyboard (QWERTY Keyboard) Interface for easy alphanumeric data entry.Login Screen to login onto software.The system tracks the print & re-prints with the audit trail.Results are authenticated by Operator with Date and Time Stamped.
Designed to measure and record the melting point of 3 samples simultaneously,Graphical LCD displaying the real time Time vs Temperature graph,Attached camera displays live, high-resolution images of each sample.
Designed to measure and record the melting point of 3 samples simultaneously,Graphical LCD displaying the real time Time vs Temperature graph,Attached camera displays live, high-resolution images of each sample.
User accounts facility available,System security by password protection,Built in RTC for time and date display and test report legitimacy.PS-2 computer key board for data entry.
User accounts facility available,System security by password protection,Built in RTC for time and date display and test report legitimacy.PS-2 computer key board for data entry.
Karl Fischer Titrator is used for Accurate Moisture Estimation in various samples. The Karl Fischer method is used for many substances as a reference method. It is a chemical analysis procedure which is based on the oxidation of sulfur dioxide by iodine in alcoholic solution. The titration can be performed Volumetrically or Coulometrically.
Karl Fischer Titrator is used for Accurate Moisture Estimation in various samples. The Karl Fischer method is used for many substances as a reference method. It is a chemical analysis procedure which is based on the oxidation of sulfur dioxide by iodine in alcoholic solution. The titration can be performed Volumetrically or Coulometrically.
DIGITAL TABLET FRIABILITY TEST APPARATUS:Designed with a 10° tilt feature.Supports standard drum and abrasion drum.Incorporated with powerful sturdy motor.Single drum model available.
DIGITAL TABLET FRIABILITY TEST APPARATUS:Designed with a 10° tilt feature.Supports standard drum and abrasion drum.Incorporated with powerful sturdy motor.Single drum model available.
8 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.8 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Molded Water Bath with non-corrosive Tank plate.Bank of 12 operator names with individual password.Facility to enter Company name on the test report.Wake-up mode to turn on the heater on predetermined time intervals.
8 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.8 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Molded Water Bath with non-corrosive Tank plate.Bank of 12 operator names with individual password.Facility to enter Company name on the test report.Wake-up mode to turn on the heater on predetermined time intervals.
14 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.14 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Motorized sensor tray to measure individual vessel temperature, can be programmed to move as per set time.Equipped with very reliable maintenance free stepper motor drive for stirrers.Tablet dropping system.Sampling tray with 6 probes can be programmed to move as per set time.
14 Nos. Easy to attach and detach `Press Fit’ wobble free Stirrer shafts with removable Paddle basket assembly.14 Nos. Unbreakable clear MOULDED Dissolution Vessels or Glass Vessels.Motorized sensor tray to measure individual vessel temperature, can be programmed to move as per set time.Equipped with very reliable maintenance free stepper motor drive for stirrers.Tablet dropping system.Sampling tray with 6 probes can be programmed to move as per set time.
DisplayInformative 240 x 64, blue graphic LCD display
‘PARKING’ facility: Enables stationary positioning of individual baskets above test media before and after test independently.‘PAUSE' facility: This facility permits to check disintegration state of the tablets intermittently and continue test without disturbing test parameters.Power failure indication program is incorporated.
‘PARKING’ facility: Enables stationary positioning of individual baskets above test media before and after test independently.‘PAUSE' facility: This facility permits to check disintegration state of the tablets intermittently and continue test without disturbing test parameters.Power failure indication program is incorporated.
Incorporated with Advanced Microcontroller.Equipped with Built-in Validation Facility.Test method storage facility for 24 test methods.Auto Tap repeat facility till the test is completed.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.Compliant with USP – I and USP – II methods.
Incorporated with Advanced Microcontroller.Equipped with Built-in Validation Facility.Test method storage facility for 24 test methods.Auto Tap repeat facility till the test is completed.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.Compliant with USP – I and USP – II methods.
Incorporated with Advanced Microcontroller,Equipped with Built-in Validation Facility,Test method storage facility for 24 test methods.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.
Simultaneous rotating and tapping of the cylinders.
Incorporated with Advanced Microcontroller,Equipped with Built-in Validation Facility,Test method storage facility for 24 test methods.Calculates Bulk Density, Tapped Density, Compressibility Index and Hausner Ratio.
Simultaneous rotating and tapping of the cylinders.
Melting Point of three samples can be determined at the same time.
Boiling Point can be determined for one sample.Graphical representation with Time VS. Temperature.8 Operator names can be stored with INDIVIDUAL PASSWORD.Equipped with camera and color monitor to observe Melting Point with ease.Three tier operator hierarchies will be provided for security and instrument access.User has to enter correct user ID and password to access their authorized jobs.
Melting Point of three samples can be determined at the same time.
Boiling Point can be determined for one sample.Graphical representation with Time VS. Temperature.8 Operator names can be stored with INDIVIDUAL PASSWORD.Equipped with camera and color monitor to observe Melting Point with ease.Three tier operator hierarchies will be provided for security and instrument access.User has to enter correct user ID and password to access their authorized jobs.
Incorporated with maintenance free Dispenser.No Refilling is necessary after every titration.Several titrations can be carried out uninterruptedly.Average factor calculation facility.Results are Automatically Calculated in Percentage, PPM and mg of H2O.Inbuilt volume validation facility.Equipped with inbuilt volume validation facility.RS 232 Interface for PC to download the data.Three User Level based functionality: Admin, Manager and Operator.
Incorporated with maintenance free Dispenser.No Refilling is necessary after every titration.Several titrations can be carried out uninterruptedly.Average factor calculation facility.Results are Automatically Calculated in Percentage, PPM and mg of H2O.Inbuilt volume validation facility.Equipped with inbuilt volume validation facility.RS 232 Interface for PC to download the data.Three User Level based functionality: Admin, Manager and Operator.
Water Contents is estimated by measuring amount of electrolysis current to produce required Iodine. This is an absolute technique that does not require Calibration of Reagent.Automatic Drift Compensation.Range: 1 PPM to 100 % with appropriate sample quantity.Results are Automatically Calculated in Percentage, PPM and mg of H2O.Error Messages informs problem about Electrode.
Water Contents is estimated by measuring amount of electrolysis current to produce required Iodine. This is an absolute technique that does not require Calibration of Reagent.Automatic Drift Compensation.Range: 1 PPM to 100 % with appropriate sample quantity.Results are Automatically Calculated in Percentage, PPM and mg of H2O.Error Messages informs problem about Electrode.