Transducers Dealers in Mumbai

(97 products available)
  • Ultrasonic Therapy Transducer

    Ultrasonic Therapy Transducer

    Get Price Quote

    • ConditionNew
    • Frequency50hz
    • PowerElectric
    • PhaseDiouble Phase, Single Phase, Tripple Phase
    • Total Carbohydrate1yrs
    • Output12ma, 14ma, 16ma, 18ma, 20ma
    ...more
    www
  • Remote Control Encoder IC

    Remote Control Encoder IC

    120 - 180 / Piece

    • PackagingIndustrial Standard Packaging
    • ApplicationRemote Control Application
    • We are a noteworthy name when it comes to Encoder Decoder Ic that is the perfect outcome of premium material and advanced processing techniques. We are supported by a well-structured warehouse that assists us wholly in keeping the lot safe and meeting urgent requirements at a time. Also, we keep it updated on regular basis. The offered Remote Control Encoder IC is used widely for remote control application.
    ...more
    www
  • Industrial Ultrasonic Probe

    Industrial Ultrasonic Probe

    Get Price Quote

    • Country of OriginIndia
    • Power1200 W
    • Country of Origin12 to 24 V DC
    • Power1200 W
    • Transducer TypeUltrasonic
    • Usage/ApplicationIndustrial Automation
    • Usage/ApplicationIndustrial Automation
    ...more
    www
  • Industrial Immersible Transducers

    Industrial Immersible Transducers

    Get Price Quote

    • FeatureCompact size, Accurate reading, Leak-proof nature
    • MaterialSteel
    • Power900 W
    • Brand NameHighclean Ultrasonics
    • Frequency 28 KHz
    • Accuracy 93%
    • Dimension406 x 305 x 100 mm
    ...more
  • Voltage Transducer

    Voltage Transducer

    Get Price Quote

    We Offer Voltage Transducer. This transducer converts a sinusoidal AC Voltage signal into an output signal for Single Phase Single Output (STE-A-2T), Single Phase Dual Output (STE-A-2TD), Single Phase Triple Output (STE-A-2TT) & 3-Phase 4-Wire (STE-C-2TT), that can serves several receiving instruments such as indicators, recorders, alarm units etc. The input Voltage is scaled down using a Voltage transformer T. The output of the transformer is rectified and filtered in a precision absolute amplifier A, incorporating integrated circuits. The amplified filtered output is proportional to R.M.S value of the sine wave input. The output is fed to a current converter 'C' to provide a load independent D.C. Current. Feature � Available in accuracy class index -0.2, 0.3, 0.5 & 1.0 � Withstands wide temperature variations. � VA burden on PT very low. - < 0.5 VA � Wide range of Input / Output to meet National / International requirements. � Comply to revised IEC 60688 (1997-10) standards. � Flexibility in auxiliary power supply requirements - A.C. / D.C. � Rugged and vibration resistant. � Withstands seismic test as per IEC 344-1974 for Nuclear Power applications. � Available in dust proof sheet plastic enclosures suitable for Back panel / Din rail mounting. � Multiple outputs also available - up to 4. � High input / Output isolation - 4.0 KV.
    ...more
  • AC/DC Voltage Transducer

    AC/DC Voltage Transducer

    Get Price Quote

    • TypeVoltage Transducers
    • Output AccuracyHighly Accurate
    • AdjustmentExternal Span & Zero Adjustment
    • Power ConsumptionLow Internal Power Consumption
    • Output is highly accurate and stable External span & zero adjustment Low internal power consumption Compact DIN rail mounting Multiple output option provided Advantages: Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth and resistance to external interference Low disturbance in common mode Applications: AC variable speed drives and servo motor drives Static convertors for DC motors UPS Battery supplied applications Power supply for welding PLC, SCADA, Tele metering, Data logging etc.
    ...more
  • Rochester Analog Transducers

    Rochester Analog Transducers

    Get Price Quote

    Broad family of products Direct drop-in replacements for older models Field proven reliable design Models for any circuit type, input, output and power
  • Immersible Ultrasonic Transducer

    Immersible Ultrasonic Transducer

    Get Price Quote

    Life-Care "Fast - Clean" Immersible Ultrasonic Transducers can be placed wherever you need them in your existing cleaning tanks. These units give you complete freedom to design specialized cleaning setups or to upgrade pre-soak tanks with ultrasonic.
    ...more
  • Frequency Transducers

    Frequency Transducers

    Get Price Quote

    We are offering frequency transducer ste-a_5t converts a frequency into an output signal that can serve several receiving instruments such as indicators recorders, alarm units etc. The input voltage signal is stepped down and galvanically isolated by a transformer t. The zero crossing of the signal is detected to triger a precision quartz controlled monostable circuit q. For each cycle of the input signal, the monostable switches a highly stabilized d.c.voltage to an amplifier a. The output of the amplifier, a constant voltage with fixed pulse width is filtered and averaged. The average signal is proportional to the frequency of the input signal. To suppress the initial range, for instance up to 45hz a fixed voltage is subtracted. The difference is fed to a current converter c to provide a load independent d.c. Current output, which can be either bipolar or unipolar
    ...more
  • Current Transducer

    Current Transducer

    25,000 / Piece

    • Transducer TypeCurrent Transducer
    • Country of Origin220 V
    • Power1000hp
    • Measuring CurrentAC
    • Part NumberES1000
    • Usage/ApplicationAutomotive
    ...more
  • Power Transducers

    Power Transducers

    Get Price Quote

    Terminal Protection Cover Reliable & Rugged Static Circuits Low Ripple in outputs Signal Flame Retardant Polycarbonate case Choice of Multiple Asymmetrical Outputs Wide Choice of Suppressed Ranges Open and Short Circuit Protection for Outputs Dual Outputs (Non Isolated Isolated) Self – Powered, AC, DC Auxiliary Supply Bi-directional Output Fast Response Time Din-Rail Mounting Bi-Directional Inputs for Import Export input
    ...more
  • Frequency Transducer

    Frequency Transducer

    Get Price Quote

    • Accuracy± 0.5% of Rated output, ± 0.2 % (Optional)
    • Output Ripple0.2% RMS
    • ResponseLess than 0.5 Sec.
    • Storage Temp-20°C
    • Overload Continuous 22 x Rated Current, 1.2 x Rated Voltage
    • Breakdown Impulse Voltage4.5KV , 1 x 40µs (without dewing.)
    • MECO-G" AC Frequency Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications.
    ...more
  • Current Transducer

    Current Transducer

    Get Price Quote

    • Brand NameHANGZHI
    • MaterialOther
    • ConditionNew
    • PowerElectric
    • Power Supply15 V DC
    • FeatureAccurate Results, Durable, Excellent Performance, High Quality
    • Country of Origin15VDC
    • The high-precision open-loop current sensor utilises fluxgate technology to address the issue of low current detection accuracy found in existing open-loop current sensors within the industrial sector. By applying a multi-point zero-flux technology system to the current high-precision open-loop sensors, it combines excitation flux closed-loop control, self-excitation fluxgate technology, and multi-closed-loop control technology to achieve zero-flux closed-loop control of excitation flux, DC flux, and AC flux. A high-frequency ripple sensing channel is constructed to detect high-frequency ripples, enabling the sensor to maintain high gain and measurement accuracy across the full bandwidth range.   The sensor is designed for electronic current measurement: DC, AC, and pulse, providing current isolation between the primary and secondary circuits. It complies with EMC standards (EN61000-3-2:2014, EN 61000-6-4:2007+A1 (2011), EN61000-3-3:2013, EN61000-6-2:2005) and safety standards (EN 61010-1:2010+A1 (2016), IEC61010-2-030:2017).   Application Fields: New Energy: Power analyzers and power meters supporting on-site calibration Power Distribution System Upgrades: Applications such as DC power system upgrades in power plants, substation DC system upgrades, communication room upgrades, and railway locomotive retrofitting Live Operation in Power Distribution Networks Other Applications Where Equipment Operation Cannot Be Interrupted The temperature-compensated (closed-loop) current sensor employs an extremely precise zero-flux detector fluxgate technology (HANGZHI patents: ZL201820961112.7/ZL201820371736.3/ZL201820383681.8/ZL201922233758.0/ZL201820962443.2/ZL201820373225.5/2021SR0931672). IPN: ±400 Connection: Phoenix terminal Mounting: Plane or vertical panel installation Features: Electrostatic shielding between primary and secondary circuits Optical isolation output (optocoupler) indicating sensor status LED indicator confirming normal operation Outstanding linearity across the entire temperature range Best-in-class accuracy with excellent linearity Ultra-low temperature drift 350kHz wide frequency bandwidth High immunity to external fields Power supply: ±15V (Min: 14.25V, Max: 15.75V) Temperature range: -30°C to +75°C DC current measurement range: -480A to +480A AC current measurement range: 283A Response time: 2μs Accuracy: 0.05% Product Series: CIT series Brand: HANGZHI Part Number: CIT 400 Specifications: EN     All product and company names are trademarks or registered trademarks of their respective owners. Their use does not imply any affiliation or endorsement.  
    ...more
    www
  • Series 672 Low Pressure Transducer

    Series 672 Low Pressure Transducer

    Get Price Quote

    The Series 672 Low Pressure Transducer is a perfect solution to any application where a very accurate low pressure transducer is necessary. Using variable capacitance technology, the Series 672 is designed to measure pressures as low as 10" w.c. up to 400" w.c., very low ranges for a single connection pressure transducer. The 672 also features a 0.25% F.S. accuracy. Use the Series 672 in liquid level, flood warning, waste water, clean room, and open channel flow applications.
    ...more
  • HDA 4300 Pressure Transducer

    HDA 4300 Pressure Transducer

    Get Price Quote

    Available versions: Standard; ATEX; CSA; Schiff & Offshore; with front-flush diaphragm The The pressure transducer series HDA 4300 is equipped with a ceramic pressure measurement cell with thick-layer DMS, which was specially developed for relative pressure measurement in the low-pressure range. The 4 ... 20 mA or 0 ... 10V enable the connection to all measurement and control devices of HYDAC ELECTRONIC GmbH and the linkage to commercially available control and regulation units. The variant with the front-flush diaphragm was specially developed for applications in which the media used could lead to a blockage, gumming-up or freezing of a standard pressure connection. The main areas of application lie in the low-pressure ranges of hydraulics and pneumatics, particularly in refrigeration and air-conditioning, food and pharmaceutical industry applications. Further applications include processes where the medium changes frequently and any residues could cause mixing or contamination of the media.
    ...more
  • Power Transducers

    Power Transducers

    Get Price Quote

    Meets to DN-IEC 688. • Easy Installation & Space saving. • Simultaneous detect & display : - Individual Phase to neutral Voltage - Individual Phase Current - Individual Phase watt. - Frequency - Phase to Phase Voltages. - - Power Factor - - Total Watt - - Total Var - - Watt Hour (10 digit)
    ...more
  • Transducers

    Transducers

    Get Price Quote

    Nippen power line transducers give load independent and isolated dc outputs proportional to input parameters like current, voltage, frequency, power factor, active power, reactive power and dc isolation. a c voltage frequency pf active power reactive power d c isolation
    ...more
  • Honeywell Pressure Transducers

    Honeywell Pressure Transducers

    Get Price Quote

    • MOQ5 Piece
    • Accuracy+-0.25 %FSS
    • BrandHoneywell
    • Current Rating3A
    • Model Name/NumberHoneywell's PX3 Series Heavy Duty Pressure Transducers
    • Ambient Temperature-40 C to 125 C [-40 F to 257 F]
    • Ce ConformityYes
    • Mounting TypeBrass housing and Metri-Pack 150,DIN,or cable harness electrical connections
    • Short Circuit ProtectionYes
    ...more
  • Ultrasonic Transducer

    Ultrasonic Transducer

    Get Price Quote

    We are known as the chief Ultrasonic Transducer Manufacturer and Supplier in India. Our Ultrasonic Transducer is available in different series that varies from 25 KHz to 50 MHZ. Moreover, the Ultrasonic Transducer can be acquired at affordable prices from us. Features Optimum acoustic Electrical parameterA novel dual damping concept Series Available W -Series : W Series represents white frequency: The transducer of this series generate a white frequency signal, and represents high signal to noise ratio, high resolution and narrow initialpulse. W-Series transducers are recommended for thickness gauging and close surface material inspection.K -Series : K Series stands for characteristic transducers. Transducers of this series have high sensitivity, moderate signal to noise ratio and high penetration. They are tuned to a particular frequency and are suggested for deep material penetration, bulk body defects resolution, shear waveapplication and investigation of attenuative media.P -Series : P Series represents Panacea Transducers. P series transducers have response falling between W and K series. They have sensitivity closer to K series and Resolution closer to W Series making them ideal for all general purpose NDT application.N-Series : This new series has features like low initialringing offering better near surface resolution, sharp echoesfor higher overall resolution, high signal to noise ratio incoarse material and high reserve gain.
    ...more
  • I/P Converter

    I/P Converter

    Get Price Quote

    • FeatureDurable, Excellent Performance, High Quality
    • MaterialStainless Steel
    • Number Of FlowerElectro Pneumatic
    • MYKO 500 MK Series transducers are ideally used to convert current or voltage input signal to a nearly proportional pneumatic output pressure. This versatile instrument is rugged and reliable force balance transducers for use in both process control and industrial applications, for standard process control applications which typically utilise 3 to 15psig output and industrial & high pressure application which typically utilise pressure output up to 120 psig.MYKO 500MK Series transducers combines low cost, high accuracy and minimum air consumption with field proven technology. Versatile design features and rugged, compact housing with a choice of CMRI and ATEX* approved versions for explosion proof or intrinsically safe operation when used with a suitable barrier.Principle of OperationMYKO 500 MK Series transducer is a force balance device in which, when electrical current is passed through the coil of transducer magnetic field is created which acts on the magnet assembly, casuing the anvi & diaphragm to move away from or forward the nozzle (flapper nozzle) depending on the direction of current flow. Motion at the nozzle assembly is proportional to the amount of current passing through the coil.The flapper/anvil move away from or forward towards the nozzle creates back pressure which acts as pilot pressure to an integral booster relay. when input electrical current increases (or decreases for reverse acting) causes proportional output pressure increases.Zero and Span are calibrated by turning easily accessible adjusting screws on the front face of the unit. The zero adhusting screw causes the nozzle to move relative to the flapper/anvil. The span adjusting screw is a potentiometer that limits the current through the coil. A thermistor circuit in series with the coil provides temperature compensation.Integrated Characteristics Compact Design. Low Air Consumption. Integral Volume Booster-flow capacity up to 20 SCFM is boosted by the built in Volume booster. Field Reversible – Output provides inversely proportional to input signal. Flexible Adjustments of Zero & Span. Standard Process Inputs. Split Ranging NEMA 4X (Ip65) Enclosure - Optional Applications500MK Series transducers converts electrical signal to a pneumatic output which can be used to operate the fallowings : Valve, Valve-Actuators, Damper and Louver Actuators Valve Positioners Air-Cylinders Relays Clutches Web Tensioners and Brakes Used in : Petrochemical Processing Systems Energy Management HVAC Systems Textile Processing Systems Pharmaceutical Processing System Clutches Pulp and Paper Handling Controls
    ...more
    www
  • Ion Selective Electrodes

    Ion Selective Electrodes

    Get Price Quote

    Salient Features INTRODUCTION The concentration of Ions and gases in solution may be determined using ion selective electrodes. When a suitable sensing electrode is immersed in a solution containing ions or gases, an electrical potential may develop at the electrode surface due to a selective spontaneous reaction. The magnitude of this potential varies with the concentration of the selected ion or gas ISEs are responsive to concentration of particular ions in the test liquid and are variable-potential electrodes. When measurements are made using an ion meter, by calibrating with various standard solutions, direct readings of the concentration of the ion can be taken. Slope of the electrode depends on the temperature therfore measurements must be taken at a fixed temperature. SOLID STATE ELECTRODES are as combination electrodes complete with reference electrode. These electrodes incorporate a solid sensing surface made of compressed silver halides, or solid crystalline material. A solid state electrode develops a voltage due to ion-exchange occurring between the sample and the inorganic membrane. An equilibrium mechanism occurs due to the very limited solubility of the membrane material in the sample. GAS SENSORS are combination electrodes that detect dissolved gases in a solution. No external reference is required for these electrodes. The sensing element is separated from the sample solution by a gas permeable membrane A gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film is the same. The pH change is proportional to the dissolved gas in the sample STORAGE AND CLEANING It is sufficient to store the electrode in a standard solution during short measuring intervals. In order not to strain the membrane unnecessary, the electrode should be stored dry if it is not used for several days. After the dry storage put into standard solution for 3 - 4 hours for new measurements. Contaminations should be removed with a wet paper towel, don’t use organic solvents like acetone.   No Reference electrode needed Solid state sensors Refillable Type Our ISEs are compatible with other make Ion / pH meter Direct measurement of Ionic concentration Standard supply with ISAB & Calibration Solutions Refillable Type Virtually unbreakable Fast response no maintenance No membranes or replacement module
    ...more
  • Melt Pressure Transducers

    Melt Pressure Transducers

    Get Price Quote

    The PT460E Series transducer is a ±0.5% sensor ideal for melt pressure applications requiring simple installation, repeatability and reliability. The PT460E transducers provide the industry standard 3.33 mVV signal designed to work with most pressure indicators. The PT460E comes equipped with a six pin bendix connector. Optional thermocouple or RTD configurations are available to provide melt temperature. The PT460E features a 12-20 UNF thread for installation in standard transducer mounting holes and can be supplied with a variety of other electrical connections if desired.
    ...more
  • Oxygen Measuring Transducer

    Oxygen Measuring Transducer

    Get Price Quote

    • Response Time90% of reading (T90) less than 30 seconds
    • Measurement Rangesppm variant 0-10ppm, 0-100ppm, 0-1000ppm, 0-25% (for air calibration)
    • Resolution0.1% of range or better
    • Signal Outputs4-20mA (2 wire), RS232 or RS485
    • Ambient Temperature0 to +50 deg C
    ...more
  • Melt Pressure Transducers

    Melt Pressure Transducers

    Get Price Quote

    • Pressure Range0-3.5MPa--0-150MPa(0-500psi---0-30000psi)
    • Over Pressure1.5 X FSO
    • Max Diaphragm Temperature400oC
    • MA1200 Series Economic melt Pressure Transducer designed for economic applications. The model MA1200 and MA1300 are introduced with automatic zero adjustment. This series can be used together with the PVI Series Intelligent Digital Pressure Instrument of Omicron or other brand instrumentation. Zero & full span can be adjustable externally if required, with amplify signal can be connected with PLC. With the advantage of high precision and reliable pressure measuring and good quality, internal 80% calibration and etc.
    ...more
  • Transducers

    Transducers

    Get Price Quote

    NIPPEN Power line Transducers give load independent and isolated DC outputs proportional to input parameters like current, voltage, frequency, power factor, active power, reactive power and dc isolation. Features A C VOLTAGE. FREQUENCY PF ACTIVE POWER REACTIVE POWER D C ISOLATION Features Linear aux. power supply of 230V AC. Conforms to IEC 60688 and IS 12784. Short circuit protected and open circuit proof. High input/output isolation 3kV/ 4kV. DIN RAIL/ Back panel mounting arrangement. Wide choice of outputs and suppressed ranges. Current or voltage output. Single or dual ISOLATION.
    ...more
  • Current Transducer

    Current Transducer

    Get Price Quote

    RAYS AC Isolation transducers accepts various AC Inputs depends on the model selected. We offer Different AC Input models ranging from 0-1 A AC, 0-2 A AC, and 0-5A AC models with different auxiliary supply. For any higher range use external CT to convert and use it for higher current applications.Models available on request with different Aux and Input range. Features: Output is ripple free , and user adjustable zero and span access control. Transducers are normally factory set for Zero and Span for the Input range ordered.   Other Details Isolated output (3.0 KV) Excellent linearity Enclosures suitable for DIN RAIL mounting /Flush mounting Ex-Stock delivery or within 2 weeks Models available on request with different Aux and Input range User adjustable Zero and Span control Enclosure size : 42 x 75 x 125mm Power ON LED Indication for all models 12 months warranty Operating temp : 0-60 deg C Accuracy +/- 0.25 % Output with 0-5/10 Volts options available ( optional) DUAL output (Optional)
    ...more
  • IP Converter

    IP Converter

    Get Price Quote

    • Overall dimensions550Wx300Dx400H mm
    • The IP and PI converter setup is designed for understanding basic principles of electronic and pneumatic signal conversion. The setup consists of IP converter, PI converter, digital calibrator, pressure gauges and air regulator and air filter regulator. The Digital calibrator is used as current source to supply 4-20 mA DC to IP converter and to measure the output current in mA DC from PI converter. IP converter gives the output as 3-15 psig and PI converter gives output as 4-20 mA DC.
    ...more
  • Elap Digital Linear Transducers

    Elap Digital Linear Transducers

    22,000 / Piece

    • Brand NameELAP
    • Model Name/NumberPD 100
    • Supply Voltage5 VDC or 10-24 VDC
    • Stroke Length60 mm
    • Stocking Temperature-20 Deg C To 70 Deg C
    • Max Speed60 m/min
    • Protection DegreeIP6
    • Progress Strength1 / 3 N
    ...more
  • Single Phase Powerline Transducer

    Single Phase Powerline Transducer

    Get Price Quote

    • Number Of FlowerTransducer
    • Input TypesAC Current 0-5 AAC
    • Output SignalDC Output Signal 0-10VDC/4-20mADC
    • Supply90-270VAC
    • Isolation Level3.5 KV
    • EnclosureABS Plastic
    • The CANPWR 1.0 Powerline Transducers for Single Phase measurements are useful in remote monitoring of Pow measurements erline parameters. These are intelligent Transducers designed with the latest state of art technology and provide flexibility of SW configuring the parameters to suit the application requirements.True RMS measurement of Input Voltage (Vac) & Current (Iac) ensures accuracy in measurement and computation of various parameters, Viz. Vac, Iac, Frequency, Power Factor, Power (ActiveReactiveApparent). (ActiveReactiveApparent).The CANPWR 1.0 Powerline Transducers interface with AC voltage (e.g. 0-110230440 V) & AC Current (CT signals: 0-1A, 0-5A) inputs to provide isolated 0-10V4-20mA DC output accurately proportional to the parameter to be measured. Provision is available for up to 4 nos. of Isolated 0-10V4-20mA outputs to enable interface with multiple data acquisition systems. Additionally, RS485
    ...more
  • Ultrasonic Transducer

    Ultrasonic Transducer

    Get Price Quote

    The success of any Ultrasonic technique depends heavily upon the capability of a transducer to function in accordance with a particular application. RTUL is the leading manufacturer of reliable high performance transducers for all ultrasonic applications. RTUL offers one of the most comprehensive selections of ultrasonic transducers that encompass all non-destructive testing and process applications. Highlights of RTUL transducers: Design To cover all applications four distinct series are offered. Each series is characterized by its own unique set of optimum acoustic and electrical parameter. A novel dual damping concept is feature in each transducer type. Materials The selection and formulation of each transducer undergo strict laboratory criteria of testing and assembly. This has eliminated problems such as weak housing, weak bonding etc. RTUL transducers surpass all other commercially available units in wear and impact resistance and are not only long lasting but also are highly suitable inrugged applications. Fabrication For precise location of discontinuities special techniques have been developed that assure perfect alignment of geometric and acoustic centers. ULTRASONIC TRANSDUCER SERIES : Since a single transducer is not capable of performing a large number of applications, it is imperative that a number of ultrasonic transducers be designed in order to accomplish comprehensive material inspection. RTUL offers three distinct transducers series from 25 KHz to 50 MHZ. Each series is characteristically different from the other, thus suitable for a particular application. Some of the features of these series are given below. W -Series Probes W Series represents white frequency: The transducer of this series generate a white frequency signal, and represents high signal to noise ratio, high resolution and narrow initial pulse. W-Series transducers are recommended for thickness gauging and close surface material inspection. K -Series Probes K Series stands for characteristic transducers. Transducers of this series have high sensitivity, moderate signal to noise ratio and high penetration. They are tuned to a particular frequency and are suggested for deep material penetration, bulk body defects resolution, shear wave application and investigation of attenuative media. P -Series Probes P Series represents Panacea Transducers. P series transducers have response falling between W and K series. They have sensitivity closer to K series and Resolution closer to W Series making them ideal for all general purpose NDT application. N-SERIES Probes This new series has features like low initial ringing offering better near surface resolution, sharp echoes for higher overall resolution, high signal to noise ratio incoarse material and high reserve gain.
    ...more
Filter by Locality
top