  • Real Time Power Factor Control Panel

    Real Time Power Factor Control Panel

    Get Price Quote

    • Frequency50 - 60 Hz
    • Automation GradeAutomatic
    • Rated Reactive Power50 to 2500 Kvar
    • Voltage220V AC
    • Current68 A
    • Gross Weight35 Kg
    • We are engaged in offering technically advanced Real Time Power Factor Control Panel in the market. Real Time Power Factor Control Panel is modern power factor correction system having ability of correcting power factor in real time. Our Real Time Power Factor Control Panel is incorporated with high end measuring and complete harmonics free pollution and isolation circuits that are microcomputer based . We have equipped quickly responsive and advanced computing software in these panels. Our Real Time Power Factor Control is designed the reactive power on real time basis for extremely rapid acquisitions of power factor. Connecting and Disconnecting of capacitor to and from network occurs a zero crossing, which smooth the connections of the circuit . This smooth connection avoids transient effects such as waveform distortions, generating of switching spikes etc. Highlights : Longer service Incorporated with advanced technology Low operating cost Low maintenance Details : Our thyristor switching modules are built with state of the art switching circuits. The switching circuit continuously monitors voltage across thyristor and allows the thyristor to fire only & only if the voltage across the thyristor is zero. Thus the current through the thyristor always starts as if a normal load was switched on, and all the transients & switching pulses associated with other switching systems are totally absent. Because of this we do not use any di/dt reactors. Since the switching is independent of the remnant charge on the capacitor, we do not need any fast discharge resistors or reactors. Since switching in transients & pulses are totally absent, the capacitor life is enhanced several times. The entire system is saved from capacitor switching transients. When harmonics are present, the conventional formula PF=Cos Ǿ is not valid. In such cases PF= Cos Ǿ X Distortion Factor (DF depends on extent of harmonic pollution and is less than 1. Therefore we do not use Cos Ǿ sensing relays. Instead we use KVAR controller. Technical Specification : Operating Voltage   For 415V line to line configuration: 300 V~ to 500V~ For 240 V Phase to neutral configuration: 170V~ to 300V~ For 120V Line to Line configuration: 79V~ to 132V~   Current Input: 1A or 5A Capacitor Voltage: 1A or 5A 12V DC/20mA Solid state Output(Open Emitter) or Thyristor Switch Commands. Rating from : 100- 1200 KVAR Standard steps: 6 / 12.5/ 25 / 50 / 75 /100 KVAR System included De-tuned iron core that de-tuned the network to prevent the resonance and absorb the harmonics. Incomer- MCCB/ ACB Capacitor- 450V / 525 V Over temperature protection. Salient Features : The system is maintenance free because it does not use contactors for switching the capacitors. Enhance the capacity of distribution transformer, switchgear and HT cable. Power Factor will maintain almost near to unity so guaranteed P.F. bonus of 4 % to 5 % every month. Capacitors life is enhance minimum 3 to 4 times. Due to electronics switching & rectors available in the system. The reactors will filter the harmonics & prevents the possibility of resonance by shifting resonance frequency below 5th harmonics.
    ...more
    www
  • WPC Board

    WPC Board

    Get Price Quote

    WPC Boards are the best alternate for the traditional use of wood and plywood for its durability and thermoplastic for its flexibility. WPC Boards are the overcome of the entire problem faced with the plywood. WPC Board from Saiply have features such as highly resistant to extreme weather, moisture and termites and low maintenance. Saiply will outperform conventional timbers in many areas. The result is that Saiply WPC Board Product won’t rot, crack, warp or splinter (as long as installed and used as recommended) meaning you can rest easy for years.
    ...more
  • Power Distribution Board

    Power Distribution Board

    Get Price Quote

    Power Distribution Board, Electric Control Panels, Fuse Distribution Boar