Calibrators Dealers in Dahisar, Mumbai

(6 products available)
  • Premium
    Energy Meter Calibration Test Set (PCS ME 1.0)

    Energy Meter Calibration Test Set (PCS ME 1.0)

    Get Price Quote

    • Display TypeDigital
    • Frequency50Hz, 60Hz
    • Power0-6VDC, 12-18VDC
    • Driven TypeElectric
    • Temperature Range0-100°C, 100-200°C, 200-400°C
    • FeatureDurable, Heat Resistance, High Performance
    • Current TypeAC, DC
    • The Energy Meter Calibration Test Set (PCS ME 1.0) is a power calibration system with PCS ME 1.0 and EnergoEtalon™ software. The reference setup of the Energy Meter Calibration Test Set (PCS ME 1.0) provides high accuracy of measurements within an extended frequency range of 16-2500 Hz. The Energy Meter Calibration Test Set (PCS ME 1.0) is versatile in testing and calibrating the high-end measuring instruments, irrespective of AC or DC determination.
    ...more
    www
  • Calibrators

    Calibrators

    Get Price Quote

    Libratherm offers 4 and ½ digit mV Calibrator, which is suitable for simulation and measurement of thermocouple signals. It can be used to calibrate or cross check the calibration of temperature instruments. Some model also soureces (4-20)mA current for calibrating temperature and other process transmitters. Even transmitter output can also be measured accurately using the built in loop supply of 24VDC. For calibrating RTD based instruments a separate fixed and variable value resistance source is available.Applications :Measures temperatures in conjunction with a thermocouple.Calibration and testing of indicators and recorders Suitable for many routine field servicing and in house test/measuring unit to calibrate temperature indicator / controller.Mini Volt Calibrator MODEL : LC-02 RANGE : 0.00 “ 199.99 mV. & 0 “ 1999 mV ±1%FSD.POWER SUPPLY : Mains 240 VAC or 110 VAC Operated only MODES : Sink & Source OUTPUT : ADJ. Using Coarse and Fine PotentiometerRANGE SELECTION : Using Push SwitchWEIGHT : 2.0 kg ApproxResistor Calibrator for RTD Source onlyMODEL LC - 02OUTPUT ADJ. : 12 Fixed Points { -50, -10, 0, 10, 50, 100, 150, 200, 250, 300 & 350 OHMS} and Variable between each Ranges using PotentiometerACCURACY : ± 0.1% SIZE : 96 X 96 X 120
    ...more
  • Humidity Calibrator

    Humidity Calibrator

    Get Price Quote

    Humidity Calibrator, Hot Runner Temperature Control System
  • Signal Calibrator

    Signal Calibrator

    Get Price Quote

    Signal Calibrator, Programmable PID Temperature Controlle
  • Ultra Low Pressure Calibrator

    Ultra Low Pressure Calibrator

    Get Price Quote

    Ultra Low Pressure Calibrator, Paddle Flow Switch, Room Isolation Monito
  • Calibration Systems

    Calibration Systems

    Get Price Quote

    Calibration System
Filter by Locality