Test Chamber Dealers in Patel Nagar, Delhi

(6 products available)
  • COLD BEND TEST CHAMBER

    COLD BEND TEST CHAMBER

    Get Price Quote

    The apparatus will be able to bend the sample backward and forward in a direction perpendicular to the plane of the conductors, the two extreme positions making an angle of 90° on both sides of the vertical. Rate of flexing will be 60 per minute. A flexing is a movement through 180°. A weight having mass of 0.5 kg will be provided with suitable grips for hanging to the sample. The apparatus will have a provision for fixing the sample of tinsel cord (Flat) in the apparatus. A 6 Digit reset able type counter with battery back-up (rechargeable) for retaining the information in case of power failure up to 72 hours will be provided for counting each flexing cycle. The standard motors used in the apparatus. The apparatus will be able to operate on single phase 230 V, 50 Hz. AC supply. Technical Specifications SIZE:                                                        As per requirement. TEMPERATURE RANGE:                    (-) 40 Deg. C. TEMPERATURE UNIFORMITY:          +/- 1 Deg. C. TEMPERATURE ACCURACY:            +/- 1 Deg. C CONTROL SYSTEM :                           PID (WITH PROGRAMMER)

    more..
  • Salt Fog Test Chamber

    Salt Fog Test Chamber

    Get Price Quote

    • Type: Salt Fog Chamber
    • Certification: CE Certified
    • Color: Available in Many Colors
    • Voltage: 220V
    • Application: Industrial Use
    • Power: 6-9kw

    The updated models of Salt/Cass Fog Test Chamber specially designed for evaluating the corrosion resistance of the surface treatment of metallic materials by Copper Accelerated Acetic Acid Salt Spray Test Method. It consists of following parts : Test Chamber : It consists of Cabinet and Lid and is constructed with insulated double structure made of FRP (Fiber Reinforced Plastic) Moulded Sheet. The Interior & Exterior Sides of the Chamber are Acid Proof, Alkali Proof, Impact Proof and easy to clean. The upper part (triangular shaped lid made of FRP with Acrylic Glass Window) has sufficient space for the mist to accumulate naturally on it and is so shaped that drops so accumulated do not fall on specimen being tested. A full top opening door will be provided for ensuring maximum working space inside the Chamber. Air-Saturator : It is provided to supply heated and humidified clean air, over 90% to 98% RH, for Atomization of the solution. It consists of Body (made of stainless steel), Heater, Bubbling Nozzle, Air Cleaner & Pressure Regulator. Air Regulator : The Air Regulator will maintain a constant pressure of air at 70 to 170 kpa Air Filter : The compressed air will be passed through a filter arrangement to remove all traces of oil and solid matters before sent to the saturation tower. Lid Sealing : Lid sealing through water seal method Mist Dispersion Atomizer : Atomizer made of Acrylic Glass will be equipped in the Chamber having property of non-choking. It produces a mist of atomized solution, which is distributed uniformly throughout the exposure zone by means of Mist Dispersion Atomizer incorporated with a baffle to prevent dispersion of large liquid droplets. Heating System : The temperature within the chamber maintained by heater with blower system, which provided in-between the exterior and interior walls. Solution Supply Tank : Solution Supply Tank will be provided to supply solution to Mist Dispersion Tower and will be made of FRP (Fiber Reinforced Plastic) Moulded Sheet. Solution Heating : Heating of solution in the Solution Tank by a special type of Glass Heating Element (two nos) fitted in the Solution Tank. Mist Collector : Two Mist Cylinders are provided for measurement mist quantity. Each has 80 cm² of horizontal area. The condensate is collected in individual graduated cylinders. pH Indicator : pH Indicator is inbuilt in Control Panel Control Panel : Separate Control Panel will be provided. The Control Panel will House : RH and Temperature Controller-cum-Indicator for Main Chamber. PID Temperature Controller-cum-Indicator for Air Saturating Tower. PID Temperature Controller-cum-Indicator for Solution Tank. Pre – Set Timer, ON/OFF Switches, MCB, Electronic Relays, Indicating Lamps & Time Totaliser pH Indicator.   Safety DeviceAudiovisual Alarm start at the time of shortage of water in both the Saturating Tower and Solution Tank. WiringAll wiring will be as IS code.  Channel type wiring will be done with suitable current rated copper wires.Standard Accessories SS Rod with PVC coating : 05 pcs Measuring Cylinder with Rubber Cork : 02 nos Glass Funnel : 02 nos S. S. Hanger : 15 pcs EPT Tube : 01 Mtr.                                                             Power Supply : 220/240 V, 50 Hz, Single Phase, AC Mains.                                                                                                                              Performance Test Temperature :  Ambient to 50°C Temperature Accuracy : ± 1oC. Humidity Range :  95% to 98% will be maintained during the Salt Spray with  saturation of Salt Solution. Humidity Indicator :  RH Indicator will measure 90% to 100%. Mist Collection :  1-3ml/80cm²/hour at the same position as specimen to be tested. Mist Pressure :  0.8-1.8Kg/cm² (70-170 KPA). Heating System :  Through hot air tower system.   Standards  : As per ISO 7253:1984, IS – 101 (Part 6/Sec 1 – June 1997), IS – 9000, IS – 6910, ISO – 3768 Part-I, ASTM – B – 117 – 73, ASTM – B – 368, DIN – 50021, JIS – 2371

    more..
  • Best Deals from Test Chamber

  • Dust Test Chamber

    Dust Test Chamber

    Get Price Quote

    For immaculate and easy to use Dust Test Chamber, you can completely rely on us. We are reputed Manufacturer, Supplier and Exporter of Dust Test Chamber from New Delhi, India. The construction of the Dust Test Chamber is designed to avoid direct radiation of heat on the test specimen. The floor of the Dust Test Chamber ensures that the dust falls in to the hopper for recirculation. Customers can avail the Chamber at competitive rates.   ConstructionThe construction of the Chamber will be such to avoid direct radiation of heat on the test specimen. The floor of the chamber will be so designed as to permit the dust fall in to the hopper for recirculation of supporting specified load of the floor area.Exterior Chamber : Will be made of 18 swg CRC M. S. Sheet with 3 coats of paint or 18 swg Stainless Steel   Interior Chamber : Made of 18 swg Stainless Steel Heating SystemFor temperature uniformity in the chamber, low surface loading sealed tubular heaters will be provided as per IS 4159. The heaters will be fixed in conditioning space in the chamber duly baffled to avoid direct radiation.Heat Input Controlling : Through Solid State Relay proportional control for heating.Dust Agitating Mechanism Dust Agitating Mechanism will be provided with Fan with Motor of sufficient capacity without allowing to heat up unduly during constant operation of 200 hours. Pressure Vacuum will be provided in the Dust Spray Chamber. Provision of using, either fan or vacuum or both can be used at a time, will be provided. Average dust sprayed will be 25 gms ±5 gms in 5 minutes. InstrumentationSolid State Digital Temperature Controller-cum-Indicator will be provided with PT-100 Temperature Thermocouple.Control PanelSeparate Control Panel on top of the Chamber will be provided with Contactors, On/Off Switches, Fuses, and Indicating Lamps.WiringThe wiring, will be channel type with suitable current rated copper wire as per, IS Code.Safety Protection Overload Protector for motor. MCB for heaters. Safety cut off thermostat with audiovisual alarm for over shooting temperature. Back up Fuse protection for mains and individual circuit.

    more..
  • Corrosion Test Chamber

    Corrosion Test Chamber

    Get Price Quote

    We are offering Corrosion Test Chamber. ENVIRONMENT TEST CONDITIONS: Environment temperature range: 15 ~ 60 Relative humidity: Less than 85%R.H. Atmosphere: 86 ~ 106 Kpa Without strong vibration around Without strong electromagnetic field around the influence, no high concentration of dust and corrosive materials Avoid direct sunlight or other heat source direct radiation Without strong airflow around, when the surrounding air should be forced to flow, flow should not blows directly to the body Machine should be placed flat, maintain the level, because the upper water seal to prevent salt fog spillover Around the machine there shall be a certain distance, convenient maintenance operation MACHINE INTERNAL: Spray tower (or baffle type): Invisible glass shower nozzle in nozzle interior, spray by tower tube guidance, then through conical disperser (or baffle) evenly dispersed spray to the laboratory internal. Spray regulator: Adjust spray amount, adjustable high spray on the conical disperser (or baffle) spray quantity increase, the lower the spray to decrease, brine preheater tank, located in spray bottom department, the tank brine is the brine added box injection preheating tank, the water level of preheating tank by floating ball control, automatic control level, the groove bottom have for washing port, port by silica gel plug control. Collector: Nozzle have eruptive fall fog quantity to free-fall way down to 80 cm of the funnel cup inside, again by duct flow to measuring cup inside. Shelf: The shelves of window of model steel is made, pool weight can't more than 2 kg, if place dispersedly samples, affordable 10 kg weight within the supporter and lined with two rows round hole, round hole is for placing buy object bar, vertical plane is divided into 15 degrees and 30 degrees. Heating water tanker: This tank adherent to the laboratory bottom, used to hold water humidifying keep laboratory temperature smooth, have added wet and heat preservation function. MACHINE EXTERNAL: Measuring pail: It collects the spray quantity, the highest scale is 50ml. Insulated tank: Use water principle, avoid salt fog were leaked. Saturated air barrel: Placed in control bottom part, USES the SUS304 stainless steel plate is made, its function lies in the air after the barrel warming humidification, allowing air to saturated humidity to the nozzle spray. Test cover: Roof type bevel 100 degrees perspective cover, and used to cover in the laboratory, combined as one body. Pressure regulating valve: Manual regulation inlet pressure and spray pressure inlet pressure control in 0.4 MPa, the spray pressure control in 0.07 ~ 0.17 MPa. Pressure meter: This table pointer shows pressure is air after saturated air barrel heating, communicate spray or reach pressure. Exhaust pipe: 1/2 diameter pipeline, combining drain to drain, make its wastewater which ruled out. Water inlet: Supplementary laboratory and saturation bucket of water to normal usage.

    more..
  • Ozone Test Chamber

    Ozone Test Chamber

    Get Price Quote

    subsonic wind tunnel, toxicity test apparatus, Polishing Lapping Machine

    more..
  • Corrosion Test Chamber

    Corrosion Test Chamber

    Get Price Quote

    Corrosion Test Chamber, Hardness Software, Abrasive Cut Off Wheels

    more..
Filter by Locality
top