Fieldbus Components Dealers

(31 products available)
  • Premium
    750 347 Fieldbus Coupler CANopen

    750 347 Fieldbus Coupler CANopen

    36,430 / Piece

    • MOQ1 Piece
    • Brand NameWago
    • ApplicationIndustrial Use
    • Country of OriginIndia
    • Country of Origin240 V
    • MountingDin Rail
    • Packaging TypeBox
    • 750-347 Fieldbus Coupler (CANopen) from WAGO connects WAGO-I/O-SYSTEM 750 modules to a CANopen network, enabling seamless data exchange. It supports efficient communication, diagnostics, and easy integration into industrial automation systems.
    ...more
    www
  • Premium
    Wireless Io Extender

    Wireless Io Extender

    34,000 / piece

    • MOQ1 piece
    • Frequency50Hz
    • Country of OriginIndia
    • Input Supply Voltage85-265 VAC / 24VDC (Factory Settable)
    • Operating Temperature-20°C to 85°C
    • Frequency RangeISM Band 433-434 MHz
    • AntennaRubber Duck Antenna
    • Mounting TypeWall / Din Rail
    • SafetyRF COM Loss Output , Auto Channel Switching, DC Reverse Polarity
    • Packaging TypeBox
    • UsageExtending Wireless Network Coverage
    • Power SourceElectric Outlet
    ...more
    www
  • Remote Io Modules

    Remote Io Modules

    15,000 / Piece

    • Brand NameSpan
    • Operating Temperature-10 to 70 deg C
    • Model Name/NumberADAM-6251
    • Supply Frequency0.1 to 3 kHz
    • Storage Temperature-20 to 80 deg C
    • Operating Humidity20 to 95 % RH
    • Storage Humidity0 to 95 % RH
    • Dimensions70 x 122 x 27 mm
    • Power Input10 - 30 V DC
    ...more
  • Digital Input Module

    Digital Input Module

    Get Price Quote

    • Brand NameTROPOSPHAIRA
    • Power12-24 VAC DC
    • Frequency50Hz
    • Country of Origin12024 VDC AC
    • Country of OriginMade in India
    • Current0.1 A
    • Model Name/NumberTP-16DI
    • No. Of Channels16
    • DimensionsL110XH110XB50MM
    • Instrument TypeDIGITAL INPUT MODULE
    • Network Speed9600 - 115200 bps
    • Number Of Ports/Pins1
    • CommunicationMODBUS
    • Type Of MountingDIN Rail
    • Ambient Temperature0 - 60
    • IO Module with 16 Port DI with Dual detection ( voltage detection 3 - 40 V DC or potential free detection with on board 12 V DC ref) and Modbus RS485 interface. SW for Slave ID and Baud rate selection. Closed DIN rail mountable enclosure.
    ...more
  • Digital Io Module +2

    Digital Io Module

    10,500 / Piece

    • MOQ10 Piece
    • Country of OriginIndia
    • Frequency50 Hz
    • Number Of Ports/Pins4 Pins
    • MaterialABS
    • Dimensions115mm x 90mm x 40mm
    • Input voltage24 V DC
    • Number of Channel8
    • Resolution16 Bit
    • PhaseSingle Phase
    • Humidity95%
    • Operating Temperature-40 to 70 Degree C
    • Isolation3000 Vrms
    ...more
  • TEMPERATURE CONTROLLER WITH 20A RELAY & ALARM OUTPUT SZ-7558-P SZ-7568-P

    TEMPERATURE CONTROLLER WITH 20A RELAY & ALARM OUTPUT SZ-7558-P SZ-7568-P

    1,120 - 2,240 / piece

    • MOQ1 Piece
    • Brand NameSub Zero
    • Driven TypeElectric
    • Current TypeAC, DC
    • ConditionNew
    • ApplicationFor Panel A/C & Application Requiring Alarms
    • Size75 X 34.5mm
    • FeatureAuto Controller, Switch Off Compressor At Setpoint. Manual / Auto Restart Options. Alarm Output For High / Low Temp
    • Country of Origin230V
    • Display TypeDigital
    • Mounting TypePanel Mount, Panel Cutout : 71 X 29mm
    • Number Of FlowerTemperature Controller
    • Temperature Range0.0°C To +50.0°C (for SZ-7558-P) -40.0°C To +50.0°C (for SZ-7568-P)
    • Country of OriginIndia
    • Power supply options230Vac Standard
    • Display 7 Segment LED Display, 3 x 14.2mm (0.56") Probe Inputs NTC Relay Outputs Compressor : 20A (Inductive)Alarm : 5A Power Supply 230Vac Standard Temperature Range 0.0°C to +50.0°C (for SZ-7558-P)-40.0°C to +50.0°C (for SZ-7568-P) Size 75 x 34.5mm Mounting Type Panel Mount, Panel Cutout : 71 x 29mm Application For panel A/C & application requiring alarms
    ...more
  • Profibus Cable

    Profibus Cable

    52 / Meter

    • Conductor MaterialCopper
    • Country of Origin300 to 750V
    • Cable Size12 to 20 AWG
    • Type of CableInsulated
    • Insulation MaterialPVC
    • Rated Temperature60 to 105 deg C
    • Nominal Cross Section0.50 to 120 mm2
    ...more
  • Io Modules

    Io Modules

    Get Price Quote

    IO Modules With the CANio 250500 and the ETCio 100, HMS offers three modules enabling quick and easy connection of analog and digital input and output signals to CAN, CANopen and EtherCAT systems – whether in experimental setups, test benches or vehicles. To adapt the IO modules to your requirements, HMS also offers a special Application Development Kit for the CANio 250500.
    ...more
  • Bus Bar Connector

    Bus Bar Connector

    Get Price Quote

    • Brand NameWoehner
    • Tightening Torque20Nm
    • Permitted Busbar Displacement5mm
    • Permitted Spacing Between Systems50 - 60 Mm
    • Permitted Voltage1000-1500V
    • Peak Withstand Current56.3 kA
    • Size95 x 37 x 25
    • Current rating520A - 2500A
    • Model Number01141
    • Voltage250V
    ...more
  • FIOD Field Digital I/O Modules

    FIOD Field Digital I/O Modules

    Get Price Quote

    • Rated Input Voltage24 VDC (Max is 28VDC)
    • Input Impedance5.6 k
    • Rated Input Current4mA
    • Logic ‘0’ Voltage0 to 5V
    • Maximum Load current500 mA
    • Power Supply+24 V DC ± 10%
    • Communication Port:2 Wire RS485
    • Digital Inputs : Logic ‘1’ Voltage12 to 28V
    • Digital Outputs (Transistor) Voltage drop at ON0.4V or less 
    • Digital Outputs (Relay) Relay Rating230V AC, 2 Amp. (Max.)
    • Temperature: Operating Storage0o to 60o C -20o to 80o C
    • Humidity10% to 90% (Non condensing)
    • MountingDIN rail mounting
    • Dimensions (DIN rail)100W X 70H X 35D mm
    • Immunity to ESDas per IEC61000-4-2
    • Immunity to Fast Transientsas per IEC61000-4-4
    • Immunity to Radiated electromagnetic fieldas per IEC61000-4-3
    • Immunity to Conducted disturbancesas per IEC61000-4-6
    • Surgeas per IEC61000-4-5
    • Radiated emissionas per EN61000-6-4
    • Isolation1.5KV isolation between communication ports, I/O and power supply section.
    •  Features Low cost compact Digital I/O modules with DIN rail mounting 2 wire RS 485 port provided on pluggable terminal block User definable Address, Baud rate and Parity through DIP Switch High Speed Modbus RTU (Slave) communication LED indication for each Input and Output , COM Port and Power ON  No configuration software required Relay and Transistor outputs available CE marked with optional UL certification Basic FIOD Operations FunctionThe FIOD series products add digital capability to PLC / SCADA. Models are available that offer upto 16 digital inputs and upto 16 digital outputs. The digital inputs and outputs are isolated from the host device. FIOD has one RS 485 (2 Wire) communication port to connect to host device. Communication settings like baud rate, parity and station ID can be set by DIP Switch.Communication with HostFIOD module supports Modbus RTU (Slave) Protocol. The communication can be done with Host through 2 wire RS 485 Network.In case of communication failure with Host, all the outputs are switched OFF.Modbus Registers MappingThere are 128 Modbus registers supported in FIOD. Out of which, 64 are input registers (1 to 64) which are mapped to input coils 1 to 1024. FIOD has 64 output registers (65 to 128) which are mapped to output coils 1025 to 2048. First 16 coils from 1 to 16 are assigned for FIOD inputs (1 to 16). Coils from 1025 to 1040 are assigned for FIOD outputs (1 to 16). Modbus Mapping of Registers and Coils are mentioned below :Sr.     Register          Range             Modbus                Modbus No.    /Coil                                       Mapping               Tag Length 1.     Input Register      1-64                40001-40064         2 -bytes2.     Output Register    65-128             40065-40128         2 -bytes3.     Input Coil            1-1024             00001-01024         1-bit4.     Output Coil          1025-2048        01025-02048         1-bit
    ...more
  • Passive Interface Modules

    Passive Interface Modules

    Get Price Quote

    Passive Interface Modules are used to convert the conventional wiring into Modular Wiring. It consists of FRC Male connector at one side and screw type/screw-less terminals at the other side.  
  • Extension Unit

    Extension Unit

    Get Price Quote

    • Number Of FlowerK2HNV-XS
    • Safety Contacts3
    • Safety Leveldepending on main relay
    • Power Supply Voltage24 V AC/DC
  • EtherCAT

    EtherCAT

    Get Price Quote

    The EtherCAT that we offer is propagated by the EtherCAT Technology Group (ETG). Our EtherCAT helps in manipulating the data while it passes through the devices. Our EtherCAT is demanded in the market for its high performance. Attributes : Ring systemUses sunframe protocolTwo physical versions- E-Bus and EthernetEthernet version for Lenze controllers Communication Module Types : Communication module (MXI) Used In : L-force Inverter Drives 8400L-force Servo Drives 9400Communication module (AIF) Used In : Servo Umrichter 9300Servosystem ECSFrequenzumrichter 8200 vector
    ...more
  • 2170220 Profibus Cable

    2170220 Profibus Cable

    Get Price Quote

    • Brand NameLapp
    • PROFIBUS-DP/FMS/FIP, 1 Pair, Copper Braided and Foil Screened, Polyvinyl chloride (PVC) outer sheath colour Violet for Bus Systems, fixed installation, indoor use, conductor size of 0.64 mm ø, 250 V (Not for power application), 8mm OD, Flame Retardant to IEC 60332-1-2, Approvals: Fire protection, ULC.   Product Description Application Range For fixed installationMaximum electromagnetic screening Dry or damp rooms Item nos. 2170233, 2170333, 2170820, 2170824, 2170826 are all UV-resistant   Norm References / Approvals In accordance with DIN 19245 and EN 50170, e.g. for SIEMENS SIMATIC NET, also suitable for FIP (Factory Instrumentation Protocol) See below for UL certification type   Product Make-Up FC: Fast Connect cable design 7-W: 7-wire, e.g. for applications where vibrations occur PE: polyethylene outer sheath, black P: PolyurethaneH: Halogen-free  COMBI: Data transmission andpower supply in one cable   Product Features These bus cables can be used for PROFIBUS-DP as well as for PROFIBUS-FMS and FIP Based on the bit rates listed, in accordance with PNO specifications the following maximum cable lengths for a bus segment apply(cable type A, PROFIBUS-DP):93.75 kbit/s = 1200 m187.5 kbit/s = 1000 m500 kbit/s = 400 m1.5 Mbit/s = 200 m12.0 Mbit/s = 100 m   Technical Data Minimum Bending Radius Fixed installation: see data sheet   Test Voltage Core/core: 1500 V rms   Peak Operating Voltage (not for power applications) 250 V   Classification ETIM 5 ETIM 5.0 Class-ID: EC000830 ETIM 5.0 Class-Description: Data cable   Classification ETIM 6 ETIM 6.0 Class-ID: EC000830 ETIM 6.0 Class-Description: Data cable
    ...more
  • 10 Outputs Feeders Batch Controller with Tank System

    10 Outputs Feeders Batch Controller with Tank System

    45,000 - 55,000 / Piece

    • MOQ1 Piece
    • Country of OriginIndia
    • CertificationCE Certified, ISO 9001:2008
    • ApplicationProcess Automation
    • FeatureRust Proof
    • Country of Origin110V
    • Power1-3kw
    • Power SourceElectric
    • Total Carbohydrate1year
    • Size4 inch
    • Product7 type
    • Brand NameSGEI
    • Manufacturer SeriesTypes of Feeders 10 Output Relay Type Batch Controllers
    • Output TypeDigital
    • Display TypeLED
    • Usage/ApplicationAutomation
    ...more
  • Analog IO Module

    Analog IO Module

    Get Price Quote

    analog io modules are devices that are Input Output to a SCADA. Inputs are Temperature, Pressure, Flow rate, Humidity, Level etc called as Analog Inputs. Inputs from Flow switches, level switches, Pressure switches, Proximity switches, Limit switches, auxiliary contact of contactor etc are called Digital Inputs.
    ...more
  • UNIVERSAL ANALYTICAL CONTROLLER +3

    UNIVERSAL ANALYTICAL CONTROLLER

    Get Price Quote

    • MOQ1 Piece(s)
    • Number Of FlowerAnalytical Instruments
    • Brand NameELECTRONET
    • Display TypeLCD Graphical (128x64)
    • Power Supply1) 24 V DC 2) 85 to 265 V AC,50Hz
    • Accuracy1) pH, ± 0.02pH of F. S. 2) ORP, ± 2mV of F. S. 3) DO, +/-0.25% of FS 4) Conductivity, ± 0.25% of F.
    • Country of OriginIndia
    • Model NumberUAC-100
    • UAC-100 is dual input analyzer with single or dual sensor input. This analyzer supports wide range of measurement choices in industrial applications. It can accept pH / Conductivity / ORP / DO sensor input in any combination.
    ...more
  • Interface Module

    Interface Module

    20,000 / Piece

    • MOQ1 Piece
    • Usage/ApplicationIndustrial
    • Network TypePLC
    • Brand NameReputed
    • Model NumberUL08AO-RED-D25-SRC
    • Input Output Control MethodInput : 4-20mA & Output : 4-20mA. 24VDC, 3 way Isolation
    • No. of Poles4 poles
    • Mounting TypeHorizontal
    ...more
  • PROFIBUS Converter

    PROFIBUS Converter

    Get Price Quote

    • Brand NameElgo
    • Dimensions160 x 55 x 40 mm (LxWxH)
    • Operating Voltage19-27V DC
    • Power Inputmax. 0,2 A
    • Storage Temperature- 40... + 85 Degree C
    • Work temperature0... + 60 Degree C
    • Protection classIP50 standard,IP67 optional
    ...more
  • Digital Input Output Module

    Digital Input Output Module

    Get Price Quote

    Digital Input Digital Output Module Falcon DIDO24, Digital Input/output module with RS485 connectivity which is best suitable for SCADA. Digital Input/output module can also be used as slave module with PLC. Digital Input/output module use MODBUS RTU protocol for serial communication. RS485 serial port is provided to make the modules suitable for multi dropping application.Digital Inputs are optically isolated inputs and accepts potential free contact signals. Digital Input/output module can be used for sensing level switches,proximity switches, door switches, alarm/trip conditions in panel, pump/motor status, equipment status etc. Digital Outputs are optically isolated open collector outputs to drive external relay module. These outputs can be used to perform supervisory control actions like giving alarms, operating valves, switching ON/OFF pumps/motors etc.
    ...more
  • Profibus Cable

    Profibus Cable

    Get Price Quote

    Industrial grade profibus cable mainly used for profibus network. Maximum Speed : 12 mbps 1 Pair 2 Core Available in PVC and PUR.
  • Profibus Communications Module

    Profibus Communications Module

    Get Price Quote

    • Number Of FlowerProfibus Communications Module
    • We are the leading supplier of this products.
  • Fieldbus Components

    Fieldbus Components

    Get Price Quote

    Fieldbus Components, Servo Drives, Stepper Drives, Linear Servo Motor
  • I/O-Module

    I/O-Module

    Get Price Quote

    I / O-Modul
  • Interface Modules

    Interface Modules

    Get Price Quote

    Interface Module
  • Profibus Cable

    Profibus Cable

    Get Price Quote

    Profibus Cable, Profinet Cable, Instrument Cables, Signal Cabl
  • Interface Module

    Interface Module

    Get Price Quote

    Interface Module, Andon Displays, RPM Indicator, Display Pane
  • Controller with USB Input

    Controller with USB Input

    Get Price Quote

    Controller with USB Input, LAN Adapters, Industrial PC, USB Stick
  • Interface Module

    Interface Module

    Get Price Quote

    Interface Module, Industrial Microwave Line Status Display, Andon Display
  • Analog IO Module

    Analog IO Module

    Get Price Quote

    Analog IO Module, Metering Panels, Sensor Controller, Servo Control Syste
Filter by Locality
top