    Akron Brass Fire Hose Nozzles

    Akron Brass Fire Hose Nozzles

    Get Price Quote

    • MOQ1 Meter
    • MaterialBrass
    • Country of OriginIndia
    • Brand NameAkron
    • ApplicationFire Fighting
    • Size10.5 Inch
    • Operating Pressure5, 6 Or 7 Bar
    ...more
    www
  • Fire Hydrant Systems

    Fire Hydrant Systems

    Get Price Quote

    We provide a comprehensive range of fire hydrant systems that are commissioned on a turnkey basis. These fire systems can easily detect fire in the initial stage and can be controlled automatically by dialing to the fire brigade authority. These projects are handled by our qualified team of personnel, who have vast experience in their respective field. Highly cost effective, our range of systems is known for their reliability and durable performance. Further, we also consider the specific requirements of the clients while installing these systems
    ...more
  • Fire Hydrant Pumps

    Fire Hydrant Pumps

    Get Price Quote

    • ApplicationFire Hydrant System
    • Number Of FlowerOutdoor Fire Hydrant
    • Brand NameEfficient Fire
    • Power10-250 HP
    • ConnectionWelded
    • MaterialCast Iron
    ...more
  • Fire Hydrant Pump

    Fire Hydrant Pump

    Get Price Quote

    • Number Of FlowerIndoor Fire Hydrant, Outdoor Fire Hydrant, Rotating Fire Hydrant, Underground Fire Hydrant, Double Outlet Fire Hydrant
    • MaterialMS, Cast Iron, GI
    • Minimum Order Quantity1 Unit
  • Fire Pump

    Fire Pump

    Get Price Quote

    A fire pump is a part of a fire sprinkler system water supply and powered by electric, diesel or steam. The pump intake is either connected to the public underground water supply piping, or a static water source (e.g., tank, reservoir, lake). The pump provides water flow at a higher pressure to the sprinkler system risers and hose standpipes. A fire pump is tested and listed for its use specifically for fire service by a third-party testing and listing agency, such as UL or FM Global.Fire pumps function either by an electric motor or a diesel engine, or, occasionally a steam turbine. If the local building code requires power independent of the local electric power grid, a pump using an electric motor may utilize, when connected via a listed transfer switch, the installation of an emergency generator.The fire pump starts when the pressure in the fire sprinkler system drops below a threshold.
    ...more
  • Short Branch Pipe Nozzle

    Short Branch Pipe Nozzle

    Get Price Quote

    • ApplicationFire Fighting
    • MaterialStainless Steel
    • Hydraulic Test21 kgf/cm2
    • TechniqueHot Rolled
    • Length63 mm
    ...more
  • Suction Collection Head

    Suction Collection Head

    Get Price Quote

    4/3/2 Way Suction Collection Head Consist of 4/3/2 nos. 63mm Size (GM) Male Instantaneous coupling as per IS: 903 with NRV
  • Fire Diesel Pump

    Fire Diesel Pump

    350,000 / Piece

    • MOQ1 Piece
    • ApplicationIndustrial
    • Country of Origin230 V
    • BrandKirloskar
    • Motor Horsepower58 HP
    • MaterialSteel
    • Frequency50 Hz
    ...more
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Fire hydrant system manufacturer and supplier in the market. Our fire hydrant system is manufactured with the use of the best quality components and materials ensuring superior performance and durability at the user end. We provide complete installation service for fire hydrant system. Made as per the approved industry standards, our fire hydrant system is well-tested by the experts for flawless functioning. applications industrial / non industrial buildingsinstitutional buildings residential apartments hotel & hospitals mall & multi storied complexes chemical & flammable storage yards
    ...more
  • Fire Hose Reel Drum

    Fire Hose Reel Drum

    Get Price Quote

    • MOQ100 Piece(s)
    • MaterialM.S Sheet
    • Material QualityNon-Corrosive
    • SWG18
    • We are offering high quality range of Fire Hose Reel Drum to customers all over the world. Our Fire Hose Reel Drum is fabricated using M.S. Sheet material with 18 SWG. It is horizontal mounting type which can accommodate up to 30mtrs, 19mm/25mm of hose pipe. We are a prominent Fire Hose Reel Drum Manufacturer, Exporter and Supplier in Maharashtra (India). Customers can avail our Fire Hose Reel Drum within a reasonable price range. Details : Rubber / PVC Braided Hose Non-corrosive working parts
    ...more
  • Portable Fire Pump

    Portable Fire Pump

    Get Price Quote

    • ApplicationFire Fighting
    • Country of OriginMade in India
    • CoatingPortable Fire Pump
    • Model Name/NumberPortable Fire Pump
    • SeriesSinge Stage Centrifugal
    ...more
  • Fire Fighting Water Monitor

    Fire Fighting Water Monitor

    15,500 / Piece

    • ApplicationIndustrial
    • MaterialGun Metal and SS
    • Flow Rate20 to 200 L/sec
    • Flow20 to 200 L/sec
    • Range50 to 60 m
    • Working pressure range1.0 to 1.4 Mpa
    ...more
  • Fire Fighting Pump

    Fire Fighting Pump

    Get Price Quote

    APES is one of the leading manufacturer and the largest supplier of Fire Fighting Pumps in India. Our pumps are designed to perform in extreme conditions most effectively and are build with high quality and superior technology. Our Fire Figthing pumps are used by many Fire Fighting departments in India and with utmost performance for many years. High quality Aryan portable pumps are designed to perform in extreme conditions with wide range of performance. These pumps deliver up to 24 Bar and 2600lpm. Apart from firefighting and de-watering, these pumps can be used effectively for dust suppression, water relaying, boosting, de-chocking and many more similar applications, using special tools.
    ...more
  • Fire Hydrant System +14

    Fire Hydrant System

    Get Price Quote

    Being one of the oldest but yet the most effective and common fire fighting solutions , as well designed and laid out Hydrant system forms the backbone of the entire  fire fighting system.We are highly acknowledged as the best Service Provider of Hydrant System Fire. It is highly demanded in various buildings or premises, widely used for fire fighting solutions and helps in controlling fire during an emergency. This system is designed to suppress the fire and provide a readily available source of water to any point. Under the supervision of our team of well-trained professionals, the offered system is installed by using the modern tools & techniques and quality-tested components. Apart from this, we are offering the Hydrant System Fire in different specifications at affordable prices.The fire hydrant systems are access points that allow fire authorities to connect hoses and quickly disperse large amounts of water to extinguish flames.The system mainly consists of by a number of components & accessories like Fire pumps ( Jockey Pump, Electric Driven Pump, & Stand-by Diesel driven pump) Fire pumps are usually housed in a pump room very close to the fire tanks. The key thing is that the pumps should be located at a level just below the bottom of the fire tank, so that all the water in the tanks can flow into the pumps by gravity.Like all important systems, there must be backup pumps in case the main pump fails. There is a main pump that is electric, a backup pump that is electric, and a second backup pump that is diesel-powered, in case the electricity fails, which is common. Each of these pumps is capable of pumping the required amount of water individually - they are identical in capacity.There is also a fourth type of pump called a jockey pump. This is a small pump attached to the system that continually switches on to maintain the correct pressure in the distribution systems, which is normally 7 Kg/cm2 or 100 psi. If there is a small leakage somewhere in the system, the jockey pump will switch on to compensate for it. Each jockey pump will also have a backup., The capacity of the pumps is decided by considering a number of factors, some of which are:the area covered by hydrants / standpipes and sprinklers The number of hydrants and sprinklers The assumed area of operation of the sprinklers The type and layout of the building Dry Rising Main (Dry Riser). A vertical pipe installed in a building for fire fighting purposes, fitted with inlet connections at fire engine access level and landing valves on various floors, which is normally dry but is capable of being charged with water usually by pumping from fire engine pumps. Dry rising mains are basically dry water pipes. The empty mains need to be charged with water through the breeching inlets by fire appliance. The dry rising mains should not exceed 60m to avoid excessive pumping pressure.Wet Rising Main (Wet Riser). A vertical pipe installed in a building for fire fighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves on various floors. Wet rising mains are constantly charged with water that provide the required flow rate and pressure for fire fighting and equipped with water storage capacity for a given duration of 60 minutes. The breeching inlets, which are usually provided at ground level, are meant for replenishing the water tank.The distribution system consists of steel or galvanised steel pipes that are painted red.  These can be welded together to make secure joints, or attached with special clamps.  When running underground, they are wrapped with a special coating that prevents corrosion and protects the pipe.   External (Stand Post Type Or Underground Type – Sluice Valve, Water Monitor)The amount of water in the fire storage tanks is determined by the hazard level of the project under consideration.  Most building codes have at least three levels, namely, Light Hazard (such as schools, residential buildings and offices), Ordinary Hazard (such as most factories and warehouses), and High Hazard (places which store or use flammable materials like foam factories, aircraft hangars, paint factories, fireworks factories). The relevant building code lists which type of structure falls in each category. The quantity of water to be stored is usually given in hours of pumping capacity. In system with a capacity of one hour, the tanks are made large enough to supply the fire with water for a period of one hour when the fire pumps are switched on.  For example, building codes may require light hazard systems to have one hour’s capacity and high hazard 3 or 4 hours capacity.  The water is usually stored in concrete underground tanks. It is essential to ensure that this store of water always remains full, so it must have no outlets apart from the ones that lead to the fire pumps. These tanks are separate from the tanks used to supply water to occupants, which are usually called domestic water tanks. Designers will also try and ensure that the water in the fire tanks does not get stagnant and develop algae, which could clog the pipes and pumps, rendering the system useless in a fire.Guidelines and approval for hydrant system are available from various national and international organizations like NBC, NFPA,TAC,IS,FM & Local Authorities.
    ...more
  • Fire Brigade Inlet

    Fire Brigade Inlet

    4,300 / Piece

    • TypeInlet
    • UsageIndustrial
    • Size63 mm 
    • Connection TypeFlanged
  • Portable Fire Fighting Pumps

    Portable Fire Fighting Pumps

    Get Price Quote

    Apes is one of the leading manufacturers of engine driven portable pumps in india. High quality aryan portable pumps are designed to perform in extreme conditions with wide range of performance. These pumps deliver up to 24 bar and 2600lpm. Apart from firefighting and de-watering, these pumps can be used effectively for dust suppression, water relaying, boosting, de-chocking and many more similar applications, using special tools. Aryan pumps offers a broad selection of gasolinediesel engines from the leading engine manufacturers with dependable service back up worldwide.
    ...more
  • Portable Fire Pump

    Portable Fire Pump

    Get Price Quote

    portable pumps are designed to perform in extreme conditions with wide range of performance. These pumps deliver up to 24 Bar and 2600lpm. Apart from firefighting and de-watering, these pumps can be used effectively for dust suppression, water relaying, boosting, de-chocking and many more similar applications, using special tools. Salient Features : Pumps available in Power ranging from 6.1 HP to 70 HP. Up to 4 stage centrifugal pumps in Aluminium Alloy or Bronze material construction. Fitted with Carbon Ceramic Mechanical Seal or Gland Pack. Supplied with screw down type delivery valve. Primes upto 7 meters depth with the help of very effective Priming System.
    ...more
  • Fire Hose Reel

    Fire Hose Reel

    4,650 / Piece

    • Diameter65mm
    • Pressure0.8 MPa
    • FeatureHeat Resistant
    • Hose ColorRed
    • Surface FinishingColor Coated
    • ShapeRound
    • Reel length10-50 m
    • Hose MaterialTPU
    ...more
  • Fire Fighting Sprinkler Pump

    Fire Fighting Sprinkler Pump

    135,000 / Piece

    • Power0.37 -160 kW
    • MaterialMild Steel
    • Capacity1.1-1450 m3/h
    • Speed2900 RPM
    • Pump Head6 m to 230 m
    • Outlet Diameter150mm to 1600mm (6"up to 64")
    ...more
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    We are involved in the manufacturing and supplying of highly efficient Fire Hydrant System. Only superior grade parts and components are used for the manufacturing of our Fire Hydrant System. Moreover, the production process is carried out under the supervision of experts and thus there are minimal chances of defects at buyer’s end. We offer Fire Hydrant System at market leading rates.
    ...more
  • FIRE FIGHTING PUMPS ,CONTROL PANEL

    FIRE FIGHTING PUMPS ,CONTROL PANEL

    Get Price Quote

    We offered an excellent range of Fire Fighting Pumps to the esteemed clients, as per their specific requirements. Fire Fighting Pumps have horizontal back pull out design, which ensures their easy inspection & maintenance. Moreover, their engineered enclosed impellers ensure smooth and efficient operations of these pumps. TECHNICAL FEATURES Capacity Up to 350 m /hr Head Up to 88 meters Temperature - Up to 70 C Capacity Up to 350 m /hr Head Up to 88 meters Temperature - Up to 70 C Delivery sizes 32 to 150 mm Casing Pressure Up to 16 Kg/cm SPECIFICATIONS Flanges in accordance with DIN2533 PN16 Horizontal Back Pull Out Design for easy inspection and maintenance Engineered Enclosed Impellers for smooth and efficient operation Robust Bearing housing Deep groove ball bearing for longer operating hours & bearing life
    ...more
  • Fire Hydrant Pump

    Fire Hydrant Pump

    30,000 / Piece

    • MOQ1 Piece
    • ApplicationFire Fighting
    • Number Of FlowerOutdoor Fire Hydrant
    • Country of OriginMade in India
    • MaterialMS
    • Motor HP5 HP
    • PhaseSingle Phase
    • Working Temperature-5 To 55 Degree C
    ...more
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    we have gained huge respect for manufacturing and supplying Fire Hydrant Equipments. These equipments are precisely manufactured at our state-of-art manufacturing unit by making use of optimum quality LBT-2 & aluminum alloy materials and hi-tech equipments.
    ...more
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Fire Fighting Hydrant System are used systems in residential and industrial projects to fight and prevent the spread of fire. A Red colour pipe of either Mild Steel or Galvanised Steel is used to circulate around the building or factory premise is known as a Fire Hydrant Pipe. In event of a fire, when you see a fireman shooting water up to 100 feet or more then the fire man is using a Fire Hydrant System. Such is the power of the Fire Hydrant System that water can be shot right up to directly into the fire.
    ...more
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    The hydrant system comprises of ac motor driven pump sets with all required accessories including valves, instrumentation and controls etc. complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent.
    ...more
  • Fire Hose Reels

    Fire Hose Reels

    Get Price Quote

    Technicai Specifications Type : Swinging 1800 Wall Mounting Size : Intel 20mm (3/4" BSP Thread Size) Conforming Specification : IS 884    Performance Test • Hydrostatic Test: Tested at 21 Kgf/cm2 • Range & Water Flow rate test at 7 Kgf/cm2 (A) Discharge : 24LPM (B) Range (Jet Length) : mtr(min)    
    ...more
  • Fire Pump Skid

    Fire Pump Skid

    Get Price Quote

    • Automation GradeAutomatic
    • FinishingGalvanised
    • OEM ServiceYes
    • Backup24X7
  • Portable Fire Pump

    Portable Fire Pump

    Get Price Quote

    A rapid and strong firefighting vehicle, totally independent from continuous water supply, paved roads and the prevailing infrastructure which normally determines the scene for an effective fire fighting operation: The IFEX FireHunter has been developed for the special requirements of wildland and forest fires and since has proven how effective it is fighting urban and industrial fires, too. With comparatively small amounts of water the high performance Dual Intruder cannons generate the impact to control or extinguish even large fires. So the IFEX FireHunter presents the ultimate solution for performing a fast and effective initial attack on structural, industrial, forest and wildland fires.
    ...more
  • Fire Hydrant Pump

    Fire Hydrant Pump

    70,000 /

    • Country of Origin220 to 380V
    • MaterialMild Steel
    • Frequency50 Hz
    • Working Pressure2.5 MPa
  • Fire Pump

    Fire Pump

    Get Price Quote

    Fire Pump, Fire Pip